Jacuzzi J?SN180F Installation And Operation Manual

Jacuzzi J?SN180F Installation And Operation Manual

Direct vent tankless water heater
Hide thumbs Also See for J?SN180F:

Advertisement

Signature Tankless Water Heaters 
J‐SN180F 
J‐SP180F 
J‐SN199F 
J‐SP199F 
Read this Manual 
This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper 
opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.   
Instruc ons on proper installa on and regular maintenance of the water heater should be followed to properly 
operate the water heater and to maintain the warranty. 
Read all of the instruc ons thoroughly before installing or opera ng this water heater. 
WARNING
—  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance. 
—  WHAT TO DO IF YOU SMELL GAS 
• Do not try to light any appliance. 
• Do not touch any electrical switch; do not use any phone in your building. 
• Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's instruc ons. 
• If you cannot reach your gas supplier, call the fire department. 
—  Installa on and service must be performed by a licensed professional. 
This en re manual must be le  for the consumer.  The consumer must read and  
refer to this manual for proper opera on and to maintain the water heater. 
ANS Z21.10.3  ● CSA 4.3 
If the informa on in these instruc ons is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death. 
Direct Vent Tankless Water Heater 
Installa on and Opera on Manual 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the J?SN180F and is the answer not in the manual?

Questions and answers

Summary of Contents for Jacuzzi J?SN180F

  • Page 1 Direct Vent Tankless Water Heater  Installa on and Opera on Manual  Signature Tankless Water Heaters  J‐SN180F  J‐SP180F  J‐SN199F  J‐SP199F  ANS Z21.10.3  ● CSA 4.3  Read this Manual  This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper  opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.    Instruc ons on proper installa on and regular maintenance of the water heater should be followed to properly  operate the water heater and to maintain the warranty.  Read all of the instruc ons thoroughly before installing or opera ng this water heater.  If the informa on in these instruc ons is not followed exactly, a fire or explosion  WARNING may result causing property damage, personal injury or death.  —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other  appliance.  —  WHAT TO DO IF YOU SMELL GAS  • Do not try to light any appliance.  • Do not touch any electrical switch; do not use any phone in your building. ...
  • Page 2: Table Of Contents

    State Regula ons ........... 39    Adjust for High Al tude ........ 19  Replacement Parts .......... 40    Checklist for Gas and Electricity ...... 19  Consumer Warranty  .......... 41    Installa on of Temperature Controller ... 20    Final Checklist .......... 21  Jacuzzi some mes shares customer contact informa on with businesses that we believe provide products or  services that may be useful to you.  By providing this informa on, you agree that we can share your contact  informa on for this purpose.  If you prefer not to have your informa on shared with these businesses, please  contact customer service and ask not to have your informa on shared.  We will however, con nue to contact  you with informa on relevant to the product(s) you registered and/or you account with us.  Important Safety Informa on  Safety Defini ons  This is the safety alert symbol.  This symbol alerts you to poten al hazards that can kill or hurt you      and others. Indicates an imminently hazardous situa on which, if not avoided, will result in death or ...
  • Page 3: Safety Behaviors And Prac Ces For The Consumer And Installer

        Safety Behaviors and Prac ces for the Consumer and Installer  WARNING • • To protect yourself from harm, before performing  Any altera on to the appliance or its controls can  maintenance:  be dangerous and will void the warranty.  ◊ Turn off the electrical power supply by  • Always check the water temperature before  unplugging the power cord or by turning off the  entering a shower or bath.  electricity at the circuit breaker.  (The  • Do not use this appliance if any part has been  temperature controller does not control the  under water.  Immediately call a licensed  electrical power.)  professional to inspect the appliance and to replace  ◊ Turn off the gas at the manual gas valve,  any part of the control system and any gas control  usually located immediately below the water  which has been under water.  heater.  • ◊ Turn off the incoming water supply.  This can  Do not use subs tute materials.  Use only parts  cer fied with the appliance.  be done at the isola on valve immediately  below the water heater or by turning off the  •...
  • Page 4: Installa On Instruc Ons

      Installa on Instruc ons  Installer Qualifica ons  General Instruc ons  A licensed professional should install the appliance,  DO NOT  inspect it, and leak test it before use.  The warranty  • Do not install the appliance outdoors.  will be voided due to improper installa on.  • Do not install the appliance in an area where water  The installer should have skills such as:  leakage of the unit or connec ons will result in  • gas sizing  damage to the area adjacent to the appliance or to  • connec ng gas lines, water lines, valves,  lower floors of the structure.  When such loca ons  electricity,   cannot be avoided, it is recommended that a  • suitable drain pan, adequately drained, be installed  knowledge of applicable na onal, state, and  under the appliance.  The pan must not restrict  local codes.  combus on air flow.  • installing ven ng through a wall or roof  •...
  • Page 5: Prepare For Installa On

