LifeSOS LS-30 Operation Manual

LifeSOS LS-30 Operation Manual

Ip based wireless home security & control system
Hide thumbs Also See for LS-30:

Advertisement

L
i
f
e
S
O
S
L
i
f
e
S
O
S
THE HOME SECURITY & AUTOMATION SYSTEM
FOR YOUR FUTURE NEEDS
Model LS-30
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS-30 and is the answer not in the manual?

Questions and answers

fadi
March 24, 2025

Is there an illustrative video of the device?

Summary of Contents for LifeSOS LS-30

  • Page 1 THE HOME SECURITY & AUTOMATION SYSTEM FOR YOUR FUTURE NEEDS Model LS-30 OPERATION MANUAL...
  • Page 2 NOTE: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to conjunction with any other antenna or transmitter.
  • Page 3: Table Of Contents

    A-4, Connection Diagram for X-10 Power Line Interface A-5, Terminal Board Connection A-6, Connection Diagram for GSM Module A-7, Using the Same Telephone Line to Connect LS-30, Fax Machine and Telephone Answering Machine A-8, Partial Arm for Group Numbers “91” to “99”...
  • Page 4: Introduction & Installation

    INTRODUCTION & INSTALLATION...
  • Page 5 GUI (Graphic User Interface) HyperSecureLink through the Internet, from all over the world*. The LS-30 is not only a security system but also a home automation controller that allows you to set as many as 16 programmable switches to execute daily commands throughout a whole week.
  • Page 6: Base Unit

    BASE UNIT Front Panel Side Panel Emergency Buttons Speaker To trigger the Emergency help, press both buttons simultaneously. Key Board LCD Display Speaker Volume Control LED status Microphone Rear Panel 3.COM1 5.AUX. Audio 4.COM2 Telephone Line I/P Power adaptor I/P Wire Duct Phone Set Connector 1.ALARM OUT SELECTOR...
  • Page 7: Status Indicators

    STATUS INDICATORS There are three LED indicators in green, yellow and red colors on the front panel. They represent the system operation mode and alarm/ warning status as listed in the following table. State Yellow Green DISARM Flash AWAY HOME DISARM HOME Flash...
  • Page 8: Electrical Installation

    Battery 2 (optional) Battery Switch Battery 1 The LS-30 Base Unit can accommodate 2 rechargeable battery packs. Battery pack 1 is 9.6V/900mA(built-in) and Battery pack 2 (optional) is 9.6V/600mA, providing 6-15 hours back up time. 2. Plug in the power adaptor.
  • Page 9: Mechanical Installation

    MECHANICAL INSTALLATION Placement of the Base Unit It is important for the Base Unit to have a good reception quality for the RF signals transmitted from all the sensors and controllers. Place the Base Unit in the central area at your home or business. Keep the Base Unit away from large appliances and other metal objects.
  • Page 10: User Operation

    USER OPERATION...
  • Page 11 The LS-30 will dial the Latchkey Number (Refer to (4-2-1) Set Telephone Number- Latchkey Number) when these users arm or disarm the system. Duress Code (User 11): Using this code to disarm the system, the LS-30 will dial and send a duress signal to a CMS.
  • Page 12: Initial State

    X-10 switch control (X-10 switch control module is an optional device). Close or open the alarm relay terminals on the rear panel. Open Door (reserved). For AWAY, HOME & DISARM Modes - refer to the OPERATION MODES OF LS-30. The ARM Mode in this manual means AWAY or HOME Mode.
  • Page 13: Telephone Number Check

    (2) System Check Event Check Check By Sequence Check By Date Telephone Number Check (2-1) Voice Check (2-2) Device Check (2-3) Event Check: The Base Unit can store 512 event records in its memory. These events can be checked by time sequence or by entering the date information. Use the keys to move up and down the screen.
  • Page 14 (2-1) Telephone Number Check Common 1 Number Common 2 Number Common 3 Number Common 4 Number Panic Number Burglar Number Fire Number Medical Number Special Number Latchkey Number Pager Number Pager Data Show the telephone numbers stored in the memory and their answering types. (refer to (4-2-1) Set Telephone Number to check the usage of different telephone numbers).
  • Page 15 (2-2) Voice Check All Voice Common Segment Panic Segment Burglar Segment Fire Segment Medical Segment Special Segment Latchkey Disarm Segment Latchkey Away Segment Playback the pre-recorded voice messages. (refer to (4-3) Set Sound to check the usage of different segments of the voice messages). (2-3) Device Check Controller Burglar Sensor...
  • Page 16: Master Mode

