TRAINING MANUAL
The diagnostic test mode is for service testing only. Do not activate the heater manually
with the door open or it will trip the thermostat attached to the heater.
1.
Dryer must be in standby mode. (Plugged in, turned off)
2.
Press and hold MORE TIME and LESS TIME, then press power.
3.
Press START/PAUSE to advance to the next test.
4.
Unplug the dryer for one minute after using the diagnostic mode.
NOTE:
During Test 4, The Steam Generator pump will flood the dryer if allowed
to run very long. This is normal, so do not stay on this test very long.
DLEX8388WM
DIAGNOSTIC TEST MODE
Page 25
DLEX8377WM
STEAM DRYER