Marantz PMD510 User Manual

Marantz PMD510 User Manual

Fully independent double cassette deck
Hide thumbs Also See for PMD510:

Advertisement

CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
The lightning flash with arrowhead symbol, within
an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of suffi-
cient magnitude to constitute a risk of electric shock
to persons.
The exclamation point within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the ap-
pliance.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE
BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
ATTENTION: POUR ÉVITER LES CHOCS ÉLECTRIQUES,
INTRODUIRE LA LAME LA PLUS LARGE DE LA
FICHE DANS LA BORNE CORRESPONDANTE DE LA
PRISE ET POUSSER JUSQU'AU FOND.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMD510 and is the answer not in the manual?

Questions and answers

Summary of Contents for Marantz PMD510

  • Page 1 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage"...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS READ BEFORE OPERATING EQUIPMENT This product was designed and manufactured to meet strict quality 12. Grounding or Polarization — Precautions should be taken so and safety standards. There are, however, some installation and that the grounding or polarization means of an appliance is not operation precautions which you should be particularly aware of.
  • Page 3: Note To Catv System Installer

    FIGURE 1 EXAMPLE OF ANTENNA GROUNDING ACCORDING TO NATIONAL ELECTRICAL CODE INSTRUCYIONS CONTAINED IN ARTICLE 810 -"RADIO AND TELEVISION EQUIPMENT" ANTENNA LEAD IN WIRE GROUND CLAMP ANTENNA DISCHARGE UNIT (NEC SECTION 810-20) ELECTRIC SERVICE EQUIPMENT GROUNDING CONDUCTORS (NEC SECTION 810-21) GROUND CLAMPS POWER SERVICE GROUNDING ELECTRODE SYSTEM...
  • Page 4 DOLBY NR CONT. HIGH NORM CASCADE DUBBING SPEED /CD SYNC REMOTE ENABLE PITCH PITCH CONT. CONT. FULLY INDEPENDENT DOUBLE CASSETTE DECK PMD510 EJECT EJECT -20 -10 +6 db -20 -10 +6 db POWER OFF B C OFF B C MEMO RESET...
  • Page 5 In the continuous mode, Well A will play (or record) side one, autoreverse, play (or record) side two, and then automatically Thank you for selecting the Marantz Model PMD510 Independent switch to Well B, which will play (or record) side one, autoreverse, Double Cassette Deck for your audio system.
  • Page 6: Rear Panel Connections

    Connect the output of the remote control to the Only use this button when both decks are in the STOP mode. When RC-5 input of the PMD510. The RC-5 output of the PMD510 may the CONT button is pressed again, the indicator will go out, and be connected to the RC-5 input of other machines for multiple- continuous mode is cancelled.
  • Page 7: Operation

    RESET buttons DUBBING SPEED INDICATORS Pressing this button will reset the counter time to 00.00 (0 minutes, One of these indicators will light when the NORM or HIGH speed dubbing buttons u are pressed. 0 seconds) QMS (QUICK MUSIC SEARCH) BUTTON REMOTE ENABLE INDICATOR The QMS feature allows you to search in either direction for a When using an RC-5 remote control system such as the RC5PMD...
  • Page 8: Parallel Recording

    PMD510. Chrome or Metal tapes have superior performance button r to cancel dubbing. Both wells will enter 6. Press STOP compared to Normal Tapes. The PMD510 can sense which kind of the Stop mode. tape is being used, and will automatically adjust bias, EQ, etc.
  • Page 9: Cd Synchro Recording

    RC-5 REMOTE E input jack on the rear panel runs from the EXTENSION REMOTE F output jack on the rear panel of the PMD510, from the REMOTE output jack on the rear panel of of the first machine, to the EXTENSION REMOTE F input jack on the Marantz CD player.
  • Page 10: Care And Maintenance

    Marantz Authorized Service Center nearest you. In many cases, the dealer where you purchased your Marantz unit may be equipped to provide service. Please include the model and serial number of your unit together with a copy of your purchase receipt and a full description of what you feel is abnormal in its behavior.
  • Page 11: Troubleshooting

    Rec / Play Head ......Hard Metal Alloy (Rotary) If the fault cannot be remedied after the following check, please Erase Head ..........Dual Gap Ferrite consult your dealer or nearest MARANTZ service agent. Recording / Erasure System ......AC 105 kHz Bias The tape does not travel.
  • Page 12 REAR PANEL CONNECTIONS PMD510 DECK B DECK A REMOTE LINE LINE RC-5 I N P U T I N P U T SELECT SELECT LINE Your amplifier or receiver #1 TAPE Your amplifier or receiver #2 Figure 2...
  • Page 13: Cascade Operation

    CASCADE OPERATION PMD510 #1 DECK B DECK A REMOTE LINE LINE RC-5 I N P U T I N P U T SELECT SELECT PMD510 #2 DECK B DECK A REMOTE LINE LINE RC-5 I N P U T I N P U T...
  • Page 14 Metal tape detection hole tape detection hole Figure 4 Figure 5 Figure 6 Figure 7...
  • Page 15 is a registered trademark. Printed in Japan 98 / 06 SK 456T851214...
  • Page 16 Model PMD510 User Guide Stereo Double Cassette Deck...

Table of Contents

Save PDF