    Master Mode Set Bell Door Bell On Device Test Door Bell Off Monitor Mode Set Partial ARM Set Entry Delay (Refer to (4-1) Set Timer- Set Entry Delay.) Set Exit Delay (Refer to (4-1) Set Timer- Set Exit Delay.) Set Clock Time Date Set Switch...
  • Page 17 Exit Delay: Refer to Installer Mode (4-1) Exit Delay. Set Password: Latchkey User: User 9 and User 10 are also called Latchkey Users. The LS-30 will dial the Latchkey Number (Refer to (4-2-1) Set Telephone Number- Latchkey Number) when these users arm or disarm the system.
  • Page 18: Operation Modes Of Ls-30

    OPERATION MODES OF LS-30 The LS-30 can be set into three operation modes to fulfill your requirements in different times and situations. AWAY Mode: When you leave your home or business, set the system into Away Mode. The LS-30 will scan all the sensors that have been set “on duty” and issue an alarm if any sensor detects an abnormal condition after the Exit Delay passes.
  • Page 19: Reaction Of Ls-30 To Different Alarms

    REACTION OF LS-30 TO DIFFERENT ALARMS The response of the LS-30 to various alarms and abnormalities is shown below. Burglar alarms can only be issued when the system is in AWAY or HOME mode, while Fire, Panic and Medical alarms can be triggered anytime, regardless of the system operation mode.
  • Page 20 ANSWERING CALLS FROM THE LS-30 When you receive a call from the LS-30, you can follow the procedures below to communicate with the system. When you pick up the phone, your voice on the line will trigger the appropriate message from the LS-30.
  • Page 21: Dial-In Control

    DIAL-IN CONTROL You can control and check with your LS-30 from a phone anywhere in the world by enabling the auto-answer function (refer to (4-2) Set Telephone – Set Auto Answer) and set the ring count number. Notes: 1. If you connect a fax machine or auto-answering machine on the same telephone line, you might need to refer to their manuals and Appendix A-7 to avoid any disoperation.
  • Page 22: Installer & Cms Settings

    INSTALLER & CMS SETTINGS...
  • Page 23: Installer Mode

    The Installer Mode is for the installer to set up the system. Enter Installer Password (4) Installer Mode Set Timer (4-1) Set Telephone (4-2) Set Sound (4-3) Set Device (4-4) Set Siren (4-5) Set Misc. (4-6) Set GSM (4-7) (4-1) Set Timer Set Entry Delay Set Exit Delay Set Inner Siren Time...
  • Page 24 Sensor Supervise Time: 0-24 Hours (default 4 Hours) The LS-30 is a supervised RF wireless system, meaning all the Burglar sensors send “heartbeat” RF signals to the Base Unit at a certain time interval. If the Base Unit does not receive the RF check signal from a certain sensor within the Sensor Supervise time, the LS-30 will consider this sensor to be missing and issue a warning message.
  • Page 25 (4-2) Set Telephone Set Telephone Number (4-2-1) Set Dial Mode Tone Pulse 33/66 Pulse 40/60 Set Auto Answer Auto Answer On Set Ring Count Auto Answer Off Set Telephone Line Cut Detection Permanent Off Away Mode On Permanent On Set Cease Dialing Mode 30 Minutes Due CMS Report OK Set Tel.
  • Page 26 Permanent OFF) The LS-30 can check the telephone line voltage and if the line is cut, the siren will go off (the Inner Siren should be switched on) to alert the user. (refer to (4-5) Set Siren - Inner Siren.) Permanent OFF: Never check the telephone line state.
  • Page 27: (4-2-1) Set Telephone Number

    5 specific numbers each for different alarms: These will be dialed only when the LS-30 is triggered by the specified alarm. For example, the fire number will be dialed only in a fire alarm. Latchkey number (Power status report number): This number has two purposes: 1).
  • Page 28 PABX extension number. Each pause is equivalent to a 3-second break. Answering status: Voice /Tone (default, Voice). After dialing, the LS-30 needs an acknowledgement from the called party, either by voice like “Hello” or by a DTMF key tone to ensure the call is connected successfully. With no acknowledgement, the call will be deemed to have failed and will be redialed in the next loop.
  • Page 29: Set Sound

