PLEASE READ THIS MANUAL
BEFORE INSTALLING
AND USING APPLIANCE.
IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation. Fail-
ure to follow these instructions
may result in a possible fire haz-
ard and will void the warranty.
WARNING: If the information in
this manual is not followed ex-
actly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency, or the gas sup-
plier. Do not store or use gasoline
or other flammable vapors and
liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Do not touch electrical
switches.
3. Do not try to light any appli-
ance.
4. Extinguish any open flame.
5. Do not use the phone in your
building.
6. Immediately call your gas
supplier from a neighbor's
phone.
7. Follow your gas supplier's
instructions.
8. If you cannot reach your gas
supplier, call the fire depart-
ment.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided.
Vent-Free
Gas Room Heaters
UVHB20
Homeowner's Installation and
Operating Manual
3501 West Howard • Skokie, IL 60076 • 847-676-3556
INSTALLER: DO NOT DISCARD THIS MANUAL -
Leave in fireplace for homeowner.
www.cfmharris.com
20001540 2/04 Rev. 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVHB20 and is the answer not in the manual?

Questions and answers

Summary of Contents for pyromaster UVHB20

  • Page 1 IMPORTANT: Read all instruc- tions and warnings carefully before starting installation. Fail- ure to follow these instructions UVHB20 may result in a possible fire haz- ard and will void the warranty. WARNING: If the information in this manual is not followed ex-...
  • Page 2: Table Of Contents

    PYROMASTER UVHB20 Vent-Free Heaters ® Table Of Contents General Information ....3 Specifications ..... . 4 Installation .
  • Page 3: General Information

    This appliance may be installed in an aftermarket FOR SAFE INSTALLATION AND OPERATION OF permanently located, manufactured (mobile) YOUR PYROMASTER VENT-FREE ROOM HEATER home, where not prohibited by local codes. PLEASE NOTE THE FOLLOWING: This appliance is only for use with the type of 1.
  • Page 4: Specifications

    FPS1214 Brass Trim (Top) Brass Trim (Side) Hearth Base Mounting 3/4" Tabs UVHB20 Fireplace Hearth Base 1540 Fig. 1 UVHB20 Series specifications. UVHB20 Series Gas Appliance 11³⁄₄" 7" 39⁵⁄₈" 26¹⁄₈" 12¹⁄₂" 26¹⁄₂" 15³⁄₈" 47³⁄₈" FP730 UVHB20 Series specifications and dimensions.
  • Page 5 UVHB20 Vent-Free Heaters ® Description High Elevations The UVHB20 vent-free heater is designed to be in- Input ratings are shown in BTU per hour and are stalled into an FPS1212 or FPS1214 mantel cabinet certified without deration from elevations up to only.
  • Page 6: Installation

    Run Gas Line from Its Preparing the UVHB20 Source to the Heater The UVHB20 may only be used with the approved If gas piping from the source to the heater location has mantel and hearth assembly. not been accomplished, install the required pipe.
  • Page 7 AND THE NATIONAL ELECTRICAL CODE, ANSI/ NFPA NO. 70. 13. Repeat steps 1 through 3 to reassemble the heater. Remote Control (RM2) The UVHB20 is shipped with a remote control that Speed Temperature Control Sensor allows the unit to be turned on or off from anywhere in the room.
  • Page 8 PYROMASTER UVHB20 Vent-Free Heaters ® Log Installation 1. Remove logs from packaging. Top Left Log Top Right Log As with all plastic - these are not toys and should be kept away from children Rear and infants. 2. Place rear log on rear bracket (ensure log is seated...
  • Page 9: Operating Instructions

    PYROMASTER UVHB20 Vent-Free Heaters ® Operating Instructions First Firing Upon completing the gas line connection, a small amount of air will be trapped in the line. When first lighting the unit with pilot light, it will take a few minutes to purge the trapped air.
  • Page 10: For Your Safety Read Before Lighting

    PYROMASTER UVHB20 Vent-Free Heaters ® Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- instructions.
  • Page 11: Troubleshooting

    PYROMASTER UVHB20 Vent-Free Heaters ® Troubleshooting - Honeywell VS8421 START CHECK • Supply line hooked up Gas Supply On • Shutoff valve open • Lockout has engaged. Wait 60 seconds, try again. Pilot Lights with • For spark at electrode while depressing Piezo Ignitor Piezo - 1/8"...
  • Page 12: Maintenance

    PYROMASTER UVHB20 Vent-Free Heaters ® Maintenance Cleaning the Standing Pilot Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing at Control System least twice a year. THE LOGS CAN GET VERY HOT The burner and control system consists of: —...
  • Page 13 8a/b 7a/b 9a/b 1540 CFM Harris Systems reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVHB20 Vent Free Heater Ref. Description UVHB20 Complete Log Set 20001575 Log - Back...
  • Page 14: Replacement Parts

    UVHB20 Vent-Free Heaters ® Accessories The following accessories for these heaters are available from your local Pyromaster distributor. Each accessory comes with a separate installation instruction for mounting to the particular heater. Be sure to read each instruction thoroughly before installing.
  • Page 15 PYROMASTER UVHB20 Vent-Free Heaters ® LIMITED 2/20 YEAR WARRANTY For CFM Harris Systems Decorative Gas Appliances The CFM Harris Systems extends the warranties specified CLUDING IMPLIED WARRANTIES OF MERCHANTABIL- in paragraphs A and B below with respect to its Decorative ITY OR FITNESS FOR A PARTICULAR PURPOSE), ALL Gas Appliances (the “Gas Appliance”), including the CFM...
  • Page 16 PYROMASTER UVHB20 Vent-Free Heaters ® CFM Harris Systems A Division of The Vermont Castings Majestic Products Company 3501 West Howard • Skokie, IL 60076 • 847-676-3556 www.cfmharris.com © CFM Harris Systems 20001540...

Table of Contents

Save PDF