      Prepare for Installa on  • You must follow the installa on instruc ons and  Parts included  those in Care and Maintenance for adequate  combus on air intake and exhaust.  • Tankless water heater  INFORMATION  • If a water heater is installed in a closed water  Tools needed  supply system, such as one having a backflow  preventer in the cold water supply line, means  • • Pipe wrenches (2)  Wire cu ers  shall be provided to control thermal expansion.  • • Adjustable pliers  Gloves  Contact the water supplier or local plumbing  inspector on how to control thermal expansion.  • • Screwdrivers (2)  Safety glasses  • Should overhea ng occur or the gas supply fail to  Tools that might be needed ...
  • Page 6: Determine Installa On Loca On

      Determine Installa on Loca on  You must ensure that clearances will be met and that  Environment  the vent length will be within required limits.   Air surrounding the water heater, ven ng, and vent  Consider the installa on environment, water quality,  termina on(s) is used for combus on and must be  and need for freeze protec on.  Requirements for the  free of any compounds that cause corrosion of  gas line, water lines, electrical connec on, and  internal components.  These include corrosive  condensate disposal can be found in their respec ve  compounds that are found in aerosol sprays,  installa on sec ons of this manual.  detergents, bleaches, cleaning solvents, oil based  paints/ varnishes, and refrigerants.  The air in beauty  shops, dry cleaning stores, photo processing labs, and  Water Quality  storage areas for pool supplies o en contains these  Considera on of care for your water heater should   compounds.  Therefore it is recommended that  include evalua on of water quality.    outdoor models be used for these loca ons where  possible.  Water that contains chemicals exceeding the levels ...
  • Page 7   Vent Termina on Clearances  You must install a vent termina on to bring in combus on air and expel exhaust.  TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED AIR SUPPLY INLET  CLOSED OPERABLE VENT TERMINAL  AREA WHERE TERMINAL  IS NOT PERMITTTED  Ref  US Installa ons  Descrip on  Clearance above grade (including an cipated snow line), veranda,  A  12 inches (30 cm)  porch, deck, or balcony ...
  • Page 8   Addi onal Clearances  Check on whether local codes supersede these clearances.  • Avoid termina on loca ons near a dryer vent.  • Avoid termina on loca ons near commercial cooking exhaust.  • You must install a vent termina on at least 12 inches from the ground  60" (1.52 m) ver cally  between terminals  (0.91 m) to ven lated or  unven lated soffit or eve  36" vent; or to a deck or porch  12" (0.30 m ) to an  inside corner  12" (0.61 m) to wall or parapet  24" (0.30 m) between   terminals at same  level  INSIDE CORNER   (1.52 m) between   60" terminals at  different levels ...
  • Page 9   Unit Clearances  Maximum Vent Length  1.  Determine the number of 90 degree elbows in  the vent system.  (Two 45 degree elbows count as  to top one 90 degree elbow.)  2.  Refer to the table to find the maximum vent  length based on the number of elbows.  3.  Adjust switch No. 1 in the SW1 DIP switch if  required by the applicable note.   to front Number of  Maximum vent length  90° Elbows  to side 0  41   (12.5 m) 1  1  35   (10.7 m) 2  2  29   (8.8 m) 3  3  23   (7.0 m) 4  4  17   (5.2 m) 4  5  11   (3.4 m) 4  to floor/ground 6 ...
  • Page 10   Freeze Protec on  Make sure that in case of freezing weather that the  water heater and its water lines are protected to  prevent freezing.  Damage due to freezing is not  covered by the warranty.  Loss of freeze protec on may result in water damage  from a burst heat exchanger or water lines.    With electrical power supplied, the water heater will  not freeze when the outside air temperature is as cold  as –22°F (‐30°C) for indoor models or is as cold as –4° F (‐20°C) for outdoor models, when protected from  direct wind exposure.  Because of the “wind‐chill”  effect, any wind or circula on of the air on the unit  will reduce its ability to freeze protect.  The unit may be drained manually.  However, it is  highly recommended that:  • drain down solenoid valves are installed that will  automa cally drain the unit if power is lost.    These are available in a kit, J‐A105.  • a surge protector with terminals is installed which  allows the solenoid valves to operate if the unit is  disabled due to a diagnos c code.  This is  available as J‐A106.  In addi on, the solenoid valves should be connected  electrically to a surge protector with terminals.  This  allows the solenoid valves to operate if the water  heater is disabled due to a diagnos c code.    The freeze protec on features will not prevent the  external piping from freezing.  It is recommended that  hot and cold water pipes are insulated.  Pipe cover ...
  • Page 11: Checklist To Determine Installa On Loca On

