Qmark MUH Series Installation & Maintenance Instructions Manual

Qmark MUH Series Installation & Maintenance Instructions Manual

Muh series modular unit heaters

Advertisement

Available languages

Available languages

MUH Series
Modular Unit Heaters
Installation & Maintenance Instructions
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered
Products. You have made a wise investment selecting the highest quality product in the heating industry.
Please carefully read and follow the installation and maintenance directions shown in this manual. You
should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the
industry's leader in design, manufacturing, quality and service.
Read Carefully -
These instructions are written to help
you prevent difficulties that might arise during installation
of heaters. Studying the instructions first may save you
considerable time and money later. Observe the following
procedures, and cut your mounting time to a minimum.
To reduce risk of fire or electric shock:
1. To prevent electrical shock, disconnect all power coming to
heater at main service panel before wiring or servicing.
2. All wiring must be in accordance with the National and Local
Electrical Codes and the heater must be grounded as a pre-
caution against possible electric shock.
3. Verify the power supply voltage coming to heater matches the
ratings printed on the heater name plate before energizing.
4. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces.
WARNING
!
SAVE THESE INSTRUCTIONS
... The Employees of
Marley Engineered Products
5. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock,
fire,or damage to the heater.
6. To prevent a possible fire, do not block air intakes or exhaust
in any manner. Keep combustible materials, such as crates,
drapes, etc., away from heater. Do not install behind door,
furniture, towels, or boxes.
7. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint or flammable liquids are
stored.
8. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
9. This heater is not approved for use in corrosive atmospheres
such as marine, green house or chemical storage areas.
1
FILE #E21609

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Qmark MUH Series

  • Page 1 MUH Series Modular Unit Heaters FILE #E21609 Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating industry.
  • Page 2: Mounting The Heater

    IMPORTANT CAUTION CAUTION ALL BUILT-IN THERMOSTATS: IF THE HEATER IS USED TO THE HEATER MUST BE MOUNTED AT LEAST 7' (2134mm) PREVENT PIPING OR LIQUIDS FROM FREEZING, AND IF ABOVE THE FLOOR TO PREVENT ACCIDENTAL CONTACT THE THERMOSTAT IS SET BELOW 45° F (7°C), THE FAN WITH THE FAN BLADE WHICH COULD CAUSE INJURY.
  • Page 3: Branch Circuit

    to direct the heated air in the desired direction. When the Install four threaded mounting rods in the threaded holes heater is installed for horizontal discharge, the louvers should and and secure in place using lock nuts. direct the air either straight ahead or downward. Directing Securely attach the four mounting rods to the ceiling.
  • Page 4: Wiring Connections For Three-Phase Power

    7. Each heater has a wiring diagram affixed to the inside of The relay (contactor) lead wire “A1” must be moved from the access door. Consult this diagram before making the end terminal of the power terminal block (terminal clos- any field connections.
  • Page 5: Control Terminal Board

    3 PHASE BLOCK 3 PHASE BLOCK 3 PHASE BLOCK 3 PHASE BLOCK FACTORY-WIRED FOR SINGLE-PHASE POWER FIELD-WIRED FOR THREE-PHASE POWER Figure 3b. Wiring Connections for Single-Phase and Three -Phase Power (MUH158) CONTROL WIRING WARNING 2-STAGE INTERNAL LINE VOLTAGE IS PRESENT ON SOME OF THE TERMINALS THERMOSTAT REMOTE SUMMER FAN SWITCH (MRFS-1)
  • Page 6 Table 4. Specifications Mounting Wiring Basic Model Height Width Depth Weight Compartment in (mm) in. (mm) in. (mm) lbs. (kg) Volume MUH0381 27 (12.2) MUH0321 27 (12.2) MUH0371 27 (12.2) MUH0341 30 (13.6) MUH0581 27 (12.2) MUH0521 27 (12.2) 90 in (406.4) (355.6) (190.5)
  • Page 7 IMPORTANT INFORMATION NAMEPLATE 0395 MODEL NO. DATE CODE MUH0321 MFG. NO. VOLTS AC KILOWATTS PHASE MIN. SUPPLY 60 HZ CIR. AMPACITY 208 / 240 2.2 /3 MAX. FUSE MOTOR CONTROLS CUSTOMER NO 208/240 208/240 MINIMUM MOUNTING CLEARANCE FLOW SIDE BACK CEILING FLOOR HORIZ.
  • Page 8: Limited Warranty

    LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration;...
  • Page 9 Serie MUH Unidades de Calentadores Modulares EXPEDIENTE No. E21609 Instrucciones de Instalación y Mantenimiento Estimado propietario: ¡Felicitaciones! Gracias por comprar este nuevo calentador fabricado por Marley Engineered Products. Usted ha efectuado una sabia inversión al seleccionar el producto de la más alta calidad en la industria de calefacción.
  • Page 10 IMPORTANTE PRECAUCION PRECAUCION TODOS LOS TERMOSTATOS INCORPORADOS: SI EL EL CALENTADOR DEBE SER INSTALADO POR LO MENOS CALENTADOR ES UTILIZADO PARA PREVENIR QUE 7’(2134 mm) SOBRE EL PISO PARA PREVENIR QUE EL TUBERIAS O LIQUIDOS SE CONGELEN, Y SI EL CONTACTO ACCIDENTAL CON LAS HOJAS DEL ABANICO TERMOSTATO SE AJUSTA A MENOS DE 45°F (7°C), EL PUEDA CAUSAR LESIONES.
  • Page 11 Cuando el calentador ha sido instalado para descarga horizontal, las Instale cuatro varillas de montaje con rosca en los huecos con persianas deben dirigir el aire ya sea hacia el frente o hacia abajo. rosca y asegure utilizando tuercas de seguridad. Dirigir el aire hacia arriba puede causar que el aire caliente se Pegue firmemente las cuatro varillas de montaje al techo.
  • Page 12 Cada calentador tiene un diagrama de cableado pegado en minal “A” del bloque de terminales inferior (terminal central). la parte interior de la puerta de acceso. Consulte este dia- El modelo MUH158 (Figura 3b) tiene dos bloques de terminales tri- grama antes de hacer cualquier conexión de campo.
  • Page 13 BLOQUE TRI-FASICO BLOQUE TRI-FASICO 3 PHASE BLOCK 3 PHASE BLOCK BLOQUE TRI-FASICO BLOQUE TRI-FASICO 3 PHASE BLOCK 3 PHASE BLOCK CABLEADO DE FABRICA PARA ALIMENTACION MONO-FASICA CABLEADO DE CAMPO PARA ALIMENTACION TRI-FASICA FACTORY-WIRED FOR SINGLE-PHASE POWER FIELD-WIRED FOR THREE-PHASE POWER Figura 3b.
  • Page 14 Tabla 4. Especificaciones Altura Ancho Profundidad Peso de Volumen del Modelo pulgadas pulgadas pulgadas Instalación Compartimiento Básico Nº (mm) (mm) (mm) lbs. (kg) de Cableado MUH0381 27 (12.2) MUH0321 27 (12.2) MUH0371 27 (12.2) MUH0341 30 (13.6) MUH0581 27 (12.2) MUH0521 27 (12.2) 90 in...
  • Page 15: Informacion Importante

    INFORMACION IMPORTANTE PLACA DEL FABRICANTE 0395 MODELO NO. CODIGO DE FECHA MUH321 MFG. NO. VOLTS AC KILOWATTS FASE AMPACIDAD MIN. DE 60 HZ ALIMENTACION DE CIR. 208 / 240 2.2 /3 MAX. FUSIBLE MOTOR CONTROLES CLIENTE Nº 208/240 208/240 FLUJO DE ESPACIO MINIMO DE INSTALACION AIRE LADO...
  • Page 16: Garantia Limitada

