Download Print this page

General Description - Mitsubishi Electric FR-A800 Safety Stop Function Instruction Manual

Safety stop function
Hide thumbs Also See for FR-A800:

Advertisement

1

GENERAL DESCRIPTION

Features
Mitsubishi FR-A800/F800 safety stop function prevents a drive from supplying rotational energy to motors. Dual
safety channels 'S1' and 'S2' cut off the gate-drive power for IGBT to turn off.
RESET
Emergency
stop button
Safety relay module
/ Safety programmable controller
WARNING
 Disconnecting the power to the gate driver by the safety stop function does not isolate electrically
between drive and motor. To avoid an electric shock hazard, disconnect power to the drive and verify
that the main circuit capacitor voltage is zero (across P and N terminals) before performing any work
on the motor (refer to your drive's
Standards
Mitsubishi FR-A800/F800 safety stop function meets the following directives and categories.
ISO13849-1:2008 Category 3/PLd
IEC62061:2005 / IEC61800-5-2:2007 / IEC61508 SIL2
IEC60204-1:2010 / IEC61800-5-2:2007 Stop category 0
WARNING
 The misuse of safety function leads to personal injury or death, property damage, or economic loss.
To ensure that the system complies fully with requirement of safety, make a system-level risk
assessment. Mitsubishi Electric Co. cannot assume responsibility for any system to comply with
safety directive.
2
GENERAL DESCRIPTION
SO
SOC
+24V
Fuse
PC
24VDC
S2
S1
SIC
SD
Fig.1 FR-A800/F800 safety stop function diagram
User Manual
FR-A800/F800
Logic
ASIC
CPU
for discharging time).
R/L1 S/L2 T/L3
IGBTs
Gate
Gate
Driver
Driver
G
G
U V W
M