      Mount to Wall  Checklist to Determine Installa on  Loca on  □  The water heater is not exposed to corrosive  compounds in the air.  □  The water heater loca on complies with the  wall installa on  clearances.  brackets  □  The planned ven ng will not exceed the  maximum length for the number of elbows used.    □  The planned ven ng termina on/air intake  loca on meets the clearances.  □  The water supply does not contain chemicals or  exceed total hardness that will damage the heat  1.  Iden fy the installa on loca on and confirm that  exchanger.  the installa on will meet all required clearances.  □   A standard 3 prong 120 VAC, 60 Hz properly  2. ...
  • Page 12: Installa On Of Ven Ng

      Installa on of Ven ng  Install the correct ven ng for your model according to the ven ng manufacturer’s instruc ons and the guide‐ lines below.  J‐SN180F, J‐SP180F, J‐SN199F, J‐SP199F  Listed and Tested Vent Products for  Manufacturer  Product  Telephone  Fax  Contact  Ubbink  Rolux Vent System   888‐835‐9320  678‐829‐1666  www.jacuzzi.com/tankless  Heat‐Fab  Saf‐T Vent SC system  custsvc@heat‐fab.com,  800‐772‐0739  413‐863‐4803  www.hea ab.com  Metal‐Fab  Corr/Guard Vent/Air Intake  info@mtlfab.com,  800‐835‐2830  316‐943‐2717  System  www.metal‐fabinc.com    Ven ng Guidelines       ...
  • Page 13   Flue Installa on    Install the ven ng termina on according to the diagrams and instruc ons below.  Horizontal Termina on without using the Condensate Collector  WARNING * The condensate collector must be used in  horizontal termina ons if a ver cal rise in  If the condensate collector is not used, the drain pipe must  the vent system exceeds 5 .  be capped to prevent exhaust gases and condensate from  entering the building.  The cap is supplied on the appliance.  Maximum Height *  Regions of cold climate will create more  5 feet (1.52 m)  condensate in the vent system.  The  condensate collector should be used in  cold climates.  If more than one elbow is used in the  ver cal sec on the condensate collector  must be used.  Horizontal Termina on using the  Ver cal Termina on   Condensate Collector  (condensate collector must be used in all installa ons)  Condensate  Condensate ...
  • Page 14: Installa On Of Condensate Trap

      Installa on of Condensate Trap  INFORMATION  Condensate forma on can occur in high efficiency  direct vent appliances.  Without proper drainage  • Signature water heaters have an integrated  condensate will damage the heat exchanger.    condensate collector.  To prevent condensate damage follow these  • A condensate trap is available, J‐SV016.    instruc ons.  • Regions of cold climate will create more  DO NOT  condensate in the vent system.  The condensate  • collector should be used in cold climates.  Do not allow condensate to enter the water  heater.  • The condensate drain pipe should be as short as  • possible and have a downward pitch.  Do not use PVC, CPVC, ABS or galvanized material  to vent this appliance.  • Do not connect the condensate drain pipe directly  to the rain sewer.  • Do not connect the condensate drain line with an  air condi oning evaporator coil drain.  MUST DO  • Use only vent that is approved and iden fied as  acceptable for your par cular model. ...
  • Page 15: Installa On Of Plumbing

    DO NOT  pressure relief valve for this appliance.  However,  • Do not plug the relief valve and do not install any  local codes may require a combina on  reducing fi ngs or other restric ons in the relief  temperature and pressure relief valve.  line.  The relief line should allow for complete  Isola on Valves    drainage of the valve and the line. Jacuzzi recommends installa on of isola on valves on  • Do not place any other type valve or shut off  the cold and hot water lines.  Isola on valves provide  device between the relief valve and the water  the ability to isolate the water heater from the    heater. structure’s plumbing and allow quick access to flush  MUST DO  the heat exchanger.    • The relief valve must comply with the standard for  Relief Valves and Automa c Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and /or the ...
  • Page 16   Piping Diagram for Basic Installa on    Rinnai Water Heater   Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) 3/4" Hot Water Supply Line For Building Fixtures This is not an engineered drawing.
  • Page 17: Checklist For Plumbing