    GARANTIA LIMITADA Todos los productos fabricados por Marley Engineered Products están garantizados contra defectos de mano de obra y materiales durante un año a partir de la fecha de instalación, excepto los elementos calefactores que están garantizados contra defectos en mano de obra y materiales durante cinco años a partir de la fecha de instalación.
  • Page 17 S é r i e M U H Radiateurs modulaires Homologués U.L. Notice d’installation et d’entretien Cher utilisateur, Félicitations ! Nous vous remercions d'avoir fait l'acquisition de ce nouveau radiateur fabriqué par Marley Engineered Products. Vous avez fait un bon investissement en choisissant un appareil de qualité imbattable.
  • Page 18: Avis Importants

    AVIS IMPORTANTS MISE EN GARDE MISE EN GARDE MONTER LE RADIATEUR À 213.4cm (7 PIEDS) MINIMUM POUR TOUS LES APPAREILS À THERMOSTATS INTÉGRÉS : AU-DESSUS DU SOL AFIN D'EMPÊCHER TOUT CONTACT SI LE RADIATEUR SERT À EMPÊCHER DES TUYAUX OU ACCIDENTEL AVEC LES PALES DU VENTILATEUR, CE QUI DES LIQUIDES DE GELER, ET SI LE THERMOSTAT EST POURRAIT PROVOQUER DES BLESSURES.
  • Page 19 tLorsque le radiateur est installé pour une décharge horizon- Fixer solidement les quatre tiges filetées au plafond. (Se tale, les persiennes doivent diriger l'air tout droit ou vers le bas. reporter au tableau 1 où figurent les distances à respecter L'air dirigé...
  • Page 20 Un schéma de câblage est collé sur la face interne de la Le fil du relais (contacteur) "A1" doit être déplacé de la borne porte d'accès. Se reporter au schéma avant d'effectuer un d'extrémité du bornier de puissance (borne la plus proche du quelconque raccordement sur le site.
  • Page 21 BONIER DE TRIPHASÉ BONIER DE TRIPHASÉ BONIER DE TRIPHASÉ BONIER DE TRIPHASÉ CÂBLAGE USINE POUR ALIMENTATION EN MONOPHASÉ CÂBLAGE SUR SITE POUR ALIMENTATION EN TRIPHASÉ Figure 3b. Câblage pour alimentation en monophasé et en triphasé (MUH158) CÂBLAGE DE COMMANDE AVERTISSEMENT LA TENSION SECTEUR EST PRÉSENTE SUR CERTAINES THERMOSTAT INTERNE À...
  • Page 22 Table 4. Specifications Poids Volume du Modèle de Hauteur Largeur Profondeur monté Compartiment base N° po (mm) po (mm) po (mm) kg (livres) de Câblage MUH0381 27 (12.2) MUH0321 27 (12.2) MUH0371 27 (12.2) MUH0341 30 (13.6) MUH0581 27 (12.2) MUH0521 27 (12.2) 90 in...
  • Page 23 RENSEIGNEMENT IMPORTANT PLAQUE DE FIRME 0395 MODEL NO. DATE CODE MUH321 MFG. NO. VOLTS AC KILOWATTS PHASE MIN. SUPPLY 60 HZ CIR. AMPACITY 208 / 240 2.2 /3 MAX. FUSE MOTOR CONTROLS CUSTOMER NO 208/240 208/240 MINIMUM MOUNTING CLEARANCE FLOW SIDE BACK CEILING...
  • Page 24: Garantie Limitée

    GARANTIE LIMITÉE Tous les produits mentionnés dans la présente notice sont garantis contre tout vice de matière et de construction pour une durée d'une année à partir de la date de montage, à l'exception des éléments de chauffage qui sont garantis contre tout défaut de matière et de construction pour unedurée de cinq années à...