Display Annunciators Adrs Power supply is addressed to listen or talk over a remote interface. Power supply is in remote interface mode. Displays the output voltage and current for +6V supply. Knob is active for +6V supply. +25V Displays the output voltage and current for +25V supply. Knob is active for +25V supply.
The Rear Panel at a Glance 1 Power-line voltage setting 4 Power-line module 2 Power-line fuse-holder assembly 5 GPIB (IEEE-488) interface connector 3 AC inlet 6 RS-232 interface connector Use the front-panel key to: I/O Config • Select the GPIB or RS-232 interface (see chapter 3). •...
Chapter 1 Specifications Supplemental Characteristics Supplemental Characteristics Output Programming Range (maximum programmable values) +6V Output +25V Output -25V Output Voltage 0 to 6.18 V 0 to 25.75 V 0 to -25.75 V Current 0 to 5.15 A 0 to 1.03 A 0 to 1.03 A ±...
Page 19
Supplemental Characteristics ° ° *See the next page for detailed information.
Page 20
Supplemental Characteristics Figure 1-1. Dimensions of Agilent E3631A Power Supply...
Any Agilent Technologies System II instrument of the same size can be rack-mounted beside the Agilent E3631A power supply. To rack mount the power supply, follow these procedures. Remove the front and rear bumpers before rack-mounting the power supply.
Page 38
Chapter 2 Quick Start To rack mount the power supply To rack mount two instruments of the same depth side-by-side, order lock-link kit 5061-9694 and flange kit 5063-9214. To install two instruments in a sliding support shelf, order suport shelf 5063- 9256, and slide kit 1494-0015.
For further details on programming the power supply, see chapters 3 and 4 in the Agilent E3631A User's Guide. Recommended Test Equipment The test equipment recommended for the performance verification and adjustment procedures is listed below.
Chapter 3 Calibration Procedures Measurement Techniques Measurement Techniques Setup for Most Tests Most tests are performed at the front terminals as shown in the following figure. Measure the dc voltage directly at the (+) and (-) terminals on the front panel. Figure 3-1.
GPIB or RS-232 controller. Complete instructions on front panel and remote programming are given in the Agilent E3631A User's Guide. Voltage and Current Values The full-scale and maximum values of each supply are listed below. You can use this table when you test CV and CC performance verification tests.
Chapter 6 Replaceable Parts Manufacturer’s List Manufacturer’s List Mfr Code Manufacturer’s Name Manufacturer’s Address Zip Code 00746 ROHM CO LTD KYOTO, JP 00779 AMP INC HARRISBURG, PA 17111 00830 KYOCERA INTERNATIONAL INC SAN DIEGO, CA 92123 01295 TEXAS INSTRUMENTS INC DALLAS, TX 75265 01870...
Need help?
Do you have a question about the E3631A and is the answer not in the manual?
Questions and answers