Page 4
www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. AK9228AS / AK9234AS - 480W, 3.9 Amps A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.
MODELS: AK9228AS AND AK9234AS PARTS SUPPLIED 1 - Insert hood body 2 - Baffl e fi lters (3 for AK9234AS) 2 - Halogen light bulbs (pre-installed) 1 - Internal blower (pre-installed) 1 - 8” round adaptor w/damper 1 - 3 1/4” x 10” rectangular adaptor w/damper...
Page 7
Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
Page 8
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fi...
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options side wall cap w/ gravity damper...
ELECTRICAL WARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Page 12
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the insert. If possible, power up and test all functions prior to installation. 1. Remove all packing materials and protective fi lm prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel.
2. Remove grease tray by: 1) Pulling up on tray to 1. Remove baffl e fi lters by: 1) Pulling fi lter toward release from bottom panel. 2) Lifting tray out of front of insert. 2) Pivoting rear of fi lter down. insert body.
Page 14
www.zephyronline.com 2. Remove grease tray by: 1) Pulling up on tray to 1. Remove baffl e fi lters by: 1) Pulling fi lter toward release from bottom panel. 2) Lifting tray out of front of insert. 2) Pivoting rear of fi lter down. insert body.
Page 15
Rect. ducting Round ducting 8. Remove knock-outs A and B for rectangular 7. Using a fl at head screwdriver, remove 8” round ducting. Remove knock outs B and C for round or 3 1/4”x10” rect. knock-out plates at the back ducting.
www.zephyronline.com 10. (Rectangular Ducting) From inside the insert, 10. (Round Ducting) From inside the insert, push push 3-1/4” x 10” rectangular adaptor through 8” round adaptor through the back knock-out the back knock-out and secure to interior back and secure to interior back wall of insert with wall of insert with (8) M4 x 6mm screws.
Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. 2.
Page 18
www.zephyronline.com Baffle Filter Clean Reminder Aa set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 4. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
Page 20
Replacing the Baffl e Filters: Hood Model: Part No. Qty. to Order FIG. 6 AK9228AS / AK9234AS 50210013 (large) AK9234AS 50210017 (small) Cleaning the Grease Tray The grease tray is intended to catch residue and grease that may drip from the baffl e fi lters. The grease tray should be cleaned when baffl...
Page 21
If bulbs are diffi cult to turn due to prolonged use, fi rmly attach the glass suction cup provided to the bulb or use a rubber/latex glove and turn counter clockwise. Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. For Zephyr part numbers please turn to page 22 of the manual. Bottom View...
www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR MONSOON I Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
Page 24
DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 AK9228AS / AK9234AS Baffl e Filter, Large (each) 50210013 AK9234AS Baffl e Filter, Small (each) 50210017 RF Remote Control 14000005 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Page 25
Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.
Need help?
Do you have a question about the AK9234AS and is the answer not in the manual?