      Installa on of Gas Supply  Connect Water Heater to Water Supply  WARNING 1.  If you are not knowledgeable or qualified to  Water connec ons to the tankless water heater  install gas lines or connec ons, then contact  a  should follow all state and local plumbing codes.  licensed professional to install the gas supply.  If this is a standard installa on, refer to the Piping  2.  Turn off 120v power supply.  Diagram for Basic Installa on.  3.  Turn off the gas.  1.  Plumb water supply to the tankless water heater  on the 3/4” MNPT connec on at the bo om of  4.  Gas is flammable.  Do not smoke or provide other  the unit marked “Water Inlet”, which is the cold  igni on sources while working with gas.  water supply.  5.  Do not turn on the water heater or gas un l all  2.  Plumb the building hot water supply to the 3/4”  fumes are gone.  MSPT connec on marked “Water Outlet”, which  is the hot water supply. ...
  • Page 18 •   Any compound used on the threaded joint of the  Pipe Sizing Table ‐ Natural Gas  gas piping shall be a type which resists the ac on  Schedule 40 Metallic Pipe  of liquefied petroleum gas (propane / LPG).  Inlet Pressure:  less than 2 psi (55 inches W.C.)  • The gas supply line shall be gas  ght, sized, and so  Pressure Drop:  0.3 inches W.C.  installed as to provide a supply of gas sufficient to  Specific Gravity:  0.60  meet the maximum demand of the heater and all  cubic feet per hour  other gas consuming appliances at the loca on  without loss of pressure.  Pipe Size (inches)  Length   INFORMATION   3/4  1  1 1/4  1 1/2  • Refer to an approved pipe sizing chart if in doubt  10  273  514  1060  1580  about the size of the gas line.  20  188 ...
  • Page 19: Connect Electricity

      Connect Electricity  Adjust for High Al tude  On the DIP switch, set  switches 2 and 3 to the values  shown in table below for your al tude.  The default  WARNING se ng for the appliance is 0‐2000   (0‐610 m) with  switches No. 2 and No. 3 in the OFF posi on.  Do not use an extension cord or an adapter plug with  When the DIP switch is adjusted, it is not necessary to  this appliance.  adjust the gas pressure se ng for high al tude.  The water heater must be electrically grounded in  accordance with local codes and ordinances or, in the  Switch  Switch  absence of local codes, in accordance with the  Al tude  No. 2  No. 3  Na onal Electrical Code, ANSI/NFPA No. 70.  0‐2000   (0‐610 m)  OFF  OFF  This water heater is equipped with a three‐prong  (grounding) plug for your protec on against shock  2001‐5200   (610‐1585 m)  OFF  ON ...
  • Page 20: Installa On Of Temperature Controller

      Installa on of Temperature  Controller  Moun ng the Controller  1.  Make three holes in the wall as shown.  WARNING Outline of Remote Turn the power off.  Do not a empt to connect the  temperature controllers with the power on.  Although  securing screw the controller is a low voltage device, there is 120 volt  1-21/32" poten al next to the temperature controller  wiring hole connec ons inside the unit.    3-5/16" Do not connect the temperature controller to the  securing screw 120VAC terminals provided for the op onal solenoid  drain valves.    2.  Run the cable between the controller and the  water heater or the controller and another  Indoor models have their controller built into the  controller.  front panel.  Addi onal controllers can be installed.  3.  Remove the face plate from the temperature  controller using a screwdriver. ...
  • Page 21: Final Checklist

      Final Checklist  □  Confirm that the gas inlet pressure is within  limits.  □  The water heater is not subject to corrosive  □  Confirm that the water heater is rated for the gas  compounds in the air.  type supplied.  □  The water supply does not contain chemicals or  □  Confirm that the electricity is supplied from a 120  exceeds total hardness that will damage the heat  VAC, 60 Hz power source, is in a properly  exchanger.  grounded circuit, and  turned on.  □  Clearances from the water heater unit are met.   □  Verify the temperature controller is func oning  □  Clearances from the vent termina on / air intake  properly.  are met.  □  Verify that switches No. 2 and No. 3 in the SW1  □  Ensure you have used the correct ven ng  DIP switch is set correctly for your al tude.  products for the model installed and that you  □  Verify the system is func oning correctly by  have completely followed the ven ng ...
  • Page 22: Technical Data

