SPLIT-TYPE AIR CONDITIONERS

OPERATING INSTRUCTIONS

INDOOR UNIT
MSC-A07YV
MSC-A09YV
MSC-A12YV
OPERATING INSTRUCTIONS
To use this unit correctly and safely, be sure to read this operating instructions
before use.
Bedienungsanleitung
Um diese Einheit richtig und sicher zu verwenden, unbedingt diese Bedienungs-
anleitung vor der Inbetriebnahme durchlesen.
NOTICE D'UTILISATION
Pour avoir la certitude d'utiliser cet appareil correctement et en toute sécurité, veuillez
lire attentivement cette notice d'instructions avant de mettre l'appareil en fonction.
GEBRUIKSAANWIJZING
Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze
gebruiksaanwijzing aandachtig door te lezen.
MANUAL DE INSTRUCCIONES
Para emplear correctamente este aparato y por razones de seguridad debe leer
este manual de instrucciones de manejo antes de su utilización.
LIBRETTO D'ISTRUZIONI
Per utilizzare correttamente quest'unità, leggere questo libretto d'istruzioni atten-
tamente e per intero.
√¢∏°π∂™ §∂π∆√Àƒ°π∞™
°È· Ó· ¯ÚËÛÈÌÔÔÈ‹ÛÂÙ ·˘Ù‹ ÙËÓ ÌÔÓ¿‰· ÛˆÛÙ¿ Î·È Ì ·ÛÊ¿ÏÂÈ·, ‚‚·Èˆı›ÙÂ
fiÙÈ ¤¯ÂÙ ‰È·‚¿ÛÂÈ ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ Ô‰ËÁÈÒÓ ÚÈÓ ·fi ÙËÓ ¯Ú‹ÛË.
INSTRUÇÕES DE OPERAÇÃO
Para utilizar esta unidade correctamente, certifique-se de que lê estas instruções
de operação antes da utilização.
BRUGSANVISNING
Læs denne brugsanvisning før brugen så korrekt og forsvarlig anvendelse af klima-
anlægget sikres.
BRUKSANVISNING
För att använda enheten på rätt och säkert sätt ska denna bruksanvisning läsas
innan enheten tas i bruk.
‹fiLETME TAL‹MATLARI
Bu birimi do¤ru ve güvenli olarak çal›flt›rmak için, kullanmadan önce bu iflletme
talimatlar›n› mutlaka okuyun.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования прибора следует
до начала его эксплуатации внимательно прочитать данное руководство.
For customers
English
Für Kunden
Deutsch
A l'attention des clients
Français
Voor de klant
Nederlands
Para los clientes
Español
Per gli utenti
Italiano
°È· ÙÔÓ ÂÏ¿ÙË
∂ÏÏËÓÈο
Para os clientes
Português
Til kunden
För kunder
Svenska
Sat›n al›c›lar için
Türkçe
Для пользователей
Русский
Dansk

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSC-A07YV

  • Page 1: Operating Instructions

    Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire attentivement cette notice d’instructions avant de mettre l’appareil en fonction. INDOOR UNIT GEBRUIKSAANWIJZING Voor de klant MSC-A07YV Nederlands • Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze MSC-A09YV gebruiksaanwijzing aandachtig door te lezen.
  • Page 2: Table Of Contents

    CONTENTS • SAFETY PRECAUTIONS ................................ 2 This air conditioner is NOT intended for use by children or infirm persons without supervisions. NAME OF EACH PART ................................3 WARNING PREPARATION BEFORE OPERATION ..........................4 I FEEL... AUTO OPERATION ..............................6 Do not use intermediate connection of the power supply cord or the extension cord and do not MANUAL OPERATION (COOL, DRY, HEAT/FAN) ........................
  • Page 3: Name Of Each Part

    SAFETY PRECAUTIONS NAME OF EACH PART Indoor unit CAUTION When the unit is to be cleaned, switch it off and disconnect the power supply plug or turn off the Front panel breaker. Air cleaning filter • Since the fan rotates at high speed during operation, this may cause an injury. (White bellows type) Air inlet When the unit is not going to be used for a long time, disconnect the power supply plug or turn off...
  • Page 4: Preparation Before Operation

    NAME OF EACH PART PREPARATION BEFORE OPERATION Remote controller Auto restart function These models are equipped with an auto restart function. If you do not want to use this function, Signal transmitting section please consult the service representative because the setting of the unit needs to be changed. Auto restart function is ...
  • Page 5: Emergency Operation

    PREPARATION BEFORE OPERATION Handling of the remote controller Remote controller When the remote controller cannot be used (emergency operation) • The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in- When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation How to set the batteries and the current door unit.
  • Page 6: I Feel

    I FEEL... AUTO OPERATION With the “ (I FEEL...)” auto operation mode, the optimum room condition can be set automatically Description of “I FEEL...” mode with a one-touch operation. Details of operation To start operation: According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or ON/OFF Press the button.
  • Page 7: Manual Operation (Cool, Dry, Heat/Fan)

    MANUAL OPERATION (COOL, DRY, HEAT/FAN) AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT AIR FLOW velocity and direction can be selected as required. To select the COOL, DRY or HEAT/FAN mode: To change the AIR FLOW velocity, press the button. ON/OFF Press the button.
  • Page 8: Econo Cool Operation

    ECONO COOL OPERATION WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Use this operation when you want to be comfortable in COOL mode even with energy saved. Perform the following operations while the unit is operat- When it is not going to be used for a long When the air conditioner is to be used ing in the MANUAL COOL mode.
  • Page 9: Cleaning The Catechin Air Filter

    CLEANING THE CATECHIN AIR FILTER REPLACEMENT OF THE AIR CLEANING FILTER When the capacity is lowered because of dirt, etc., it is necessary to replace the air cleaning filter. Cleaning the catechin air filter (about once every 2 weeks) Air cleaning filter replacement (about once every 4 months) Remove the catechin air filter.
  • Page 10: Before Contacting The Service Representative, Check The Following Again

    BEFORE CONTACTING THE SERVICE REPRE- WHEN YOU THINK THAT TROUBLE HAS OCCURRED SENTATIVE, CHECK THE FOLLOWING AGAIN Question Answer (not a malfunction) Question Answer (not a malfunction) The air conditioner cannot • This protects the air conditioner according to in- The air flow direction •...
  • Page 11: Installation, Relocation And Inspection

    Consult your dealer. If you have any questions, consult your dealer. SPECIFICATIONS NOTE: Set name MSH-A07YV MSH-A09YV MSH-A12YV MS-A07YV MS-A09YV MS-A12YV 1. Rating condition Model Indoor MSC-A07YV MSC-A09YV MSC-A12YV MSC-A07YV MSC-A09YV MSC-A12YV Outdoor MUH-A07YV MUH-A09YV MUH-A12YV MU-A07YV MU-A09YV MU-A12YV Cooling —...
  • Page 12 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on • Low Voltage Directive 73/23/ EEC the following EU regulations: • Electromagnetic Compatibility Directive 89/336/ EEC HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN SG79Y267H01...