Solahart Streamline Owner's Manual

Solahart Streamline Owner's Manual

Direct open circuit solar water heater
Hide thumbs Also See for Streamline:
Table of Contents

Advertisement

Streamline
Direct Open Circuit
SOLAR WATER HEATER
OWNER'S MANUAL
AND
Warranty / INSTALLATION INFORMATION
WARNING: Plumber – Be Aware
Use copper pipe ONLY. Plastic pipe MUST NOT be used.
It is a requirement of a solar water heater installation that all pipe work be in copper
and not plastic, due to the effects of high water temperatures and pressures.
Solahart Industries Pty Ltd
ABN 45 064 945 848
This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Streamline and is the answer not in the manual?

Questions and answers

Summary of Contents for Solahart Streamline

  • Page 1 It is a requirement of a solar water heater installation that all pipe work be in copper and not plastic, due to the effects of high water temperatures and pressures. Solahart Industries Pty Ltd ABN 45 064 945 848 This water heater must be installed and serviced by a qualified person.
  • Page 2 TRADE MARKS ® Registered trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. ™ Trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. Note: Every care has been taken to ensure accuracy in preparation of this publication.
  • Page 3: Table Of Contents

    Installation – Solar Control Unit ....................32 Installation – Solar Collectors ....................35 Connections – Plumbing ......................40 Connections – Electrical ......................43 Commissioning .......................... 47 Draining The Solar Collectors ....................50 Draining The Water Heater ....................... 50 Warranty ............................. 53 Solahart Offices ......................... 56...
  • Page 4: About Your Water Heater

    Solahart L, LCS or TBT200 (T) solar collectors. This single element model solar storage tank has only one front cover, located at the midpoint of the tank.
  • Page 5 ABOUT YOUR WATER HEATER Normal operation As the sun heats the water in the solar collectors, the increase in temperature activates the circulator. The circulator switches on whenever the water in the solar collectors is hotter than the water in the solar storage tank.
  • Page 6: About Your Water Heater

    The amount of water heated by the raised booster heating unit of the Streamline solar storage tank is 220 litres (410 model), 170 litres (320 model) or 140 litres (270 model).
  • Page 7 “Booster Control” heating unit. Refer to on page 8. minimum booster setting Solahart recommends the thermostat is set at 60°C to maximise solar contribution. maximum recommended supply temperature to Note: AS 3498 requires that a water heater provides the means to bathrooms and ensuites inhibit the growth of Legionella bacteria in potable water.
  • Page 8 Warning: For continued safety of this water heater it must be installed, operated and maintained in accordance with the Owner‟s Guide and Installation Instructions. The Solahart warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions.
  • Page 9 ABOUT YOUR WATER HEATER Timer Control Switch A timer control switch can be installed and will help maximise energy savings with an electrically boosted solar water heater connected to a continuous, time of use or extended Off-Peak (overnight and day) electricity supply.
  • Page 10 It is essential the electrical circuit to the solar control unit is continually turned on if there is a risk of freezing. The Solahart warranty does not cover damage caused by freeze conditions when the electrical circuit to the solar control unit is turned off or interrupted.
  • Page 11 (10) minutes. This does not indicate a fault. If the red LED continues to emit a rapid pulse for longer than ten (10) minutes, or emits a series of flashes, then count the number of flashes and phone your nearest Solahart Dealer to arrange for an inspection.
  • Page 12 The freeze protection system will be rendered inoperable if electrical power is not available at the solar control unit. Damage caused by freezing due to no power at the solar control unit is not covered by the “Terms of the Solahart Warranty” Solahart warranty. Refer to on page 53.
  • Page 13 ABOUT YOUR WATER HEATER TO TURN ON THE WATER HEATER  Open the cold water isolation valve fully at the inlet to the water heater.  If the solar collectors and solar hot and solar cold pipes have been drained, it will be necessary to bleed “Bleeding the Solar Collectors”...
  • Page 14: Regular Care

