Commands for setting of the GAMMA user data
Function
RED GAMMA DATA TRANSFER
GREEN GAMMA DATA TRANSFER
BLUE GAMMA DATA TRANSFER
RED GAMMA DATA READ
GREEN GAMMA DATA READ
BLUE GAMMA DATA READ
USER DATA INITIALIZE
USER DATA SAVE
To transfer the GAMMA user data
Use the user data transfer commands (UGRW, UGGW and UGBW). For each of the R, G and B colors, divide the total 512
pieces of user data into 16 blocks, and transfer 32 pieces of data with each command.
* If data is less than 4 digits, add a "0" (zero) to make it 4 digits.
* The checksum field is the character string (ASCII) data of lower-order one byte which indicates the sum of the block number
and 32 pieces of data in hexadecimal (0 to F).
Saving the GAMMA user data
Use the user data save command (UGSV) to save the transferred user data in the monitor.
If the data is not saved, it will be cleared when:
• The main power switch is off
• STANDBY MODE is LOW POWER and the monitor enters standby mode
Activating the GAMMA user data
To activate the transferred user data, select USER for GAMMA in the PICTURE menu, or send the corresponding control
command.
Checking the GAMMA user data
Use the user data read commands (UGRR, UGGR and UGBR) to return 512 pieces of user data for each of the R, G and B
colors. Divide the data into 16 blocks and return 32 pieces of data with each command. The value to be returned is not the value
stored in the monitor, but the value in the temporary memory for display. (These values are the same when the user data save
command (UGSV) above has been sent.)
TIPS
• The user data is not initialized by RESET of the PICTURE menu. To initialize the user data, use ALL RESET of the
FUNCTION menu.
The GAMMA user data initialize command (UGRS) allows the initialization of the user data only.
Command
Direction
Parameter
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
UGGW
W
aa: 01-16
UGBW
W
xxxx: 0000-1023
cc: 00-FF
UGRR
W
1-16 xxxx ··· xxxx
UGGR
W
1-16
UGBR
W
1-16
UGRS
W
0
UGSV
W
0
C1
C2
C3
C4
Command field Block number (01 to 16) Data field
Example: To transfer the data of block 1 (0 to 31 levels)
of red (R) data
UGRW 01000000010002 ... 0031C0
One piece of data consists
Command Block number
Controlling the Monitor with a PC (LAN)
Reply
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
Initialize the user data.
Save the user data in the monitor.
...
P1
P2
P3
P4
Checksum field
of 4 digits.
32 pieces of data
Checksum
Control/Response contents
S1