BLAZE KING
PEGASUS 9703 GAS APPLIANCE
Owner's Installation and Operations Manual
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may re-
sult casing property damage, personal injury may
result.
-Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
-WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any
phone in your building.

Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.

If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Blaze King Industries
146
A Street
Walla Walla WA
99362
Ph# 1-509-522-2730
FX# 1-509-522-9803
OM-9703
PRODUCTS

SAVE THESE INSTRUCTIONS

MANUFACTURED BY
PAGE 1
Valley Comfort Systems Inc.
1290 Commercial Way
Penticton, BC
V2A 3H5
Ph# 1-250-493-7444
FX# 1-250-493-5833
Date Printed: Thursday, July 05, 2007
Revision Date: March 6, 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PEGASUS 9703 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blaze King PEGASUS 9703

  • Page 1: Save These Instructions

    BLAZE KING PRODUCTS PEGASUS 9703 GAS APPLIANCE Owner's Installation and Operations Manual SAVE THESE INSTRUCTIONS WARNING: If the information in these instructions are not followed exactly, a fire or explosion may re- sult casing property damage, personal injury may result.
  • Page 2 Dear Customer: Thank you for purchasing this Blaze King gas appliance. It is our goal to have every purchaser of a Blaze King stove be a satisfied customer. This owner’s manual explains the steps required to safely assemble, install, operate, and maintain your new appliance.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SPECIFICATIONS MODEL 9703 ......................4 SAFETY NOTICE ............................ 5 WARRANTY ............................6 WHITE MINERAL DEPOSITS......................... 7 COPY OF APPROVAL LABEL........................ 8 ELECTRICAL GROUNDING INSTRUCTIONS..................9 CAUTION ..............................9 PLANNING YOUR STOVE PLACEMENT .................... 10 Z 9723 INSERT KIT..........................11 AIR SHUTTER ADJUSTMENT ......................
  • Page 4: Specifications Model 9703

    SPECIFICATIONS - 9703 Gas Appliance Rating Natural Gas L P Gas Freestanding / Insert Freestanding / Insert Input Rating (BTU/hr) 0-610m (0-2000 ft.) ALT 44,000 42,000 Orifice Size (DMS) 610m #48 ( & #33 & #52 ( Front) (Back) (Front) Back) Input Rating (Btu/hr) 610-1370 m (2000-4500 ft) ALT 41,000...
  • Page 5: Safety Notice

    SAFETY NOTICE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE, OR EXPLOSION MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION REQUIREMENTS IN YOUR AREA. PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW APPLIANCE.
  • Page 6: Warranty

    BLAZE KING LIMITED LIFETIME WARRANTY Gas stoves manufactured by Blaze King Industries and/or Valley Comfort Systems Inc. are covered by a limited lifetime warranty against manufacturers defects in material and workmanship. Details of this comprehensive warranty program are outlined below. In addition to the terms outlined for the limited lifetime warranty, our products carry a 5 year warranty which covers mechanical and electrical components including labor costs outlined below.
  • Page 7: White Mineral Deposits

    BLAZE KING LIMITED LIFETIME WARRANTY Legal Rights of Purchaser: This warranty gives you specific legal rights and you may have other rights that vary from state to state (or province to province). Blaze King Assurance Plan: Included with each gas stove manufactured by Blaze King is a Warranty Card, which must be completed in its entirety and returned to Blaze king within ten days from the date of purchase.
  • Page 8: Copy Of Approval Label

    Do not route power cord beneath heater. Manufactured By: Manufactured Date: 2005 2006 2007 2008 • • • • Blaze King Industries Valley Comfort Systems Inc. APRIL • • • • 146A Street 1290 Commercial Way JUNE JULY • •...
  • Page 9: Electrical Grounding Instructions

    ELECTRICAL GROUNDING INSTRUCTIONS ELECTRICAL GROUNDING INSTRUCTIONS WARNING: The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes with the current edition of National Electrical Code ANSI/NFPA 70, or the current Canadian Electrical Code CSA.C22.1 This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle.
  • Page 10: Planning Your Stove Placement

    CAUTION  The appliance and venting should be inspected before use and annually afterwards by a qualified service person.  More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc.  It is imperative that control compartments, burners, and circulating air passageways of the appliance are kept clean.
  • Page 11: Z 9723 Insert Kit