    Note: The five year service and routine replacement of any components, such as the anode and relief valves, are not included in the Solahart warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 15 Have any trees trimmed which may shade the solar collectors. Solahart solar collectors have passed the AS/NZS 2712 requirements for resistance to hailstone damage, so it is not normally necessary to fit a guard to a collector. Stone Guards are available to provide a level of protection to the collectors against vandalism or accidental damage.
  • Page 16: Regular Care

    REGULAR CARE FLUSHING THE SOLAR COLLECTORS It may be necessary to flush the solar collectors if there is sediment in the water supply. This should be conducted in the morning, within three hours of sunrise. Warning: It is important flushing of the solar collectors be conducted early in the morning, within three hours of sunrise, when the sun is low in the sky.
  • Page 17: Water Supplies

    Solahart warranty to apply. ANODE The vitreous enamel lined cylinder of the water heater is only covered by the Solahart warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is used.
  • Page 18 Where the saturation index exceeds +0.40, the water is very scaling. An expansion control valve must be fitted on the cold water line after the non-return valve to protect and for the Solahart warranty to apply to the temperature pressure relief valve and water heater cylinder. Solar collectors in a direct solar water heater system should be covered when the water heater is not intended to be used for more than two weeks.
  • Page 19: Water Supplies

    The water heater, solar collectors and their components are not suitable for certain water chemistries. Those chemistries are listed below. If the water heater is connected at any time to a water supply with the following water chemistry, the Solahart warranty will not cover any resultant faults on the components listed below: Water Chemistry Component Total Dissolved Solids (TDS) >...
  • Page 20: Save A Service Call

     Collector area is too small For most installations, the number of solar collectors recommended in Solahart literature has been proven to provide the required solar energy to meet the average family needs. However, in some circumstances, it may be necessary to install an additional solar collector.
  • Page 21 Heavy flows of hot water until the water heater is cold - then stops until water reheats The water heater must be switched off at the isolating switch or switchboard. Phone your nearest Solahart Dealer to arrange for an inspection. EXPANSION CONTROL VALVE RUNNING...
  • Page 22: Save A Service Call

    If the power outlet for the solar control unit is switched on, switch off for a few seconds and then switch on again. If the green LED remains off there may be a fault with the water heater. Phone your nearest Solahart Dealer to arrange for an inspection.
  • Page 23 COLLECTOR GLASS The Solahart warranty DOES NOT cover breakage of solar collector glass. Check your household insurance policy covers collector glass breakage.
  • Page 24: Installation – System

    THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. SOLAR COLLECTORS The system is suitable for installation with Solahart L, LCS or TBT200 (T) solar collectors. In Australia, systems with L solar collectors are suitable for installation in all climate zones.
  • Page 25 “Terms of the Solahart Warranty” available at the solar control unit (refer to on page 53). Note: The Solahart warranty against freeze damage applies only to systems installed in Australia. INSTALLATION STANDARDS The water heater must be installed: ...
  • Page 26 INSTALLATION – SOLAR STORAGE TANK SOLAR WATER HEATER STORAGE TANK LOCATION The solar storage tank is suitable for either outdoor or indoor installation. Whether located outdoor or indoor, the solar storage tank should be installed close to the most frequently used outlet and its position chosen with safety and service in mind.
  • Page 27 INSTALLATION – SOLAR STORAGE TANK TANK WATER SUPPLY If the water heater is supplied with water from a tank supply and a minimum water supply pressure of 200 kPa at the water heater cannot be achieved, then a pressure pump system must be installed to allow the solar circuit system to operate.
  • Page 28: Installation – Solar Storage Tank