      Technical Data  Specifica ons  Model  J‐SN180F, J‐SP180F  J‐SN199F, J‐SP199F  9,900 (NG)  Minimum Gas Consump on Btu/h   10,300 (LPG)  199,000 (NG)  Maximum Gas Consump on Btu/h   180,000  190,000 (LP)  0.26 ‐ 7.5 GPM  0.26 ‐ 9.4 GPM  Hot water capacity (Min ‐ Max) *  (1 ‐ 28.5 L/min)  (1 ‐ 35.5 L/min)  Temperature Se ng (no controller)   120° F (49° C)  or 140° F (60° C)   Maximum Temp Se ng (residen al)   ° Selectable at 120  F (49° C) or at 140° F (60° C)   see Temperature Ranges for more informa on  Minimum Temperature Se ng   98° F (37° C)  Weight   51 lb (23 kg)  53 lb (24 kg)  Energy Factor  0.82 ...
  • Page 23: Dimensions

      Dimensions   DIM  DESCRIPTION  in (mm)  A  Width  14 (355.6)  B  Depth *  9.6 (244.5)  C  Height ‐ Unit  22.9 (582)  D  Height ‐ with brackets  25.5 (648.2)  E  Hot Water Outlet ‐ from wall *  3.6 (91)  F  Hot Water Outlet ‐ from center  4.3 (110)  G  Cold Water Inlet ‐ from wall *  2.8 (70)  H  Cold Water Inlet ‐ from center  1.1 (27)  I  Gas Connec on ‐ from wall *  3.9 (99)  J  Gas Connec on ‐ from center  3.5 (89)  From base to gas connec on  1.6 (40) ...
  • Page 24   Informa on for the Service Provider  Pressure Drop Curve   Water Flow (gpm)  Outlet Flow Data   J‐SN199F  J‐SP199F  J‐SN180F  J‐SP180F  delta T ‐ Temperature Rise (°F)  24  J‐S180F/J‐S199F ...
  • Page 25: Ladder Diagram

        Ladder Diagram                                      J‐S180F/J‐S199F  25 ...
  • Page 26: Opera On Instruc Ons

      Direct Vent Tankless Water Heater  Opera on Instruc ons  Signature Tankless Water Heaters  J‐SN180F  J‐SP180F  J‐SN199F  J‐SP199F  Important Facts about your Water Heater  Thank you for purchasing a Jacuzzi Tankless Water Heater.  For proper opera on and  safety, it is important to follow the instruc ons and adhere to the safety precau ons.    Read all of the instruc ons and the warranty thoroughly before opera ng this water  heater.  Keep this manual in a safe place.  If the informa on in these instruc ons is not followed exactly, a fire or  WARNING explosion may result causing property damage, personal injury or death.  —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  other appliance.  —  WHAT TO DO IF YOU SMELL GAS  • Do not try to light any appliance.  • Do not touch any electrical switch; do not use any phone in your building.  • Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s  instruc ons.  • If you cannot reach your gas supplier, call the fire department. ...
  • Page 27: Consumer Opera On Guidelines For The Safe Opera On Of Your Water Heater

      Consumer Opera on Guidelines for the Safe Opera on of your Water Heater     FOR YOUR SAFETY READ BEFORE OPERATING    If you do not follow these instruc ons exactly, a fire or explosion  WARNING may result causing property damage, personal injury or loss of life.  A.  This appliance does not have a pilot.  It is  neighbor’s phone.  Follow the gas supplier’s  equipped with an igni on device which  instruc ons.  automa cally lights the burner.  Do not try to light  • If you cannot reach your gas supplier, call the  the burner by hand.  fire department.  B.  BEFORE OPERATING smell all around the  C.  Use only your hand to push in or turn the gas  appliance area for gas.  Be sure to smell next to  control knob.  Never use tools.  If the knob will not  the floor because some gas is heavier than air and  push in or turn by hand, do not try to repair it, call  will se le on the floor.  a licensed professional.  Force or a empted repair    WHAT TO DO IF YOU SMELL GAS  may result in a fire or explosion.  •...
  • Page 28: Opera Ng Instruc Ons

      Opera ng Instruc ons  J‐C100 Temperature Controller  The J‐C100 controller is the standard temperature controller that is supplied with the water heater.  On indoor  models it is integrated into the front panel.    Dimensions (inches):  3.5 W x 4.75 H x 0.75 D  Opera on Indicator  Priority Indicator  Temperature Display  Priority Bu on  Temperature Selec on  ON/OFF Bu on  J‐C200 Spa Controller  The J‐C200 controller is water resistant.  Avoid splashing the controller.  NOTICE  Dimensions (inches):  8.0 W x 4.125 H x 0.875 D  In Use  Temperature  Bath Fill Indicator  Indicator  Display  Priority Bu on  and Indicator  ON/OFF Bu on  Bath Fill  Bath Fill Call  Power Save  J-C200 Use caution when adjusting water temperature. Temperature ...
  • Page 29: How To Set The Temperature

