High-density small form factor rack-mount server (58 pages)
Summary of Contents for Cisco UCS C24
Page 1
Cisco UCS C24 Server Installation and Service Guide Covers Server Generation M3 February 18, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 OL-26647-01 Text Part Number:...
Page 2
Cisco and/or its affiliates in the United States and certain other countries. Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks.
Procedure 2: Use Recovery Jumper and recovery.cap File 2-16 Using the Clear CMOS Header CN14 2-17 Maintaining the Server C H A P T E R Server Monitoring and Management Tools Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 4
Replacing a SuperCap Power Module (RAID Backup Unit) 3-41 Replacing a Cisco USB Flash Drive 3-43 Overview of the Pre-Loaded 16-GB Cisco USB Flash Drive 3-43 Enabling a Pre-Loaded Cisco USB Flash Drive Virtual Drive 3-43 Cisco UCS C24 Server Installation and Service Guide...
Page 5
Contents Booting a Pre-Loaded Cisco USB Flash Drive Virtual Drive 3-44 Monitoring and Managing a Cisco USB Flash Drive 3-45 Internal Cisco USB Flash Drive Replacement Procedure 3-45 Enabling or Disabling the Internal USB Port 3-46 Installing a Trusted Platform Module...
Page 6
Large Form Factor 12-Drive Backplane With Expander Cabling C-20 Restoring RAID Configuration After Replacing a RAID Controller C-21 For More Information C-21 Installation for Cisco UCS Integration A P P E N D I X Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Preface This preface describes the audience, organization, and conventions of the Cisco UCS C24 Server Installation and Service Guide. It also provides information about how to obtain related documentation. Related Documentation The documentation set for the Cisco Unified Computing System (UCS) C-Series rack-mount servers is...
Preface Audience This guide is for experienced network administrators who configure and maintain Cisco servers. Documentation Feedback To provide technical feedback on this document, or to report an error or omission, please send your comments to ucs-docfeedback@external.cisco.com. We appreciate your feedback.
Page 9
å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE PÅ DISSE INSTRUKSJONENE Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 10
Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 11
Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 12
Preface Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Subscribe to What’s New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The RSS feeds are a free service.
Page 14
Preface Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 15
C H A P T E R Overview This chapter provides an overview of the Cisco UCS C24 server features. The figures in this chapter show an overview of external server features. Internal server features are illustrated in Figure 3-4 on page 3-9.
Chapter 1 Overview Figure 1-1 Cisco UCS C24 Server (Small Form Factor Drives) Front Panel Features USB 2.0 ports (two) Status LEDs (top to bottom): Network activity LED Power supply status LED Temperature status LED Fan Status LED System status LED...
Page 17
12-drive backplane with an expander. For definitions of all LED states, see Status LEDs and Buttons, page 3-2. Figure 1-2 Cisco UCS C24 Server (Large Form Factor Drives) Front Panel Features HDD01 HDD02 HDD03...
Page 18
This server supports multi-bit error protection. protection Baseboard Pilot III BMC, running Cisco Integrated Management Controller (CIMC) firmware. management Depending on your CIMC settings, the CIMC can be accessed through the 10/100/1000 Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a Cisco P81E virtual interface card.
Page 19
The server has one internal USB 2.0 socket on the motherboard that you can use with support a USB thumb drive for additional storage. The server can be ordered with an optional blank 8-GB Cisco USB Flash Drive pre-installed in the internal USB port. Cisco USB Flash The server can be ordered with an optional 16-GB Cisco USB flash drive.
Page 20
Chapter 1 Overview Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Avoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems Caution such as the Cisco UCS, which can have substantial current draw fluctuations from fluctuating data traffic patterns. Cisco UCS C24 Server Installation and Service Guide...
The minimum vertical rack space per server must be one RU, equal to 1.75 in. (44.45 mm). • Equipment Requirements The slide rails supplied by Cisco Systems for this server do not require tools for installation. The inner rails (mounting brackets) are pre-attached to the sides of the server. Slide Rail Adjustment Range The slide rails for this server have an adjustment range of 24 to 36 inches (610 to 914 mm).
