1 Warning Caution: • Pb free solder has a higher melting point that standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a soldering iron with temperature control and adjust it to 750 ± 20°F (400 ± 10°C). In case of using high temperature solder- ing iron, please be careful not to heat too long.
Page 6
3.2. Trial Operation (after checking Troubleshooting Guide) 3.2.1. Assembly • Confirm if there is no gap between housing A and B by pinching lead wires. • There is no dust or deformation on battery terminals. • Confirm if there is no dirt when repairing. 3.2.2.
4 Disassembly and Assembly Instructions *To assemble the tool, start with 4-6 and proceed to 4-1 4.1. Removing the Housing 4.2. Removing the Assemblies...
Page 8
4.3. Removing the Motor Mounting Plate, Driving Shaft Assembly, and Fixa- tion Cover Assembly from the Motor Assembly 4.4. Removing the Fixation assembly, Driving shaft assembly, and Motor Mounting Plate...
Page 9
4.5. Removing the Motor Assembly, Switch Assembly, and Module assembly...
Page 10
4.6. Precautions When Assembling the Motor Assembly, Switch Assembly, and Module Assembly...
7 Exploded View and Replacement Parts List Model No. : EY75A2 Exploded View...
Page 14
Model No. : EY75A2 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks WEY75A2H3079 HOUSING AB SET 1 (for EUROPE) WEY75A2H3070 HOUSING AB SET 1 (for OCEANIA) WEY75A2K4058 FIXATION COVER ASSEMBLY WEY75A2L1067 DRIVING SHAFT ASSEMBLY WEY7546L0027 MOTOR MOUNTING PLATE ASSEMBLY...