5.3.4
Range of the measurement field
The maximum distance for contour measurement at a reflectance factor of 80% (white
gipsum) is 50 m.
Reflectors
White gypsum
Writing paper
Gray carton
Black corduroy
a = Detection zone
b = Measurement field
Fig. 5.3-2:
5.3.5
Required Detection Zone Additions Z
The SIMATIC FS600 Laser Scanner is equipped with a selectable dust algorithm to
ensure optimum freedom from interference.
The following detection zone additions must be taken into account:
Addition Z
suppression is deactivated
Addition Z
suppression
is activated
Activation and deactivation of the function is performed by SIMATIC FS600
Parameterization Software LS4soft.
34
Remission in %
a
Detection of objects depending on the reflectance factor. The reference
point of the distance measurement is the axis of the rotating mirror.
if dust
SM
if dust
SM
83 mm
83 mm (for a detection zone size < 3.5 m)
100 mm (for a detection zone size > 3.5 m)
b
15
Distance in m