Use your finger to hold the rear securing latch open when you insert the rear mounting pegs to their holes. When you release the latch, it wraps around the rack post and secures the slide-rail assembly. Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
The inner rails are pre-attached to the sides of the server at the factory. You can order Note replacement inner rails if these are damaged or lost (Cisco PID UCSC-RAIL1-I). Align the inner rails that are attached to the server sides with the front ends of the empty slide rails.
Page 27
Flange on rear of right mounting bracket Outer CMA arm attachment clip Flange on rear of outer right slide rail Continue with the “Initial Server Setup” section on page 2-8. Step 5 Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
The NIC mode is Shared LOM EXT. • Shared LOM EXT mode enables the 1-Gb Ethernet ports and the ports on any installed Cisco virtual interface card (VIC) to access the Cisco Integrated Management Interface (Cisco IMC). If you want...
Cisco card connection is not getting its IP address from a Cisco UCS Manager system because the server is in standalone mode, further DHCP requests from the Cisco card are disabled. Use the Cisco Card NIC mode if you want to connect to the CIMC through a Cisco card in standalone mode.
Page 30
MAC addresses assigned to the Cisco IMC. The MAC address printed on the label is the beginning of the range of six contiguous MAC addresses. In Cisco IMC 2.0(1) and later, you can choose whether to use IPv4 or IPv6 IP addresses by Note checking either the IPv4 or IPv6 check box.
Page 31
The default user name for the server is admin. The default password is password. Note To manage the server, see the Cisco UCS C-Series Rack-Mount Server Configuration Guide or the Cisco UCS C-Series Rack-Mount Server CLI Configuration Guide for instructions on using those interfaces.
Cisco Card interfaces are both enabled. In this mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If the system determines that the Cisco card connection is not getting its IP address from a Cisco UCS Manager system because the server is in standalone mode, further DHCP requests from the Cisco card are disabled.
See the Cisco Host Upgrade Utility Quick Reference Guide for your firmware level at the documentation roadmap link below. Your system firmware must be at minimum level 1.2 to use the Cisco Host Upgrade Utility. If Note your firmware is prior to level 1.2, you must use the methods below to update the BIOS and CIMC firmware individually.
Follow the instructions on the Exit menu screen to save your changes and exit the setup utility (or Press Step 6 F10). You can exit without saving changes by pressing Esc. Cisco UCS C24 Server Installation and Service Guide 2-14 OL-26647-01...
System would flash the BIOS image now... System would restart with recovered image after a few seconds... Wait for server to complete the BIOS update, then remove the USB thumb drive from the server. Step 6 Cisco UCS C24 Server Installation and Service Guide 2-16 OL-26647-01...
Page 37
During the BIOS update, the CIMC will shut down the server and the screen will be blank for Note about 10 minutes. Do not unplug the power cords during this update. The CIMC will power on the server after the update is complete. Cisco UCS C24 Server Installation and Service Guide 2-17 OL-26647-01...
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then Step 14 power on the server by pressing the Power button. Cisco UCS C24 Server Installation and Service Guide 2-18 OL-26647-01...
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then Step 11 power on the server by pressing the Power button. Cisco UCS C24 Server Installation and Service Guide 2-19 OL-26647-01...
Page 40
Chapter 2 Installing the Server Service Headers and Jumpers Cisco UCS C24 Server Installation and Service Guide 2-20 OL-26647-01...
Server Monitoring and Management Tools Cisco Integrated Management Interface (CIMC) You can monitor the server inventory, health, and system event logs by using the built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interfaces. See the user documentation for your firmware release at the following URL: http://www.cisco.com/en/US/products/ps10739/products_installation_and_configuration_guides_list.html...
Off—The Ethernet link is idle. Network link activity • Green—One or more Ethernet LOM ports are link-active, but there is no activity. • Green, blinking—One or more Ethernet LOM ports are link-active, with activity. • Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Amber—The server is in standby power mode. Power is supplied only to the CIMC • and some motherboard functions. Green—The server is in main power mode. Power is supplied to all server • components. Cisco UCS C24 Server Installation and Service Guide OL-26647-01z...