    Set Entry Delay Beep Delay Beep On Delay Beep Off Record Voice: After an alarm call connects successfully, the LS-30 will play the prerecorded voice message that corresponds to the alarm type. The messages should be recorded in their specified segments.
  • Page 30 Latchkey Away (4 seconds): The voice to be played when a latchkey user sets the system in AWAY mode. Ex: “I’m out.” Entry Delay Beep: ON/OFF (default, OFF ) Entry Delay Beep ON: The Base Unit will generate beeps during the Entry Delay interval and the beeping speed will get faster until the end of the delay time.
  • Page 31: Set Device

    Select Type (4-4-1) Enable State Enroll Device: The LS-30 uses smart code technology. The Base Unit identifies its sensors by their unique IDs, so the Base Unit has to learn all the sensors’ ID codes in the initial system setup. (Each sensor has a unique ID that is preset at the factory.)
  • Page 32 (4-4-1) Change Device Setting Controller Change Burglar Sensor Change Enter Zone Number Fire Sensor Change Enable State Medical Button Change Zone Number Special Sensor Change Switch Control Enable state of devices: Device On Duty/Bypass (default On Duty): (For all devices) Device On Duty: This sensor is working in the system currently.
  • Page 33: Set Misc

    Siren/Relay OFF: The Relay will not act and sirens will keep silent when there is an alarm issued by this device. Bell ON/OFF (default Bell OFF): (For Burglar sensor) Bell ON: In Disarm Mode, the Base Unit will issue a doorbell chime when receiving a trigger signal from this sensor if the Bell status is set to ON in Master Mode (refer to (3) Master Mode - Bell Check - Door Bell.) Bell OFF: In Disarm Mode, doorbell chime will not sound when receiving a trigger signal...
  • Page 34: Set Siren

    (4-5) Set Siren Set Inner Siren Inner Siren On Inner Siren Off Set Mode Change Chirp Mode Chirp On Mode Chirp Off Set Tamper Siren In Disarm Siren On Siren Off Set Remote Siren Type Standard Series HA Series ID Number Change Siren/Relay Test Start Test Inner Siren: ON/OFF (default ON)
  • Page 35 Tamper Siren In Disarm On: The Siren will go off (if the Inner Siren has been enabled) if some one detaches the Base Unit from the Mounting Bracket or triggers the Tamper Switch (on Base Unit or sensors) in Disarm Mode. Tamper Siren In Disarm Off: The siren will not go off when receiving the tamper signal from sensors or from the Base Unit in Disarm Mode.
  • Page 36: Set Gsm

    (4-7) Set GSM Display RSSI Set GSM Number SMS Number 1(Mobile phone number) SMS Number 2 (Mobile phone number) GSM Number GSM PIN This setting is only valid for the system with a GSM Module and the Tel/GSM Link set as Link=GSM.
  • Page 37: Cms Mode

    Set Password Mode Change Report: ON /OFF (default OFF) Mode Change Report On: The LS-30 will report to the CMS if the operation mode (Away/Home/Disarm) has been changed. Mode Change Report Off: The LS-30 will report to the CMS with only alarm and warning events but no operation mode report.
  • Page 38: Specifications

    SPECIFICATIONS Base Unit Input Power: 12~15V DC, 300mA /400mA. Standby Current: 60-90mA. (depends on the receiver type and rechargeable battery). RF : (Follows local regulations, other frequencies as requested) Frequency: 433 MHz Data Modulation: OOK. Power: less than 10mW. Range: about 200ft or more @open field, 25 . Receiver Type: super heterodyne.
  • Page 39: Appendix

    APPENDIX A-1. Remote Message Display. A user or a CMS can send messages to the LS-30 if the Base Unit has been connected to the Internet through the Ethernet Adaptor (optional) by using the HyperSecureLink program. The LCD display will show “Messages Come In” and issue a warning sound periodically to remind the user if any new message has been received by the LS-30 Base Unit.
  • Page 40: A-5, Terminal Board Connection

    A-5. Terminal Board Connection Wire Arm LED Wire Wire Wire Siren Sensor 3 Indicator Sensor 2 Sensor 1 +12V DC: This terminal provides +12V~15V/200mA output for the customers to connect their own devices. (Note: The output voltage depends on the power adaptor and will be shut down if the external power fails.) ALARM OUT: These two terminals are the Alarm Relay Outputs.
  • Page 41: Remote Controller

    LS-30 ring count> Fax ring count >TAM ring count. Ex. If the ring count of the LS-30 is 8, the ring count of the Fax should be 6 and ring count of TAM should be 4.
  • Page 42 Device List Item Device Type Zone No. Device Location Battery Status (xx-xx) (User Name)

Table of Contents

Save PDF