      How to Set the Temperature   This water heater requires a minimum flow rate to operate.  This rate can be found on the specifica on page in  this manual.  In some cases when you are not ge ng hot water or if the water alternates between hot and cold,  it is due to the water flow being below or close to the minimum flow rate.  Increasing the flow rate should  resolve these problems in these cases.  If you are experiencing issues with higher temperature se ngs, then reduce the temperature se ng.  Selec ng a  temperature closer to that which is actually used at the faucet will increase the amount of hot water being  delivered to the faucet, due to less cold water mixing at the fixture.  Hot water can be dangerous, especially for infants or children, the elderly,            DANGER  or infirm.  There is hot water scald poten al if the thermostat is set too high.  Water temperatures over 125° F (52° C) can cause severe burns or scalding  resul ng in death.  Hot water can cause first degree burns with exposure for as li le as:    3 seconds at 140° F (60° C)    20 seconds at 130° F (54° C)    8 minutes at 120° F (49° C)  Test the temperature of the water before placing a child in the bath or  shower.  Do not leave a child or an infirm person in the bath unsupervised.  1.  If the water heater is off, press  While any hot water is being provided,  NOTICE  the ON/OFF bu on to turn on.  the temperature se ng can only be  adjusted between 98° F and 110° F. ...
  • Page 30   Temperatures Available with a Controller   The water heater can deliver water at only one temperature se ng at a  me.  The available temperatures are  provided below.  A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.  To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” bu on  for 5 seconds while the water heater is OFF.  Temperature Se ngs Available    *  Fahrenheit °F  98  100  102  104  106  108  110  115  120  125  130  135  140  Celsius  °C  37  38  39  40  41  42  43  46  49  52  54  57  ...
  • Page 31: Using The Bath Fill Func On

        Using the Bath Fill Func on                        Overview  Se ng the Water Volume and Temperature   This func on is exclusive to the J‐C200 temperature  The default volume is set to 25 gallons.  The volume  controller.  The bath fill func on allows the consumer  can be set between 10 and 120 gallons.  to fill a tub with a preset volume of water at a preset  temperature.  This is done by pressing the bath fill  bu on on the J‐C200 controller while no hot water is  1.  Press the “Priority” bu on on  flowing and then opening only the hot water tap.  The  the temperature controller.   water heater will stop the hot water flow when the  The green Priority light will glow  preset volume has been reached.  The hot water tap  indica ng that this controller is  should then be closed and the bath fill bu on  controlling the temperature and ...
  • Page 32     Using the Bath Fill Func on                        Filling the Tub   1.  Press the “Bath Fill” bu on once.   To stop the water flow during the Bath Fill  NOTICE  The bu on will illuminate, and a  Bath Fill func on, press the “Bath Fill” bu on.  The  To Stop  tone will sound.  bu on will flash and the voice prompt will  the Bath  announce, “Hot water is not available.   2.  The voice prompt will announce  Fill  Turn off all hot water taps and push the  “The hot water system is ready.   Before it  Bath Fill bu on.”  Follow the voice ...
  • Page 33: Diagnos C Codes

      Diagnos c Codes  This water heater is designed with diagnos c codes to help you determine poten al opera on concerns .  To Display Diagnos c Informa on   To display the most recent diagnos c codes press and hold the “On/Off” bu on for 2 seconds on the J‐C100  controller.  While holding the “On/Off” bu on press the up bu on.  The last 9 diagnos c codes will flash one a er the  other.  To exit this mode press the “On/Off” and up bu on as before.  To display the water flow through the water heater press and hold the up bu on for 2 seconds and without releasing  the up bu on press the “On/Off” bu on.   To display the outlet water temperature press and hold the down bu on for 2 seconds and without releasing the  down bu on press the “On/Off” bu on.    Diagnos c Codes and Remedies   Some of the checks below should be done by a licensed professional.  Consumers  WARNING should never a empt any ac on that they are not qualified to perform.  Code  Defini on ...
  • Page 34   Code  Defini on    Remedy    Check for restric ons in air flow around unit and vent terminal.  Check gas type of unit and ensure it matches gas type being used.  Check for low water flow in a circula ng system causing short‐cycling.  Ensure dip switches are set to the proper posi on.  Check for foreign materials in combus on chamber and/or exhaust piping.  licensed  Check heat exchanger for cracks and/or separa ons.  14   Thermal Fuse   professional  Check heat exchanger surface for hot spots which indicate blockage due to scale build‐up.  Refer  only  to instruc ons in manual for flushing heat exchanger.  Hard water must be treated to prevent  scale build up or damage to the heat exchanger.  Measure resistance of safety circuit.  Ensure high fire and low fire manifold pressure is correct.  Check for improper conversion of product.    Check for restric ons in air flow around unit and vent terminal.  Over Temperature  licensed  Check for low water flow in a circula ng system causing short‐cycling.  16   Warning   professional  Check for foreign materials in combus on chamber and/or exhaust piping. ...
  • Page 35: Required Maintenance