    INSTALLATION – SOLAR STORAGE TANK CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A solar water heater should not be installed as part of a circulated hot water flow and return system in a building. The benefits of solar gain will be significantly reduced and energy gained from the sun lost through the pipe work.
  • Page 29 INSTALLATION – SOLAR STORAGE TANK ANODE The vitreous enamel lined cylinder of the water heater is only covered by the Solahart warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is used.
  • Page 30 INSTALLATION – SOLAR STORAGE TANK DIMENSIONS AND TECHNICAL DATA Solar Direct Pumped Electric Boost Models - Single Element Model Tank Mass (kg) Storage Boost Dimensions (single mid Capacity Capacity Empty Full element) 270MDV 270 litres 140 litres 320MDV 320 litres 170 litres 410MDV 410 litres...
  • Page 31 INSTALLATION – SOLAR STORAGE TANK TYPICAL INSTALLATION (SINGLE ELEMENT) – OUTDOOR LOCATION TYPICAL INSTALLATION (SINGLE ELEMENT) – INDOOR LOCATION Solar Direct Pumped Electric Boost Models - Single Element Solar Direct Pumped Electric Boost Models - Single Element Typical Installation Solar Storage Tank Typical Installation Solar Storage Tank...
  • Page 32 If the cylinder is damaged as a result of mounting the solar control unit to the “Saddling - Pipe Work” jacket, any resultant faults will not be covered by the Solahart warranty (refer to on page 29).
  • Page 33 INSTALLATION – SOLAR CONTROL UNIT SOLAR STORAGE TANK WITH RAISED SOLAR HOT INLET Numbers in parentheses refer to items on diagram on page 34 for single element models. To mount the solar control unit and connect the solar cold pipe on a single element model with a raised solar hot inlet (and raised heating unit): ...
  • Page 34: Installation – Solar Control Unit

    INSTALLATION – SOLAR CONTROL UNIT Note: The solar control unit automatically controls the flow rate through the collector circuit. This is achieved via the hot and cold sensors and differential controller programming providing control over the operation of the circulator. There is no provision for nor is adjustment to the solar control unit required. from solar to solar collectors...
  • Page 35 INSTALLATION – SOLAR COLLECTORS SOLAR COLLECTOR LOCATION Consideration must be given to the position of the solar collectors in relation to the solar storage tank. There are limitations on the maximum length of the solar hot and solar cold pipes between the solar storage tank “Solar Storage Tank Location”...
  • Page 36 A Variable Pitch frame can be installed to increase the angle of inclination of the collectors used in a Streamline water heater installation. This type of frame should be used if the roof pitch either varies by more than 20° from the optimum angle or is less than 10°.
  • Page 37: Installation – Solar Collectors

    INSTALLATION – SOLAR COLLECTORS MAXIMUM NUMBER OF COLLECTORS The maximum number of solar collectors which may be installed for each tank size is: LCS, TBT200 (T) Tank Model non-selective surface selective surface 270MDV 320MDV 410MDV PIPE LENGTHS The solar hot and solar cold pipes between the solar storage tank and the solar collectors shall: ...
  • Page 38 INSTALLATION – SOLAR COLLECTORS WARNING: Plumber – Be Aware  The solar hot and solar cold pipes between the solar storage tank and the solar collectors MUST BE of copper. All compression fittings must use brass or copper olives.  The full length of the solar hot and solar cold pipes MUST BE insulated.
  • Page 39 INSTALLATION – SOLAR COLLECTORS Maximum height to collectors The maximum height of a solar Streamline installation, from the solar controller (circulator) to the top of the solar collectors, is determined by the maximum recommended total pipe length for the system and the water supply pressure.
  • Page 40 CONNECTIONS – PLUMBING All plumbing work must be carried out by a qualified person and in accordance with the requirements of the Standard AS/NZS 3500.4, and all local codes and regulatory authority requirements. In New Zealand, the installation must conform with Clause G12 of the New Zealand Building Code. Warning: Certain types of plastic pipe, such as Poly-butylene pipe, are not suitable to be used as a hot water pipe between: ...
  • Page 41 CONNECTIONS – PLUMBING A disconnection union must always be provided at the cold water inlet, solar cold water outlet, solar hot water inlet and hot water outlet on the water heater to allow for disconnection of the water heater. This water heater has either a plastic dip tube or fitting liner in the inlet and outlet fittings (see diagram).
  • Page 42: Connections – Plumbing

