Instruction Manual mif 4 Rosendahl mif 4 is a professional midi timecode interface with LED display, sync input and USB port www.rosendahl-studiotechnik.com - 1 -...
The unit is shipped with four small plastic feet mounted underside with Philips screws. If you want to rackmount your mif 4, please detach the four plastic feet first and keep the M3x6mm Philips screws. Now remove the black countersunk screws on the left and right side of the unit to assemble the rack mount brackets using the M3x6mm Philips screws.
2. Powering up and selecting timecode SOURCE Connect the USB port to a host computer or use the external power adapter to supply your mif 4. Each time the unit is powering up the installed firmware version is shown in the display for two seconds.
3. LTC input mode LTC is longitudinal timecode according SMPTE 12M, there are 80 bits containing time, userdata and a syncword. The unit detects the incoming LTC frame format automatically. The FPS LEDs 24, 25, 30 and DF indicate the detected format. 24 FPS timecode is used for movie productions.
Digital Audio Workstations as well as lighting and show control software use MTC midi timecode for synchronisation. mif 4 reads MTC to regenerate synchronised, stable LTC and MTC timecode. MTC timecode can be quite unstable and jittery caused by the latency of computer operating systems.
In MTC or USB input modes the LOCKED threshold is < 5ms, in LTC mode < 100µS. If the incoming midi timecode is jumping or drifting away so that mif 4 is unable to follow the source it will display ERROR 01 in MTC mode or ERROR 02 in USB mode.
Page 8
Example: DAW software sends MMC comands to control the mif 4 timecode generator genlocked to video syncs and then slaves itself to the returned MTC midi timecode generated from the mif 4 to achieve video genlocked playback start (locked to a virtual machine).
6. DISPLAY modes Press the right key to select one of four display modes: TC timecode in hours, minutes, seconds and frames. UB so-called LTC userbits, 8 nibbles shown hex from 0 to F. CAL showing the speed of the timecode output. Display mode CALIBRATION is showing the factor of the current timecode speed used related to nominal speed.
Page 10
In GENERATOR mode the following video syncs are accepted as reference, depending on the selected timecode standard: 24 FPS: 1080p23, 1080p24, 576i47, 576i48 25 FPS: 576i50, 720p50, 1080p25, 1080i50, 1080p50 30 FPS and 30 DF: 720p59, 720p60, 480i29, 480i30, 1080p29, 1080p30, 1080i59, 1080i60, 1080p59, 1080p60 REF displays the automatically detected video reference standard applied on the video sync input:...
7. Firmware update The firmware version installed in your mif 4 is displayed for two seconds every time the unit is powering up. To update the firmware you need a PC running Windows XP or later. Please visit www.rosendahl-studiotechnik.com and download the newest mif 4 firmware utility.
8. Declaration of conformity Rosendahl Studiotechnik GmbH Andechser Str. 5 D-86919 Utting a.A. Germany herewith confirms that the product: Type: professional midi timecode interface Model: mif 4 meets the requirements of the council of the European communities relating to electromagnetic...