Tray Paper Feed/Transport Section - Sharp AL-1000 Service Manual

Digital copier
Hide thumbs Also See for AL-1000:
Table of Contents

Advertisement

(6) Remove the C-ring and the fusing bearing, and remove the
heat roller.
1)
2)
3)
(7) Remove the parts from the heat roller.
Note: Apply grease to the sections specified with
(8) Remove two screws and remove the thermo unit.
3)
C. Assembly procedure
For assembly, reverse the disassembly procedure.
Heat roller
.
3)
2)
1)
1)
2)
8-7

5. Tray paper feed/transport section

A. List
No.
Part name Ref.
1
PPD1 sensor PWB
2
LSU unit
3
Intermediate frame unit
4
Paper feed roller
B. Disassembly procedure
(1) Remove six connectors and screws of the main PWB, and
lift the optical unit and the main PWB to remove.
2)
3)
(2) Remove the PWB insulation mylar and remove the paper
transport detection sensor (PPD2).
2)
1)
AL-1000/1010
page
8-11
8-10
8-10
8-11
2)
2)
2)
1)
1)
3)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-1010

Table of Contents