OPENINGFOR HANGING CLEANER IN STORAGE AREA ON/OFFSWlTCH COVERLATCH NOZZLE HOSE- HANDLE -GRIP - CARRYING HAND ADJUSTMENT LEVER...
Page 3
TO ATTACH HANDLE TO CLEANER 1. Remove tape and screw from h an d 1 e s o c k e t. Set screw aside for later use. 3. Connect electric plug from bottom of handle to electric plug projecting from handle socket.
Page 4
SUCTION ADJUSTMENT (Fig. 1) Set the dial to MEDIUM. This will be the correct setting for the majority of rugs. If your HOOVER cleaner seems hard to push, move the dial toward the LOW position. For low pile, sculptured or multi-level rugs it may be necessary to move the lever toward HIGH for most effective cleaning.
Page 5
FIG. 3 FOR BEST RESULTS, TIP THE CLEANER BACK ON ITS REAR WHEELS AND ADJUST THE LEVER BY HAN& (FIG. 2) NOTE: When removing loose dirt from hard surface floors, adjust the cleaner to the NORMAL position. The INDOOR/OUTDOOR setting on the c 1 e a ne r lowers’ the nozzle to the carpet for effective cleaning of INDOOR/ OUTDOOR carpet.
THE CLEANING TOOLS (See Page 4 for setting Suction Control Dial when using tools.) The cleaning tools have many uses. Some are listed below: 1. TUFFLEX HOSE Double vinyl reinforced with nylon mesh for long, trouble-free life. The light flexible hose has a vinyl tab, so it can be hung on the cleaner or on a hook in a closet.
Page 7
TO CONNECT HOSE TO CLEANER Insert hose connector in opening below dial. Turn hose connector in either direction until it locks in place. TO CONNECT TOOLS To connect the cleaning tools to either the telescoping wand or hose, press down on the plastic latch and fit the attachment into place making sure the button on the attachment is locked in place.
HELPFUL HINTS EASY TO CARRY Use the convenient carrying handle for carrying your Hoover cleaner. (See Fig. 1) When lifting the cleaner from one surface to another, lift it as shown in Fig. 2. DON’T PICK UP TACKS Hard, sharp objects should not be picked up by the cleaner.
Page 9
Authorized Hoover Dealer (listed in Yellow Pages of Telephone Directory under “ V a c u u m Cleaners”- Hoover) or f r o m Hoover Factory S e r v i c e Stations (-jOJ@ listed on service page of this book.
Hoover belt. Some other belts on the market, not manufactured under Hoover design and quality controls, do not operate the agitator correctly and create undue stress which will damage your Hoover cleaner.
HOW TO REPLACE THE BELT 1. Remove cord from electrical outlet. 2. Turn cleaner over. Remove metal plate on bottom of cleaner by pushing latches toward the out- side of cleaner. Lift plate to re- lease it from wire holders. 3, Push latches, that hold agitator, in and toward center of cleaner until they are free.
Page 12
THE BRUSHES When brushes are worn and bris- tles do not touch the edge of a card held across the nozzle, they should be replaced. Always replace both brushes at the same t i m e t o m a i n t a i n c l e a n i n g efficiency.
Page 13
FORE, DO NOT ADD LUBRICANT TO EITHER MOTOR BEARING. The agitator is equipped with two ball bearings that should be lubricated periodically. This should be done by The Hoover Factory Service Station, as listed in this booklet, or the Authorized Hoover Warranty Service Dealer, as...
Page 16
Your Hoover appliance is guaranteed for normal household use against original defects in material and workmanship for a period of one year from date of purchase. This guarantee covers labor and parts required to place this appliance in correct operating condition.
Need help?
Do you have a question about the DIAL-A-MATIC 1130 and is the answer not in the manual?
Questions and answers