215B
Legacyt Line Heat Pump
with Puronr Refrigerant
Size 1- - 1/2 - - 5 Nominal Tons
the environmentally sound refrigerant
Bryant heat pumps with Puronr refrigerant provide a collection of
features unmatched by any other family of equipment. The 215B
has been designed utilizing Bryant's Puron refrigerant. The
environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth's ozone layer.
As an Energy Starr Partner, Bryant Heating and Cooling has
determined that this product meets the Energy Starr guidelines for
energy efficiency. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING

FEATURES / BENEFITS

Efficiency
S 15 SEER/ 12.5 EER / 8.0 - - 9.0 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 69 dBA
S Sound levels as low as 68 dBA with accessory sound blanket
Comfort
S System supports Edger Thermidistatt or standard thermostat
controls
Reliability
S Puronr refrigerant - - environmentally sound, won't deplete the
ozone layer and low lifetime service cost.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S High pressure switch
S Loss of charge switch
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard standard
S Baked- -on powder paint
Applications
S Long- -line - - up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient cooling (down to - -20_F/- -28.9_C) with accessory
kit

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Legacy 215B and is the answer not in the manual?

Questions and answers

Summary of Contents for Bryant Legacy 215B

  • Page 1: Product Data

    S Balanced refrigeration system for maximum reliability Bryant heat pumps with Puronr refrigerant provide a collection of Durability features unmatched by any other family of equipment. The 215B DuraGuardt protection package: has been designed utilizing Bryant’s Puron refrigerant. The S Solid, durable sheet metal construction...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Grille Cooling Capacity Open Open Open Minor Family Series Variations Series 2=HP 5=15 SEER B=Puron N= 208 ---230 ---1 A = Standard 0=Not 0=Not 0=Not Legacy or 208/230 ---1 Defined Defined Defined Original Series ISO 9001:2000...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 018--- A 024--- A 030--- A 036--- A 042--- A 048--- A 060--- A Operating Weight lb (kg) 169 (76.7) 200 (90.8) 196 (88.9) 215 (97.5) 294 (113.4) (111.1) (117.9) Shipping Weight lb (kg) 207 (93.9) 345 (156.5) (105.7) (109.8)
  • Page 4: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{...
  • Page 5 Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack * Outdoor temperature sensor is an accessory for all Bryant electronic thermostats, except the non ---programmable air conditioner version and builder’s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 6 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW --- AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F / 12.8°C) (Over 80 ft. / 24.38 m) (Within 2 miles / 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Yes{...
  • Page 7 Accessory Description and Usage (Listed Alphabetically) - - CONTINUED 10. Outdoor Air Temperature Sensor 14. Sound Hood Designed for use with Bryant Thermostats listed in this Wraparound sound reducing cover for the compressor. Reduces the publication. This device enables the thermostat to display the sound level by about 2 dBA.
  • Page 8: Electrical Data

    ELECTRICAL DATA MAX LENGTH MIN WIRE OPER VOLTS* COMPR FUSE** ft (m))‡ SIZE† UNIT SIZE V/PH or BRK 60° C 75° C 60° C 75° C AMPS 018--- A 48.0 11.8 67 (20.4) 63 (19.2) 024--- A 58.3 12.8 16.5 48 (14.6) 45 (13.7) 030--- A...
  • Page 12 Wall...
  • Page 13 COMBINATION RATINGS High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647411 215BNA018****A †FX4DNF019 17,800 12.6 15.3 17,800 3.92 10,700 2.60 3647337 215BNA018****A FE4ANF002+UI 17,700 13.0 15.5 17,800 3.84 10,500 2.56...
  • Page 14: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647030 215BNA024****A CAP**2414A** 313*AV024045 23,400 12.5 15.0 24,000 3.84 14,500 2.64 3646435 215BNA024****A CAP**2414A** 315(A,J)AV036070 23,400 12.5 15.0 24,000...
  • Page 15 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647166 215BNA024****A CNPV*3117A** 355BAV042060 23,400 13.0 16.0 24,000 4.14 14,600 2.76 3646737 215BNA024****A CSPH*2412A** 353(A,B)AV036080 23,400 12.5 15.5 24,000...
  • Page 16 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3646867 215BNA030****A CAP**3621A** 355(A,C)AV042080 28,000 12.5 15.0 28,000 3.84 16,600 2.60 3646899 215BNA030****A CAP**3621A** 355(A,C)AV060080 28,000 12.5 15.0 28,200...
  • Page 17 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647209 215BNA030****A CNPV*3621A** 355BAV060100 27,800 12.5 15.0 28,000 3.78 16,600 2.58 3647297 215BNA030****A CNPV*3621A**+TDR 28,000 11.2 13.5 29,200 3.74...
  • Page 18 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647159 215BNA036****A CAP**3617A** 355BAV042060 33,600 12.0 14.0 34,600 3.68 21,200 2.54 3647241 215BNA036****A CAP**3617A**+TDR 33,600 11.0 13.0 35,800 3.62...
  • Page 19 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3646491 215BNA036****A CNPV*3617A** 315(A,J)AV048090 33,400 12.0 14.0 34,400 3.64 21,000 2.52 3646698 215BNA036****A CNPV*3617A** 353(A,B)AV036060 33,600 12.0 14.0 34,600...
  • Page 20 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647318 215BNA036****A CSPH*3612A**+TDR 33,600 11.0 13.0 35,800 3.72 22,400 2.52 3646742 215BNA036****A CSPH*4212A** 353(A,B)AV036080 34,200 12.0 14.5 35,000 3.88...
  • Page 21 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647131 215BNA042****A CAP**4824A** 313*AV060135 42,000 12.5 15.0 42,000 3.84 26,000 2.64 3646549 215BNA042****A CAP**4824A** 315(A,J)AV066135 41,500 12.5 15.0 42,000...
  • Page 22 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3646987 215BNA042****A CNPV*4324A** 355(A,C)AV060120 42,000 12.5 15.0 42,000 3.88 26,000 2.66 3647017 215BNA042****A CNPV*4324A** 355AAV042040 42,000 12.5 15.0 42,000...
  • Page 23 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647427 215BNA048****A FY5BNB060 47,000 11.5 13.5 47,000 3.74 30,000 2.56 3646749 215BNA048****A CAP**4817A** 353(A,B)AV048080 45,500 11.5 14.0 46,000 3.70...
  • Page 24 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3646951 215BNA048****A CNPH*6124A** 355(A,C)AV060100 46,500 12.0 14.0 46,000 3.76 29,200 2.58 3646985 215BNA048****A CNPH*6124A** 355(A,C)AV060120 46,500 12.0 14.5 45,500...
  • Page 25 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Model Furnace Cooling Coil Model Number SEER HSPF Ref. No. Number Model Number Capacity Capacity Capacity 3647261 215BNA060****A CAP**6024A**+TDR 55,500 11.5 13.5 56,500 3.68 36,000 2.60 3646634 215BNA060****A CAP**6025A** 359BAV060100 55,500 11.5 13.5 58,000 3.64...
  • Page 49 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 215B GENERAL 1- -1/2 TO 5 NOMINAL TONS System Description Fans Outdoor- -mounted, air- -cooled, split- -system heat pump unit — Condenser fan will be direct- -drive propeller type, suitable for ground or rooftop installation. Unit consists of a discharging air upward.
  • Page 50 Catalog No. PDS215B---01 E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/10 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.