1 = 120V; 2 = 240V fan stages (0 or 1 = 1, 2 = 2) additional product options. Example: 620810 = 6208 Fogmaster Tri-Jet, 120V, 1 stage fan. Compatibility with World Electrical Systems Fogger motors and cord options (KUE-xxx) are available for most electrical supply systems and socket configurations.
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS RELATING TO RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS WARNING – When using electric appliances, follow these basic safety precautions: Read all the instructions before using the appliance. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
Page 4
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug.
SAFETY PRECAUTIONS Do not inhale fog output. Highly atomized liquid droplets can float in the air a long time and are quickly absorbed by the lungs. Depending on the material being fogged, this could result in serious injury or death. Do not use to apply any liquid that is hazardous to people, animals or property when atomized into small droplets.
Product Overview This machine atomizes light liquids into a fog, mist or spray of small droplets. It can atomize both oil- and water-based solutions, as well as emulsions and dilute suspensions of wettable powders. Typical uses of this machine include: •...
Except for the 7807, it is mounted in the power head; Description of Operation Fogmaster foggers atomize liquids into small droplets (fog or mist) by shearing them in a highly turbulent section of the nozzle. A blower in the power head supplies air to create the turbulence.
Equipment Setup The hose and nozzle assembly of the 7807 Noz-L-Jet is shipped in a separate carton, and must be attached to the power head. Attaching the 7807 Noz-L-Jet hose/wand assembly From the open hose end of the hose/wand assembly, gently stretch out the internal tube to access the “push to connect”...
Operation Add chemical solution to the liquid tank. If applying a wettable powder or suspension, remove retaining ring and screen from weighted suction tube. Clamp the power head in place. Using the calibrated flow rate and the dosage instructions provided by the chemical label or chemical manufacturer, calculate the time required to properly fog the area.
Maintenance The major components of the fogger are identified on page 6. A detailed parts list and order form is included as a separate sheet with each unit. This document is also available for download on our web site. WARNING: Unplug fogger power cord from electrical outlet before attempting any maintenance operation.
Page 11
About motor brushes Two graphite brushes convey electric power to the motor commuta- tor. Brushes are a consumable item, and have a lifetime of about 650 operating hours. Operating without the air intake filter lets airborne dirt and moisture enter the motor; this can reduce brush life substantially. When brushes are worn the motor does not operate properly.
Page 12
If the power cord is damaged, it must be replaced with an approved cord that includes continuous line to ground (earth). Return unit to Fogmaster or authorized importing distributor for service. WARNING: A continuous ground (earth) line in the power cord is essential for safe operation. Do not operate machine without a continuous line to earth.
Page 13
Disassemble tubing connector Certain models use “press to insert” quick connect fittings (tube-to-tube couplings, tube-to-thread adapters or tube-to-bulk- head adapters). To make the connection, push the stem into the receptacle and seat firmly. To assemble fitting, push together firmly. Tube Barb Coupling There are two styles of connector.
POWER HEAD HOUSING GROUND RIVET GREEN GROUND RIVET EMI FILTER (CE models) BLACK BLACK WHITE WHITE CORD/PLUG 120V~ MODELS 120V~ MODELS WITH EARTH STANDARD UNIT CE VERSION 100-120VAC 50/60 Hz POWER HEAD HOUSING GREEN GROUND GROUND RIVET RIVET EMI FILTER (CE models) BROWN BROWN...
Specifications Nozzle Technology Counter-rotating vortex design. High turbulence in nozzle shears feed liquid into fog-sized droplets (7-30 microns VMD). Nozzle has no small orifices and is resistant to plugging. Chemicals Nozzle can atomize both oil-based and water-based liquids. Particle size distribution varies with liquid viscosity, surface tension, density and flow rate.
Page 16
Blower Balanced fan, one stage, 20,000 rpm (no load) Two stage fan optional (standard in 7807) Intake Filter Bag type, fits over rear housing. Washable. Materials (b) Power head, wand, tank - aluminum Tank gasket - Buna N Hose - vinyl Tubing - fuel and oil resistant vinyl Fittings - brass;...
This product is warranted for five years [one year for 7807] from the purchase date against defects in materials and workmanship. If you have a warranty claim, return the unit freight prepaid to The Fogmaster Corporation. We will repair or replace (at our option) any defective parts and return the unit to you.
Page 18
In the interest of improving internal design, operational function, and/or reliability, The Fogmaster Corporation reserves the right to make changes to the products described in this document without notice. The Fogmaster Corporation does not assume any liability that may occur due to the use or application of the product(s) described herein.