    Z9723 - 9703 PEGASUS INSERT KIT CONTENTS LOWER LEFT AND RIGHT SHROUD - FIG. 26 MAIN SHROUD - FIG. 27 OUTER TOP - FIG. 28 WIRE SUPPORT BRACKET - FIG. 29 FASTENERS - FIG. 30 TOP TRIM VALVE BRACKET COVER PLATES Date Printed: Thursday, July 05, 2007 Revision Date: March 6, 2006 OM-9703...
  • Page 12 Z9723 - 9703 PEGASUS INSERT KIT ASSEMBLY SCREW AND HOLE IDENTIFICATION - FIG. 32 ATTACH LOWER LEFT AND RIGHT SHROUDS FIG. 33 4 Screws ATTACH LEFT AND RIGHT COVER PLATES– FIG. ATTACH OUTER TOP TO MAIN SHROUD - FIG. 35 POSITION MAIN SHROUD - FIG.
  • Page 13 Z9723 - 9703 PEGASUS INSERT KIT ASSEMBLY INSTRUCTIONS CONTENTS DESCRIPTION PART NUMBER QUANTITY MAIN SHROUD 9781 LEFT LOWER SHROUD R8185 RIGHT LOWER SHROUD R8184 LEFT UPPER SHROUD BRACKET R8186L RIGHT UPPER SHROUD BRACKET R8186R VALVE BRACKET R8144A WIRE SUPPORT BRACKET R8115A TIE WRAP 0810...
  • Page 14 Z9723 - 9703 PEGASUS INSERT KIT ASSEMBLY INSTRUCTIONS 15. Locate the burner switch/piezzo button assembly secured adjacent to the valve. Cut the tie wrap and move the assembly over to the right shroud and line up the two hole two holes on the switch bracket with the holes on the top lip of the right shroud.
  • Page 15: Air Shutter Adjustment

    AIR SHUTTER ADJUSTMENT THERE ARE TWO AIR SHUTTERS THAT REQUIRE ADJUSTMENT. THE SECOND AIR SHUTTER IS OPPOSITE OF THE ONE ILLUSTRATED BELOW. THE SHUTTER SHOULD BE 1/2 WAY OPENED FOR NATURAL GAS AND FULLY OPENED FOR LIQUID PROPANE. THESE SHUTTER SETTINGS ARE APPROXIMATE, THEREFORE THE UNIT SHOULD BE ALLOWED TO BURN FOR ABOUT 10 MINUTES TO SEE IF ANY FURTHER ADJUSTMENTS ARE TO BE MADE.
  • Page 16: Gas Connections

    GAS CONNECTION The gas line may be installed at this time. Make sure to follow all provincial and local codes. Blaze King recommends that gas connections be made by a Licensed and qualified installer. The appliance can be connected to the supply line with either rigid or approved flexible gas connection. Check with provincial and local codes.
  • Page 17: Flue Venting

    9703 - FLUE VENTING WARNING Always refer to current local, state or provincial codes and vent manufacturing specifications for a safe and efficient installation. Caution: Each of the vent manufacturers have their own method of connection. DO NOT MIX B-VENT FROM VARIOUS MANUFACTURERS.
  • Page 18: Burner Conversion Instructions

    BURNER CONVERSION - ROBERT SHAW VALVE LP OR NATURAL GAS CONVERSION KIT SHOULD INCLUDE REGULATOR, MAIN BURNER ORIFICE (x2), AND PILOT ORIFICE. CAUTION: Before proceeding with the conversion the gas supply must be shut off prior to disconnection the electrical power. 1.
  • Page 19: Pilot Conversion

    PILOT CONVERSION -ROBERT SHAW PILOT USE ONLY CONVERSION KITS LISTED BELOW (Model 9703) BLAZE KING PART#’s: NATURAL GAS- Z0750 (0-2000ft. #48/33 main orifices) & Z0750/H (2,000-4500ft.# 49/33 main orifices) PROPANE GAS- Z0748P (0-2000ft/#62/52 main orifices) & Z0748P/H (2,000-4500ft.#63/52 main orifices) TOP VIEW OF BURNER Thermopile Pilot...
  • Page 20: Wiring Diagrams

    WIRING DIAGRAM CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION Snap 15” 15” Disc AC Plug RHEOSTAT Black 23” White Green 23” Thermostat Spark Electrode 12” Stove On/Off 12” Switch TH/TP 30”...
  • Page 21: Lighting Instructions

    LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the previous page. 2. Controls are accessed by opening the right side door panel. 3. Set the optional wall thermostat to lowest setting or switch the Stove On/Off Switch to the off position. 4.
  • Page 22: Parts List

    9703 - REPLACEMENT PARTS LIST PART NAME: PART # INSERT 1. Robertshaw Gas Valve 0718A Honeywell Gas Valve 0720 2. Fan 0719B 3. Main Burner Switch 0725A 4/5/6. Log Set (3 piece) 0813 7. Piezzo Push Button Igniter 0737 8. Shroud Trim Long (Insert only) 0758B “...