GAS COOKTOP INSTALLATION INSTRUCTIONS
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
GAS COOKTOP
Flexible Connector
Wall Oven Cabinet
1. Wall Outlet
Location
NOTE: If an outlet
is not available,
have one installed
by a qualified
technician.
CL of unit
2. Installation
Insert the cooktop into the countertop opening.
Note: After inserting the cooktop into the
countertop opening, make sure the unit is sitting
on the metal flange around the top of the burner
box. Cooktop must not sit on the porcelain top.
Avoid cutting an oversized hole in the countertop.
Manifold Pipe
Cabinet sides or
filler panel
12" (30.5 cm)
8"
(20.3 cm)
10"
(25.4 cm)
Recommended
area for 120V
grounded outlet
on rear wall
22"
(55.9 cm)
CL of unit
Figure 3
18" (45.7 cm) Max.
6½"
5"
(16.5 cm)
(12.7 cm)
Flare
Min.
Union
Flare
Union
3. Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
To clamp down, insert the bracket with the offset side
of the angle into the slots on each side of the unit. The
thumb screw should then be run through the bracket, up
against the bottom of the counter. Tighten until the unit
draws down.
Cooktop
Angle Bracket
5
4" (10.2 cm)
120V/60Hz
Grounded
Right Side
Outlet
of Cabinet
Pressure
Regulator
Manual Shutoff Valve
(To be accessible for shut-off
valve operation)
Countertop
Thumb Screw