1.3 GENERAL CHARACTERISTICS
Power supply
Total power absorption
Water supply
Load capacity
Noise level
Class
* Declared consumption [BIO AAB programmes]
- Water - Energy - Duration of cycle ⇒
* Example of programme declared to the various consumer institutes (electronic models).
1.4 FIELD OF APPLICATION
Washing system
Control system
Water fill level
Water heating
Temperature control
Drying system
Safety systems
Alarms
1.5 ELECTRONIC MODULE
Power board
Comandi / Visualizzazione
SOI/TD - PR
230 V / 50 Hz (limits 187−254 V)
⇒
2300 W (with 2100 W heating element)
⇒
Min. / Max. Pressures: 5 − 80 N/cm
⇒
9 place settings for 45cm and 12 place settings for 60cm
⇒
db 50 / 56 (A) sound pressure (electromechanical)
⇒
db 46 / 50 (A) sound pressure (electronic)
⇒
[AAA] - [AAB] (electronic models)
⇒
CONTINUOUS (electromechanical)
⇒
CONTINUOUS /IMPULSE OPERATION (electronic)
⇒
TIMER (electromechanical)
⇒
CONTROL BOARD (electronic)
⇒
PRESSURE SWITCH CONTROL (electromechanical)
⇒
PRESSURE SWITCH+SOFTWARE CONTROL (electronic)
⇒
HEATING ELEMENT IN PROTECTIVE TUBE
⇒
THERMOSTATS (electromechanical)
⇒
NTC TEMPERATURE SENSOR (electronic)
⇒
NORMAL DRY (electromechanical)
⇒
ACTIVE DRY (electronic)
⇒
TURBO DRY (electronic)
⇒
HYDRAULIC/ELECTRICAL SYSTEMS (electromechanical)
⇒
TOTAL PROTECTION: HYDRAULIC/ELECTRICAL +
⇒
SOFTWARE (electronic)
SOFTWARE SYSTEM WITH VISUAL DISPLAY (electronic)
⇒
MAIN OPERATIONAL CONTROL (built-in microprocessor)
⇒
USER-MACHINE INTERFACE
⇒
6/32
14Lt. - 1,10 KWh - 150 Min
2
599 38 72-30