CSE-M35S/CSE-M35T1
Mobile Rack
USER'S GUIDE
1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Supero CSE-M35S and is the answer not in the manual?

Questions and answers

Summary of Contents for Supero Supero CSE-M35S

  • Page 1 ® UPER CSE-M35S/CSE-M35T1 Mobile Rack USER'S GUIDE...
  • Page 2 UPER CSE-M35S/CSE-M35T1 User's Guide Table of Contents Packaging List ...................... 3 Technical Specifications ..................4 Jumper Settings ....................5 Installation Procedures ..................7...
  • Page 3: Packaging List

    Packing List CSE-M35S/CSE-M35T1 Supermicro’s CSE-M35S/CSE-M35T1 Mobile Rack Series offers the cutting edge technology with greater flexibility. The CSE-M35T1 supports five Se- rial ATA hot-swappable hard drives that yield a unparalleled storage capac- ity without compromising productivity by eliminating possible system down- time.
  • Page 4: Technical Specifications

    UPER CSE-M35S/CSE-M35T1 User's Guide 2. Technical Specifications Occupancy Three (3) 5.25" Drive Bays Capacity Five (5) 1" SCA Ultra320/160 Hard Drives with SAF-TE built-in (*CSE-M35S only) Five (5) 1" Host Receptacle Connectors, SATA hot-swap hard drives (*CSE-M35T-1 only) Cooling One (1) 90mm (9cm) Exhaust Fan Subsystem System *Fan Fail Detection LED and Alarm...
  • Page 5: Jumper Settings

    Jumper Settings 3. Jumper Settings A. Jumper Settings for the CSE-M35S (SCSI): Jumper Description Setting JP18 Buzzer Reset Closed: Enable, Open: Disable (*Default) JP21 SCSI Termination Closed: Enable (*Default), Open: Disable JP24 SCSI ID Selection 1-2: SCSI Ids: 0,1,2,3,4 (*Default), 2-3: SCSI Ids: 9,10,11,12,13 JP29 GEM 318 IDs...
  • Page 6 UPER CSE-M35S/CSE-M35T1 User's Guide B. Jumper Settings for the CSE-M35T1 (SATA): Jumper Description Setting JP18 Buzzer Reset Closed: Enable, Open: Disable (*Default) JP25 Overheat Temperature Open: 45 1-2: 50 C (*Default), 2-3: 55 JP26 Act#1-Act#5 Connect this header to CBL-0057 (SATA LED Cable) JP28: Fan Sense...
  • Page 7: Installation Procedures

    Installation Procedures 4. Installation Procedures (*Note: For the CSE-M35S: 1. SCSI IDs are assigned automatically by the backplane. Do not set IDs manually on the drives. See the previous section for SCSI ID jumper settings. 2. SCSI termination is enabled by default on the SCSI backplane.) A.
  • Page 8 UPER CSE-M35S/CSE-M35T1 User's Guide 2. Swing the handle outward and pull out the unit (as shown below:) 3. Mount a drive in a carrier (as shown below:)
  • Page 9 Installation Procedures B. Accessing the Exhaust Fan: 1.Push the tabs located on both sides of the unit (as shown be- low:) 2. Pull out the fan (as shown below:) (*Note: For the SC-942 Chassis, the CSE-M35 Rear Exhaust Fan should not be used. Instead, the hot-swappable 120mm Chassis Fans included with the SC-942 Chassis should be connected to the Backplane of the CSE-M35S/CSE-M35T1 Mobile Rack.)
  • Page 10 UPER CSE-M35S/CSE-M35T1 User's Guide C. Accessing the Drive Backplane: 1. Unscrew the screw located on the side of the unit (as shown below:) 2. Pull out the Rear Bracket (as shown below:) 3. Access the Backplane (as shown below:)