DutchWest CDW244 Owner's Manual

High efficiency
Hide thumbs Also See for CDW244:

Advertisement

Available languages

Available languages

High Efficiency Wood Stove
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND
MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN
DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
This manual describes the installation and operation of the Model CDW244 non-catalytic wood heater. This
heater meets US Environmental Protection Agency's emission limits for wood heaters. Under specific condi-
tions this heater has been shown to deliver heat at rates ranging from 10,600 to 26,100 BTU/hr.
This stove is listed by OMNI-Test Laboratories of Port-
land, Oregon to meet UL1482 for the US and ULC-627
for Canada
Do Not Discard This Manual: Retain for Future Use
Model CDW244
Owner's Manual
6" Flue required
30004576 1/09 Rev. 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDW244 and is the answer not in the manual?

Questions and answers

Summary of Contents for DutchWest CDW244

  • Page 1 DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. This manual describes the installation and operation of the Model CDW244 non-catalytic wood heater. This heater meets US Environmental Protection Agency’s emission limits for wood heaters. Under specific condi- tions this heater has been shown to deliver heat at rates ranging from 10,600 to 26,100 BTU/hr.
  • Page 2: Before Installation Of Your Appliance

    CDW244 Today’s solid fuel appliances are much more efficient CAUTION than in the past. The units are designed to give you controlled combustion, as well as maximum heat trans- After reading these instructions, if you have any doubt fer, using less fuel to do so.
  • Page 3: Installation

    CDW244 Installation 2 Full Figure 2 Bricks Brick Placement Baffle Assembly Contact your local bulidng inspector prior to installa- tion. A permit may be required in your area. 1. Remove all parts from inside the stove body. 2. Select the proper location for the stove. These ap- pliances must not be installed any closer than the minimum clearance to combustible materials.
  • Page 4: Floor Protection

    CDW244 space, closet, concealed space, floor, ceiling, wall or Floor Protection any partition of combustible construction. Installation on a Concrete Floor 5. The minimum overall height of your chimney should An appliance mounted on a concrete floor does not be 15 feet (5 m) from the floor. (Fig. 3) require floor protection.
  • Page 5: Building A Fire

    CDW244 It is normal to see flat spots on painted surfaces of the Never use gasoline, gasoline-type latern fuel, ker- stove. The flat spots on the paint surface indicate the osene, charcoal lighter fluid or similar liquids to hotter surfaces of the stove, and is caused by the heat start or ‘freshen up’...
  • Page 6: Ash Disposal

    CDW244 The following steps should be followed for door gasket WARNING: Things to remember in case of chim- replacement: ney fire: 1. Close draft control. 2. Call the fire de- 1. Ensure appliance is not in operation and has thor- partment.
  • Page 7: Environmental Conditions

    CDW244 adding small pieces of seasoned (dry) firewood, 7. Is it normal for soot to cover the glass at the keeping the door slightly open until each piece beginning of a fire? starts to ignite. Remember to always open the Your stove has been built with an air wash system door slowly when placing wood into the fire.
  • Page 8 CDW244 c. Cold Chimney Temperature 10.Should I close or open the air control fully when shutting down the stove? Avoid cold chimney temperatures by burning a hot fire for the first fifteen to forty minutes, being When shutting down the stove, fully open the air careful not to over fire.
  • Page 9 CDW244 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. CDW244 Wood Stove Item No. Description Qty. Part No. Door Assembly 90000082 2 & 3. Glass & Gasket...
  • Page 10: Year Warranty

    5 Year Warranty CDW244 MHSC warrants that your new wood burning stove or masonry • The appliance has any damage due to water, or weather damage that is the result of, but not limited to, improper chim- wood insert is free from manufacturing and material defects for a ney/venting installation.
  • Page 11 CDW244 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com 30004576...
  • Page 12 Lire avec soin les instructions suivantes avant d’installer le poêle Modèle CDW244 non catalytique. Ce poêle respecte les limites d’émission pour les poêles à bois fixées par l’agence Américaine de protection de l’environnement.
  • Page 13: Avant D'installer Votre Appareil

    CDW244 Mise En Garde Fonctionnement Aprés avoir lu ces instructions, si vous avez des doutes Pourquoi un conduit d’évacuation de 6 po (152 quant à votre capacité de faire toute l’installation d’une mm)? manière professionnelle, vous devriez retenir les servic- es d’un installateur qui s’y connaît relativement à...
  • Page 14 CDW244 Si vous ne respectez pas les distances de dégage- TOUJOURS FOURNIR UNE SOURCE D’AIR FRAIS ment minimales requises et ne disposez pas sur DANS LA PIÈCE OÙ L’UNITÉ EST INSTALLÉE. une surface non combustible, votre installatio pour- L’ÉCHEC POUR FAIRE SI PEUT AVOIR POUR rait présenter des problèmes de sécurité.
  • Page 15 CDW244 6. Il est recommandé de limiter à un maximum de 2 Cheminée le nombre de coudes à 90° dans le tuyau à fumée Consultez les instructions du fabricant de la chemi- installé; autrement, vous risquez de réduire le tirage, née et des connecteurs de la cheminée.
  • Page 16: Utilisation Du Poêle

    CDW244 Utilisation du poêle Pendant le mûrissement de la peinture, cette dernière deviendra collante. Une fois qu’elle est mûrie, la N’utilisez pas de grille dans le poêle pour relever le feu. peinture restera dure. Il est normal de voir des en- Établissez votre feu directement sur le fond de la cham-...
  • Page 17 CDW244 9. Quand vous ajoutez du bois, régléz le volet Remplacement d’un joint d’admission d’air en position complètement ou- Aprés un usage intensif, le matériau des joints de la verte. Si le feu devient trop ardent, ouvrez un peu la porte et de la vitre peut devoir être remplacé...
  • Page 18 CDW244 Comment prévenir l’accumulation de créosote IMPORTANT 1. Plusieurs fois par jour durant la saison de chauffage, Conseils qui valent la peine d’être répétés ouvrez le volet d’admission d’air pendant plusieurs 1. Quelle est la bonne manière d’allumer un feu? minutes;...
  • Page 19 CDW244 2. Quel est le meilleur type de bois qu’on peut 8. Qu’entend-on par tirage? utiliser dans le poêle? Le tirage peut être exprimé comme étant la capacité Vous devriez utiliser du bois dur sec. Évitez d’utiliser de la cheminée à évacuer les sous-produits de toule du bois vert.
  • Page 20 CDW244 partie de la cheminée ou du poêle commencent à rougir, votre feu est trop vif. Lorsque c’est pos- sible, installez un thermomètre sur la cheminée de sorte que vous pourrez constater toute chute de la température dans la cheminée.
  • Page 21 MHSC se réserve le droit de faire des changements en ce qui concerne la conception, les matériaux, les spécifications et les prix et de discontinuer des couleurs et des produits à tout moment sans préavis. Poêle à bois CDW244 Description Qtée.
  • Page 22 CDW244 30004576...
  • Page 23 CDW244 Garantie de cinq ans MHSC garantit votre nouveau poêle à bois ou insert en bois et en maçon- 11. Cette garantie est nulle si : nerie contre tout défault de fabrication et de matérial poiur une périods • l’appareil a été mis en marche dans des atmosphères contami- de cinq ans à...
  • Page 24 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

This manual is also suitable for:

Cdw270007Cdw300007

Table of Contents