Using your LinkStation

Restoring Factory Defaults

To initialize the LinkStation to its factory defaults, follow the procedure below.
For LS-VL, LS-XHL, LS-CHL, LS-WVL, LS-WXL, LS-WSXL LinkStation models
1
Move the power switch to the OFF position to shut down the LinkStation.
2
Move the power switch to the ON position while holding down the function button. The
function button will flash blue for 1 minute.
3
While the function button is flashing blue, press it again. The status LED will flash blue. It will
start flashing amber when initialization begins (2 - 3 minutes).
For LS-QVL LinkStation model
1
Hold down the Power button for three seconds to shut down the LinkStation.
2
Turn on the Power button while holding down the Function button. The Function LED flashes
blue (for about one minute).
3
While the Function LED is flashing blue, press the Function button one more time. This starts
the initialization process. During initialization, the Power LED flashes amber.
LinkStation User Manual
Function Button
Power Button
Power LED
Function Button
Function LED