Condenser **** won't stay on but a couple seconds
1 comments:
Mr. Anderson
February 11, 2025
The condenser on the Manitowoc Indigo Series may not stay on for more than a couple of seconds due to several possible issues:
1. Fan Cycling Control – If a fan cycling control is used instead of a head pressure control valve, the condenser may not function correctly. The manual states that fan cycling controls should not be used as they can lead to compressor failure.
2. Improper Installation – Issues such as restricted airflow, dirty condenser fins, or high inlet air temperature can cause the condenser to shut down quickly.
3. Electrical Issues – Problems with the condenser fan motor circuit, such as exceeding the rated amps listed on the ice machine’s serial tag, could prevent continuous operation.
4. Refrigeration System Problems – An improper refrigerant charge or a defective head pressure control valve may cause the condenser to shut off prematurely.
5. Condenser Discharge Air Recirculation – If warm air from the condenser is recirculated back into the system, it can cause overheating and shutdown.
Checking these factors can help identify and resolve the issue.
This answer is automatically generated
John M Samaha
February 7, 2025
Need to know when IY1404A-261 SN: 1101224994 was built
avaibility?
March 21, 2025
avaibility and cost?
1 comments:
Mr. Anderson
March 21, 2025
There are no featured offers available for the Manitowoc Indigo Series parts, meaning no offers currently meet the platform's quality, price, delivery, and customer service standards. To check availability and pricing, select "See All Buying Options" on the product page.
This answer is automatically generated
Alex Nissley
April 26, 2025
Hello, I'm trying to install a new motherboard but I keep getting "invalid model" message
Need help?
Do you have a question about the Indigo Series and is the answer not in the manual?
Questions and answers
Condenser **** won't stay on but a couple seconds
The condenser on the Manitowoc Indigo Series may not stay on for more than a couple of seconds due to several possible issues:
1. Fan Cycling Control – If a fan cycling control is used instead of a head pressure control valve, the condenser may not function correctly. The manual states that fan cycling controls should not be used as they can lead to compressor failure.
2. Improper Installation – Issues such as restricted airflow, dirty condenser fins, or high inlet air temperature can cause the condenser to shut down quickly.
3. Electrical Issues – Problems with the condenser fan motor circuit, such as exceeding the rated amps listed on the ice machine’s serial tag, could prevent continuous operation.
4. Refrigeration System Problems – An improper refrigerant charge or a defective head pressure control valve may cause the condenser to shut off prematurely.
5. Condenser Discharge Air Recirculation – If warm air from the condenser is recirculated back into the system, it can cause overheating and shutdown.
Checking these factors can help identify and resolve the issue.
This answer is automatically generated