6.10 Jump frequency - jumping resonant frequencies
• Function
Resonance due to the natural frequency of the mechanical system can be avoided by jumping the
resonant frequency during operation. During jumping, hysteresis characteristics with respect to the jump
frequency are given to the motor.
6
[Parameter setting]
Title
Do not set the jump parameters, if multiple jump frequency setting width overlap.
During acceleration or deceleration, the jumping function is disabled for the operation frequency.
: Jump frequency 1
: Jumping width 1
: Jump frequency 2
: Jumping width 2
: Jump frequency 3
: Jumping width 3
Output command frequency
(Hz)
Jump frequency 3 (
)
Jump frequency 2 (
)
Jump frequency 1 (
)
0
Function
Jump frequency 1
Jumping width 1
Jump frequency 2
Jumping width 2
Jump frequency 3
Jumping width 3
Jumping width 3 (
Jumping width 2 (
Jumping width 1 (
Frequency setting signal
Adjustment range
0.0-
(Hz)
0.0-30.0 (Hz)
0.0-
(Hz)
0.0-30.0 (Hz)
0.0-
(Hz)
0.0-30.0 (Hz)
F-30
E6581158
)
)
)
Default setting
0.0
0.0
0.0
0.0
0.0
0.0