BATTERY
◉ INSPECTION OF BATTERY SOLUTION LEVEL
MF(Maintenance Free) battery of airtight type is
used for this motorcycle.
It is not necessary to inspect or supplement bat-
tery fluid.
The battery is located behind the right frame
cover.
However, have your dealer check the charging
condition of battery periodically.
To remove the battery, loosen the screw
unhook the hook
frame cover.
After remove the frame cover, can pull it out as
to take off the starter relay and fuse and sepa-
rate the battery support.
,
and remove the right
●
Do not remove absolutely airtight cover
as airtight type battery.
●
Keep after separate at the motorcycle
for the minimum of self electric dis-
charge and electric leakage when don t
use for a long time.
●
Remove the ( ) negative terminal when
keep intact at the motorcycle.
◉ CLEAN OF BATTERY TERMINAL
Clean the battery terminal when it is dusty or
rusted.
1. Set the ignition switch OFF position.
2. Disassemble the battery cover, disassemble
the ( )positive battery wire after the ( )neg-
ative battery wire.
Remove the battery.
3. Clean the terminal.
If there is white dust, clean it with warm water.
4. Assemble the battery wires and grease the
terminal lightly.
,
●
Keep the battery away from fires.
●
When disassemble the battery wire,
take off � terminal first with the ignition
switch OFF position.
When assemble, � terminal first.
●
Fasten certainly the battery wires.