Suggestions And Precautions For The Efficient Use Of The Charger - Hitachi WH 14DMR Technical Data And Service Manual

Cordless impact driver/wrench
Table of Contents

Advertisement

(2) Effects of low ambient temperatures
The tightening torque required may be reduced at low ambient temperatures or under the influence of grease
and different torque coefficients (dependent on manufacturing and finishing processes, and specified by bolt
manufacturers).
(3) Different bolt diameter
Differences in bolt diameter will cause variation of the required levels of tightening torque. Generally speaking,
tightening torque is higher for large bolts.
(4) Different materials being tightened
When a bolt is tightened into a soft material such as aluminum, plastic, wood, etc., the tightening torque is
considerably less than when the bolt is tightened into a hard material such as steel.
(5) Different tightening conditions
The tightening torque may vary in accordance with bolt torque coefficient (dependent on manufacturing
process, and specified by bolt manufacturers), bolt grade and bolt length, even though the dimensions of the
bolts are the same. Tightening torque may also vary depending on the surface finishing state of tightening
materials (steel, aluminum, etc.), and materials to be tightened. In addition, if there is seal packing, clearance,
etc. between tightening materials, the tightening torque is decreased.
(6) Wear and looseness of the socket
With extended use, the hexagonal portion of the socket which is fitted to the head of the bolt or drill bit, and/or
hexagonal portion of the driver chuck which is fitted onto the anvil in the main body will become worn and
loose. Wear and looseness will cause a proportionate loss of tightening torque.
In addition, use of an incorrect size socket (slightly larger than the bolt being tightened) will also result in
decreased torque.
(7) Bolt and nut rotate together
Tightening torque that can be achieved will be considerably decreased if the bolt and nut rotate together
during the tightening operation. The customer should be advised to carefully observe the operation and
ensure this does not occur.

8-4. Suggestions and Precautions for the Efficient Use of the Charger

(1) Batteries may not be rechargeable immediately after use
If the storage batteries are exposed to direct sunshine for an extended period, or if the temperature of the
batteries is 40 ûC (104 ûF) or higher immediately after they have been used in the tool, the pilot lamp may not
light up when the batteries are connected to the Model UC 14YFA, UC 24YFA or UC 18YG Charger. This is
because the built-in thermostat functions to stop the charging when the temperature of the storage batteries
reach 40 ûC (104 ûF) or more. In such a case, the customer should be advised to place the batteries in a
shaded area with a good airflow, and allow sufficient cooling before recharging.
This phenomenon is common to all existing batteries which employ temperature sensitive overcharge devices.
The cooling time required before charging can be accomplished varies from a few minutes to about 30
minutes, depending on the load, duration of use, and ambient temperature.
--- 26 ---

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wr 14dmrWr 18dmr

Table of Contents