Specifications
Temperature Range
Operating:
Storage:
Temperature coefficient:
Operating humidity:
Operating altitude:
Climatic Class:
Protection type
Case:
Battery door:
Electromagnetic compatibility:
Safety:
Measurement time:
Maximum overload:
Batteries:
Battery life span:
Dimensions:
Weight with batteries:
Memory:
Interference Voltage DC + AC (U
Measuring method:
Measuring
Range
1...50 V
Measuring sequence:
Internal resistance:
Maximum overload:
42
0 °C to +35 °C (+32 °F to +95 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
±0.1 % of rdg / °C (below 18 °C and above 28 °C)
<95% RH non-condensing
2000 m
C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH
IP56
IP40
Complies with IEC61326-1: Portable
Complies with IEC 61010-1: CAT None, Pollution Degree 2
6 seconds, typical
250 V
6 x 1.5v, AA LR6 Alkaline
>3000 measurements, typical, RH + RE < 1 kOhm
>6000 measurements, typical, RH + RE > 10 kOhm
240 mm x 180 mm x 110 mm (9.5 in x 7.1 in x 4.4 in)
1.52 kg (3.35 lb)
Internal memory storage up to 1500 records
accessible via USB port
ST
fullwave rectification
Display
Resolution
Range
0.0...50 V
0.1 V
approximately 4 measurements/s
approximately 1.5 MΩ
U rms = 250 V
(in association with misuse)
rms
) Measurement
Frequency Range
DC/AC 45...400 Hz sine
Accuracy
± (5% of rdg +5 digit)