      Required Maintenance  The appliance must be inspected annually by a licensed professional.  Repairs and maintenance should be per‐ formed by a licensed professional.  The licensed professional must verify proper opera on a er servicing.  WARNING To protect yourself from harm, before performing maintenance:  • Turn off the electrical power supply by unplugging the power cord or by turning off the electricity at the  circuit breaker.  (The temperature controller does not control the electrical power.)  • Turn off the gas at the manual gas valve, usually located immediately below the water heater.  • Turn off the incoming water supply.  This can be done at the isola on valve immediately below the water  heater or by turning off the water supply to the building.  WARNING Keep the appliance area clear and free from combus ble materials, gasoline, and other flammable vapors and  liquids.  The following maintenance items are required for the proper opera on of your water heater.  Cleaning  Temperature Controller  It is impera ve that control compartments, burners,  Use a so  damp cloth to clean the temperature  and circula ng air passageways of the appliance be  controller.  Do not use solvents.  kept clean.  Lime / Scale Build‐up  Clean as follows:  If you receive diagnos c code “LC”, refer to the  1.  Turn off and disconnect electrical power.  Allow to  procedure, Flushing the Heat Exchanger.  Refer to the  cool. ...
  • Page 36   Freeze Protec on  WARNING Make sure that in case of freezing weather that the  Tes ng the pressure relief valve should only be  water heater and its water lines are adequately  performed by a licensed professional.  Scalding hot  protected to prevent freezing.  Damage due to  water may be released under pressure.  freezing is not covered by the warranty.  Refer to the    Pressure Relief Valve:  sec on on Freeze Protec on. Winterizing  Operate the valve manually once a year.  In doing so,  it will be necessary to take precau ons with regard to  These recommenda ons are intended to suggest  the discharge of poten ally scalding hot water under  prac ces which are effec ve for winterizing the water  pressure.  Ensure discharge has a place to flow.   heater.  They should be used as a guide only.  No  Contact with your body or other property may cause  liability is assumed for any issues resul ng from the  damage or harm.  use of this informa on.    GAS  Visual Inspec on of Flame  Shut off the gas to the water heater.  It is generally ...
  • Page 37: Flushing The Heat Exchanger

      Flushing the Heat Exchanger  An “LC” or “00” diagnos c code indicates the unit is beginning to lime up and must be flushed.  Failure to flush  the appliance will cause damage to the heat exchanger.  Damage caused by lime build‐up is not covered by the  unit’s warranty.  A er flushing, reset the LC code by turning off the power to the unit and turning the power  back on.  1.  Disconnect electrical power to the water heater.  2.  Close the shutoff valves on both the hot water and  Pressure Regulator 3/4" Ball Valve cold water lines (V3 and V4).  Circulating Pump 3/4" Union 3.  Connect pump outlet hose (H1) to the cold water  line at service valve (V2).  Check Valve Boiler Drain Valve 4.  Connect drain hose (H3) to service valve (V1).  Pressure Relief Valve Solenoid Valve 5.  Pour 4 gallons of undiluted virgin, food grade, white  vinegar into pail.  6. ...
  • Page 38: Manual Draining Of The Water Heater

      Manual Draining of the Water Heater  To avoid burns, wait un l the equipment cools down before draining the water.  The  WARNING water in the appliance will remain hot a er it is turned off.  If the water heater is not going to be used during a period of possible freezing weather, it is recommended that  the water inside the water heater be drained.    To manually drain the water:  Water  1.  Shut off cold water supply and gas supply.  Hot water  Hot water  filter  2.  Turn off the temperature controller.  outlet  drain plug *  3.  Disconnect the power to the water heater.  4.  Remove the drain caps on both isola on valves and open both  valves above the caps (blue and red valve handles).  ‐OR‐  Open hot  water drain plug at the hot water outlet.  5.  Remove water filter to drain the cold water.  To resume normal opera on:  1.  Confirm that all water drain plugs are removed, that the gas supply  is turned off, and that all taps are closed.  2.  Screw in the water filter in the cold water inlet.  3.  Replace the drain caps and close both isola on valves. ‐OR‐  Screw  in the hot water drain plug.  Cold water ...
  • Page 39: State Regula Ons

