HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RH203 THROUGH RH224...
Page 2
HEATLESS DRYER SERIES INSTRUCTION AND MAINTENANCE MANUAL IMPORTANT BEFORE INSTALLING OR OPERATING THE DRYER IT IS RECOMMENDED THAT THIS MANUAL BE STUDIED AND CLEARLY UNDERSTOOD. SECTION TOPIC DESCRIPTION SAFETY PRECAUTIONS INSTALLATION OPERATION MAINTENANCE & SYSTEM CHECK PREVENTIVE MAINTENANCE TROUBLESHOOTING GUIDE PARTS LIST PURGE CHART ELECTRICAL SCHEMATIC...
1. SAFETY PRECAUTIONS Warnings, Cautions, and Notes used in this manual have the following significance: WARNING MAINTENANCE OR OPERATING PROCEDURES AND TECHNIQUES THAT WILL RESULT IN PERSONAL INJURY OR LOSS OF LIFE IF NOT CAREFULLY FOLLOWED. CAUTION MAINTENANCE OR OPERATING PROCEDURES AND TECHNIQUES THAT WILL RESULT IN DAMAGE TO EQUIPMENT IF NOT CAREFULLY FOLLOWED.
2. INSTALLATION Arrow Regenerative Air Dryers are shipped as completely assembly packages, filled with desiccant ready to install. Visually check the dryer to make certain that all air lines and electrical connections are securely fastened and were not damaged in transit. If there is evidence of damage, immediately enter a claim with the carrier, and notify your Arrow representative.
Page 5
3. Generally, locate your dryer downstream from the air receiver. The only exception would be on applications with a fluctuating demand. Then the dryer should be located upstream of the receiver to avoid air surges through the dryer’s desiccant beds. 4.
3. OPERATION START-UP After all piping and electrical connections are made, proceed as follows: 1. SLOWLY pressurize the dryer. When the dryer reaches full operating pressure, check the system for air leaks. Soap test all joints and fittings. To maintain desired dewpoint, any leaks detected must be fixed, especially those on the outlet side of the dryer.
Repressurization takes place in a downward direction through the bed, minimizing desiccant dusting. TIMER OPERATION The dryer’s control circuit board or mechanical timer controls the complete cycle. No field adjustment of any kind is required for proper operation. D. ADJUSTABLE PURGE FLOW SYSTEM RH-Series Exhaust Purge Dryers feature an adjustable purge flow system.
Page 8
CAUTION TO MAINTAIN THE PROPER OUTLET DEWPOINT, THE DRYER MUST RECEIVE THE PROPER AMOUNT OF PURGE AIR. IF THERE IS EXCESSIVE BACK PRESSURE IN THE TOWER BEING REGENERATED, CHECK THE PURGE MUFFLER AND PURGE PIPING. BACK PRESSURE IS INDICATED WHEN OFF-LINE TOWER PRESSURE GAUGE READS HIGHER THAT 5 PSIG. THE PIPING AND PURGE MUFFLER MUST BE KEPT CLEAN TO MAINTAIN THE PROPER PURGE RATE.
Page 9
MOISTURE INDICATOR OPERATION Moisture Indicator is provided to warn operating personnel of dryer malfunction. If dryer is functioning properly, desiccant in Moisture Indicator will be blue. Should blue color fade or turn pink, discontinue dryer use and consult Troubleshooting Guide. OPTIONAL EQUIPMENT (IF APPLICABLE) 1.
Page 10
5. Allowing the dryer to operate for two complete cycles ensures that the probe will not be exposed to high humidity and damaging liquid water. This is especially important when dryer has been stored or sitting idle for several months. 6.
4. MAINTENANCE AND SYSTEM CHECK PREFILTERS AND AFTERFILTERS 1. Prefilters - The cartridges of the prefilters must be changed as often as required to prevent contamination of the regenerative dryer’s desiccant bed. The prefilter MUST BE DRAINED DAILY. To prolong filter cartridge life, it is recom mended that a mechanical air/moisture separator be placed immediately before the prefilter.
EXHAUST MUFFLER THE EXHAUST MUFFLER MUST BE PERIODICALLY CHECKED FOR ANY RESTRICTIVE DEBRIS. At high pressures, a clogged muffler could result in high backpressure and could result in mechanical failure or personal injury. EXHAUST MUFFLER CHANGEOUT PROCEDURE WARNING TO AVOID INJURY, DEPRESSURIZE DRYER BEFORE PERFORMING ANY SERVICE.
5. PREVENTATIVE MAINTENANCE DAILY 1. Check and record inlet pressure, temperature and flow. Verify that it is within specifications. 2. Check tower pressure gauge readings within operating tolerance. 3. Check tower pressure gauges for proper dryer cycling 4. Check that there is no condense discharged from prefilters. 5.
6. TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE CORRECTIVE ACTION Elevated Insufficient purge rate 1. Check purge flow settings. Dewpoint 2. Check purge piping for obstruction. 3. Clean purge piping and muffler. Inlet air/gas pressure below 1. Check pressure source. design condition Flow rate higher than design 1.
Page 15
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION Dryer fails to Faulty purge valve 1. Check purge valve and its solenoid pressurize valve. Refer to earlier steps if no pilot air is detected. 2. Check timer sequencing. Dryer Purge valve does not close; dryer 1.
Page 19
120/1/60 G R D S T A R T / S T O P S W I T C H F U S E IL-RT I N D I C A T O R L I G H T - R I G H T T A N K I L - L T I N D I C A T O R T A N K - L E F T T A N K T - P C B...
Page 21
L E F T T O W E R P R E S S U R E P U R G E P R E S S U R E R I G H T T O W E R P R E S S U R E L E F T L E F T R I G H T...