    CONNECTIONS – PLUMBING RELIEF VALVE DRAIN DN15 copper drain lines must be fitted to the temperature pressure relief valve and expansion control valve (if one is installed). Connect the drain lines to the valves using disconnection unions. The drain line from the valve to the point of discharge should be as short as possible, have a continuous fall all the way from the water heater to the discharge outlet and have no tap, valves or other restrictions in the pipe work.
  • Page 43 CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
  • Page 44 CONNECTIONS – ELECTRICAL THERMOSTAT SETTING The thermostat is adjustable from 60°C to 70°C. The thermostat is adjusted by turning the adjuster anticlockwise to decrease the temperature setting and clockwise to increase the temperature setting. Only adjust the temperature setting when the isolating switch is switched off at the switchboard. For reasons of safety and economy, we advise the thermostat be set at the lowest temperature that will provide sufficient hot water during periods when boosting is required.
  • Page 45: Connections – Electrical

    CONNECTIONS – ELECTRICAL BOOSTER CONTROL The isolating switch installed in the electrical meter box for the solar storage tank should be left switched on. Leaving the isolating switch switched on will also provide a sufficient period of time each day for the booster heating unit to operate, if required, to satisfy the requirements of AS 3498.
  • Page 46 CONNECTIONS – ELECTRICAL WIRING DIAGRAM – TIMER CONTROL SWITCH Switchboard Switchboard Switchboard CONTINUOUS EXTENDED OFF-PEAK EXTENDED OFF-PEAK POWER SUPPLY POWER SUPPLY POWER SUPPLY (timer with rechargeable battery) Timer Timer Terminal Block Terminal Block TIMER WITHOUT CONTACTOR TIMER WITH CONTACTOR (if required) TIMER WIRING DIAGRAMS ELECTRIC BOOSTED DIRECT SOLAR WATER HEATER...
  • Page 47 If there is a risk of freezing, then it is necessary to drain the solar collectors and solar flow and return “Draining the Solar Collectors” pipe work (refer to on page 50).  “Terms of the Solahart Warranty” Refer to on page 53.
  • Page 48 COMMISSIONING BLEEDING THE SOLAR COLLECTORS Upon completion of the installation, it is necessary to purge the air from the collector circuit. To purge air from the collector circuit:  Ensure the water heater is full of water and all of the hot taps are turned off.
  • Page 49: Commissioning

    COMMISSIONING If the red LED does continue to emit a rapid pulse for longer than ten (10) minutes, this may indicate water is not circulating through the solar collectors and solar circuit:  switch off the electrical supply at the power outlet to the solar control unit ...
  • Page 50: Draining The Solar Collectors

    DRAINING THE SOLAR COLLECTORS To drain the solar collectors and the solar hot and solar cold pipe:  Cover the solar collectors with an opaque material.  Open a hot water tap and allow the water to run for five minutes immediately prior to draining the solar collectors.
  • Page 51 This page is intentionally blank.
  • Page 52 This page is intentionally blank.
  • Page 53 2.1 The decision of whether to repair or replace a faulty component is at Solahart’s sole discretion. 2.2 If you require a call out and we find that the fault is not covered by the Solahart warranty, you are responsible for our standard call out charge.
  • Page 54 3. WHAT IS COVERED BY THE SOLAHART WARRANTY FOR THE WATER HEATERS DETAILED IN THIS DOCUMENT 3.1 Solahart will repair or replace a faulty component of your water heater if it fails to operate in accordance with its specifications as follows:...
  • Page 55: Warranty

    If a Solahart unit Tank Serial No Date of manufacture Collector Serial No’s Comments Installer Certification – I certify this installation has been installed and tested in accordance with Solahart Industries Pty Ltd specifications Signature: Installer: Customer: Date White Copy: Head Office...
  • Page 56: Solahart Offices

    + 1 800 621 5622 For SERVICE Telephone - 1800 638 011 Facsimile International: + 1 334 260 4672 or your nearest Solahart Dealer For Sales Telephone - 1300 769 475 or your nearest Solahart Dealer Revision Date: 2013 July...