      State Regula ons  NOTICE BEFORE INSTALLATION    This direct‐vent appliance must be installed by a licensed professional. If you are not properly trained, you  must not install this unit.  IMPORTANT:  In the State of Massachuse s (248 CMR 4.00 & 5.00)  For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or  structure used in whole or in part for residen al purposes, including those owned or operated by the  Commonwealth and where the side wall exhaust vent termina on is less than seven (7) feet above  finished grade in the area of the ven ng, including but not limited to decks and porches, the following  requirements shall be sa sfied:   1.  INSTALLATION OF CARBON MONOXIDE DETECTORS. At the  me of installa on of the side wall  horizontal vented gas fueled equipment, the installing plumber or gasfi er shall observe that a hard  wired carbon monoxide detector with an alarm and ba ery back‐up is installed on the floor level  where the gas equipment is to be installed. In addi on, the installing plumber or gasfi er shall  observe that a ba ery operated or hard wired carbon monoxide detector with an alarm is installed on  each addi onal level of the dwelling, building or structure served by the side wall horizontal vented  gas fueled equipment. It shall be the responsibility of the property owner to secure the services of  qualified licensed professionals for the installa on of hard wired carbon monoxide detectors  a.  In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl  space or an a c, the hard wired carbon monoxide detector with alarm and ba ery back‐up may  be installed on the next adjacent floor level. ...
  • Page 40: Replacement Parts

      Replacement Parts  The Technical Sheet which is located inside the front  cover of the water heater contains a complete  illustrated parts list.    Tech Sheet   Gas Control Assembly  Electrode / Flame Rod  Item No.   Gas Control Assembly  100  Electrode / Flame Rod Kit  116, 117  Fan Assembly / Motor  125  Heat Exchanger  143  Water Flow Servo & Sensor  401  Flow Sensor  NA  Fan Assembly / Motor  Heat Exchanger  Bypass‐Servo Assembly  403  Water Filter Assy  412  PC Board  700  Surge Protector  701  Ignitor  706  Thermal Fuse Harness  725  Bypass‐Servo Assembly  Water Flow Servo &  Flow Sensor  Water Filter Assy  Sensor ...
  • Page 41: Consumer Warranty

                            What is covered?  This Warranty covers any defects in materials or workmanship when the product is installed and operated  according to Jacuzzi wri en installa on instruc ons, subject to the terms within this Limited Warranty  document.  This Warranty applies only to products that are installed correctly.  Improper installa on may void  this Warranty.  Jacuzzi strongly suggests that you use a licensed professional who has a ended a product  knowledge class before installing this water heater.  This Warranty extends to the original purchaser and  subsequent owners, but only while the product remains at the site of the original installa on.  This Warranty  only extends through the first installa on of the product and terminates if the product is moved or reinstalled at  a new loca on.  How long does coverage last?  Period of Coverage (from date of purchase)  Item   Residen al Applica ons    Commercial Applica ons  Heat Exchanger  12 years *  5 years * ...
  • Page 42   How do I get service?  You must contact a state qualified/licensed professional for the repair of a product under this Warranty.  For the  name of a licensed professional please contact your place of purchase, visit the Jacuzzi website  (www.jacuzzi.com/tankless), call Jacuzzi at 1‐888‐835‐9320 or write to Jacuzzi at 103 Interna onal Drive,  Peachtree City, Georgia 30269.  Proof of purchase is required to obtain warranty service.  You may register this product within 30 days of  purchase or you may show proof of purchase with a dated sales receipt.  To register your tankless water heater,  .   please visit www.jacuzzi.com/tankless.  For those without internet access, please call 1‐888‐835‐9320 Receipt  of Registra on by Jacuzzi will cons tute proof‐of‐purchase for this product.  However, Registra on is not  necessary in order to validate this Warranty.  What is not covered?  This Warranty does not cover any failures or opera ng difficul es due to the following:  • accident, abuse, or misuse  • altera on  • misapplica on  • force majeure  • improper installa on (such as but not limited to inadequate water quality, condensate damage, improper  ven ng, incorrect gas type, incorrect gas or water pressure, or absence of a drain pan under the appliance)  • improper maintenance (such as but not limited to scale build‐up, freeze damage, or vent blockage)  •...
  • Page 84 J-S180F J-S199F U287-3188 (00) 060 00012 34364 9...

This manual is also suitable for:

J-sp180fJ-sn199fJ-sp199f

Table of Contents

Save PDF