Venting Methods
The vent system needed for installation is not included.
A 3¹⁄₄" x 10" (8.3 cm x 25 cm) rectangular vent system is
recommended.
Roof Venting
B
A
¹⁄₄
A. 3
" x 10" (8.3 cm x 25 cm)
vent through the roof
B. Roof cap
Calculate Vent System Length
The recommended vent system length is 3¹⁄₄" x 10" (8.3 cm x
25 cm) vent with maximum length of 26 ft (8 m) for vent system.
For the best performance, use no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
Example vent system
3¹⁄₄" x 10" (8.3 cm x 25 cm)
90˚ elbow
3 ft
(0.93 m)
Maximum Length
= 26 ft (8 m)
1 - 90° elbow
= 5 ft (1.5 m)
1 - wall cap
= 0 ft (0 m)
9 ft (2.8 m) straight
= 9 ft (2.8 m)
System length
= 14 ft (4.3 m)
6
Wall Venting
A
B
¹⁄₄
A. 3
" x 10" (8.3 cm x 25 cm)
vent through the wall
B. Wall cap
Wall cap
6 ft (1.8 m)
Recommended Standard Fittings
Vent Piece
90° elbow
Flat elbow
Wall cap
Recirculating Vent Through the Soffit/Cabinet
This vent hood is factory set for venting through the roof or wall.
For recirculating installations, Recirculation Kit Part
Number 883140 is available from the dealer or an authorized
parts distributor. Damper installation is not required.
A
¹⁄₄
A. 3
¹⁄₄
B. 3
C. Vent cover
D. Soffit
C
B
A
A. Hood
B. Vent system
C. Top of cabinet
D. Vent cover
E. Ceiling or soffit
3¹⁄₄" x 10" (8.3 cm x 25 cm)
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
B
C
D
" x 10" (8.3 cm x 25 cm) vent
" x 10" (8.3 cm x 25 cm) elbow
D
E

Advertisement