Rob
March 13, 2025

Generator has been in storage as per instructions for four years, won’t start

1 comments:
Mr. Anderson
March 13, 2025

The Ryobi RIG2000 generator may not start after four years in storage due to several possible reasons:

1. Old or Stale Fuel – If fuel was left in the tank, it may have degraded, causing blockages in the fuel system. The fuel should be drained and replaced with fresh gasoline.

2. Clogged Carburetor – Stale fuel can leave deposits in the carburetor, preventing proper fuel flow. Cleaning or servicing the carburetor may be necessary.

3. Low or Dead Battery – If the generator has an electric start, the battery may have discharged over time and may need charging or replacement.

4. Fuel Valve Closed – The fuel valve may be in the closed position, preventing fuel from reaching the engine. It should be checked and opened if necessary.

5. Dirty or Faulty Spark Plug – A fouled or worn-out spark plug can prevent ignition. Inspect, clean, or replace the spark plug as needed.

6. Clogged Fuel Filter – A blocked fuel filter can restrict fuel flow, requiring cleaning or replacement.

7. Oil Level Too Low – The generator has a low oil shutdown feature that prevents it from starting if the oil level is too low. Checking and refilling the oil may resolve the issue.

8. Air Filter Blockage – A dirty air filter can limit airflow to the engine. Cleaning or replacing the air filter may be necessary.

Checking and addressing these issues should help restore the generator’s functionality.

This answer is automatically generated

Summary of Contents for Ryobi RIG2000

  • Page 1 ORIGINAL INSTRUCTIONS Digital Inverter Generator RIG2000...
  • Page 2 Important! It is essential that you read the instructions in this manual before operating this machine. Subject to technical modifications.
  • Page 3 Unpacking...
  • Page 4 Getting Started...
  • Page 5 Getting Started 15-30s...
  • Page 6 Getting Started O IL L O W S U R T O R T E C P R O...
  • Page 7 Safety ■ Use personal protective equipment. Always wear eye GENERAL SAFETY WARNINGS protection. Protective equipment such as dust mask, non- skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in ADDITIONAL SAFETY RULES electric shock, fi...
  • Page 8 Safety ■ Empty fuel tank, close fuel valve, and restrain the unit Fuel and its vapors are extremely from moving before transporting in a vehicle. fl ammable and explosive. Fire or explosion can cause severe burns or death. MAINTENANCE ■ Before storing the unit for an extended period of time, To reduce the risk of injury or damage, allow the engine to cool and drain fuel from the unit.
  • Page 9 Safety Go to page # Information Lock Unlock Wear safety gloves Dispose of replaceable part or accessory Parts or accessories sold separately Restart A sound is heard Disconnect from power outlet Use fuel stabilizer Waiting time...
  • Page 10 Overview Auto-idle...
  • Page 11 Operation...
  • Page 12 Operation Auto-idle Smart throttle switch With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned OFF or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load ln the OFF position, the smart throttle system does not operate.
  • Page 13 Operation AC Output Switch...
  • Page 14 Operation 15-30 mins 15-30s...
  • Page 15 Operation...
  • Page 16 Maintenance...
  • Page 17 Maintenance 5 min 5 min...
  • Page 18 Maintenance LO W SU RG EC TO PR OT...
  • Page 19 Maintenance...
  • Page 20 Maintenance...
  • Page 21 Maintenance O IL LO W SU RG TO R TE C P R O...
  • Page 22 PRODUCT SPECIFICATIONS Model RIG2000 Engine Engine Mode 158F Engine Type Single Overhead Cam (SOHC) Displacement 105.7 cc Cooling System Forced Air Compression Ratio 8.5:1 Starting System Recoil Ignition System T.C.I. Spark Plug NGK CR6HSA Oil capacity 0.4 L Fuel tank capacity 3.6L...
  • Page 23 WIRING DIAGRAM...

Table of Contents

Save PDF