DO NOT OPERATE THE GENERATOR BEFORE READING THIS MANUAL AND
ENGINE MANUFACTURER'S OWNER'S MANUAL AND WARNINGS.
THIS STEPHILL GENERATOR HAS BEEN DESIGNED TO PROVIDE SAFE AND EFFICIENT
SERVICE IF OPERATED AND MAINTAINED CORRECTLY.
MANY ACCIDENTS OCCUR THROUGH FAILURE TO ADHERE TO FUNDAMENTAL SAFETY
PROCEDURES.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE6000D and is the answer not in the manual?

Questions and answers

Summary of Contents for Stephill SE6000D

  • Page 1 DO NOT OPERATE THE GENERATOR BEFORE READING THIS MANUAL AND ENGINE MANUFACTURER’S OWNER’S MANUAL AND WARNINGS. THIS STEPHILL GENERATOR HAS BEEN DESIGNED TO PROVIDE SAFE AND EFFICIENT SERVICE IF OPERATED AND MAINTAINED CORRECTLY. MANY ACCIDENTS OCCUR THROUGH FAILURE TO ADHERE TO FUNDAMENTAL SAFETY...
  • Page 2: Table Of Contents

    Control panel Long term storage SERVICE AND MAINTENANCE Engine service Alternator service NAC Alternator spares Yanmar consumable spares SE6000D Spares WARRANTY APPENDICES SE6000D Dual voltage wiring diagram SE6000D L100 Engine wiring diagram SE6000D Base exploded view SE6000D Roof exploded view...
  • Page 3: Specification

    Specification SE6000D dBA@7M Engine Yanmar L100 Alternator NAC 5500 Voltage 230v Neutral bonded to earth & 115v CTE Weight 160Kg Length 1220mm Width 710mm Height 910mm Fuel Hours run 100% load Hours run 75% load 2 General Safety 2.1 Warning Signs Warnings shown on the machine should be observed at all times.
  • Page 4: Potential Hazards

    Operation of the machine in a saline environment will require additional corrosion protection. 4 Safety Considerations 4.1 General All Stephill Generators comply with all the current EEC directives including, the the noise emission in the environment by equipment for use outdoors regulation 2001 (SI 2001/1701).
  • Page 5: Fuel

    Engine/Alternator only. 4.5 Earth Connection All Stephill products are fitted with an earth stud on the control panel this must be connected to an earthing system or spike. Any earth spike required is dependant on the local conditions of use. The size is determined by reference to current IEE regulations or to a competent electrician.
  • Page 6: Fire

    To stop turn key to stop position. 5.4 Fuel System Bleeding Procedure Before attempting to bleed the fuel system on the SE6000D, ensure the key switch is in the off position, the tank has a minimum of 10 litres of fuel and the lid is open.
  • Page 7: Control Panel

    Turn the starter key to the on position, (do not start the generator). The battery and low oil pressure warning lamps should be illuminated. Then slowly turn the starter key to the spring position until the battery warning lamp goes out. You should also hear the fuel solenoid click to indicate it is open.
  • Page 8: Long Term Storage

    5.6 Long Term Storage For storage or long periods of inactivity, Stephill Generators recommend the following: Generators should be stored with oil filled to the correct capacity; Storage periods of 18 months and over may require special lubricants and treatments. If so please seek further advice from the engine manufacturer.
  • Page 9: Se6000D Spares

    – storage, incorrect starting / warm-up / run-in or shutdown. No warranty claim will be considered by STEPHILL unless any defective parts are available for inspection by us, or our nominees, to determine the reason or cause of failure, and STEPHILL is given the option of repair or replacement.
  • Page 14 Stephill Generators Ltd. Wallis Close, Park Farm South, Wellingborough, Northants NN8 6AG Tel: +44 (0)1933 677911 Fax: +44 (0)1933 677916 E-mail: info@stephill-generators.co.uk www.stephill-generators.co.uk...