Green, blinking—Traffic is present on the active link. • 10/100/1000 Ethernet dedicated Off—link speed is 10 Mbps. • management link speed Amber—link speed is 100 Mbps. • Green—link speed is 1 Gbps. • Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 45
Green—Link is active. • Green, blinking—Traffic is present on the active link. • Identification Off—The Identification LED is not in use. • Blue—The Identification LED is activated. • Cisco UCS C24 Server Installation and Service Guide OL-26647-01z...
Emergency shutdown—Press and hold the Power button for 4 seconds to force the main power off • and immediately enter standby mode. Disconnect the power cords from the power supplies in your server to completely power off the server. Step 3 Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Tighten the two captive thumbscrews that secure the rear edge of the cover to the chassis. Figure 3-3 Removing the Top Cover or Front Chassis Panel Front chassis panel Top cover Front chassis panel securing screws (three) Top cover thumbscrews (two) Cisco UCS C24 Server Installation and Service Guide OL-26647-01z...
Replace the three screws that secure the panel to the chassis (see Figure 3-3). Replace the top cover to the server as described in Removing and Replacing the Server Top Cover, page 3-7. Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
PCIe riser 1 (two full-height slots) Serial Number Location The serial number for the server is printed on a label on the top of the server, near the front. Cisco UCS C24 Server Installation and Service Guide OL-26647-01z...
(An exception is the drive trays on the front panel, which are hot-swappable but not green). Some replaceable but non-hot-swappable components have light-blue plastic touch-points. • Cisco UCS C24 Server Installation and Service Guide 3-10 OL-26647-01...
The server is orderable in two different versions, each with one of two different front panel/backplane configurations: Cisco UCS C24 (small form-factor (SFF) drives, with 24-drive backplane and expander). • Holds up to twenty-four 2.5-inch hard drives or solid state drives.
Push the tray into the slot until it touches the backplane, then close the ejector lever to lock the drive in place. Figure 3-7 Replacing Hard Drives Release button Drive tray securing screws (4) Ejector lever – Cisco UCS C24 Server Installation and Service Guide 3-13 OL-26647-01z...
Install the two screws that secure the backplane assembly to the chassis floor. Step 10 Reconnect all cables to the SAS expander. Step 11 Reconnect all cables to the backplane. Step 12 Cisco UCS C24 Server Installation and Service Guide 3-14 OL-26647-01...
Page 55
Port 1 SYS FAN3 PCIe riser 2 CPU 2 SYS FAN4 Port 0 PSU 1 (bottom) PSU 2 (top) 1 Backplane assembly securing screws (two) 2 SAS expander securing screws (three) Cisco UCS C24 Server Installation and Service Guide 3-15 OL-26647-01z...
Install the three screws that secure the SAS expander to the backplane assembly steel tray (see Figure 3-9). Reconnect SAS cables to the new SAS expander. Step 5 Replace the front chassis panel. Step 6 Replace the top cover. Step 7 Cisco UCS C24 Server Installation and Service Guide 3-16 OL-26647-01...
Page 57
CPU 1 SYS FAN2 Port 1 SYS FAN3 PCIe riser 2 CPU 2 SYS FAN4 Port 0 PSU 1 (bottom) PSU 2 (top) 1 SAS expander securing screws (three) – Cisco UCS C24 Server Installation and Service Guide 3-17 OL-26647-01z...
The arrow on the top of the fan module should point toward the rear of server. Note Press down gently on the fan module until the finger-latches click and lock in place. Replace the top cover. Replace the server in the rack. Cisco UCS C24 Server Installation and Service Guide 3-18 OL-26647-01...
Page 59
Port 0 PSU 1 (bottom) PSU 2 (top) Fan tray connector (one on each fan module) 3 Connector on underside of fan module Finger latches (two on each fan module) Cisco UCS C24 Server Installation and Service Guide 3-19 OL-26647-01z...
DIMMs and their sockets are fragile and must be handled with care to avoid damage during installation. Caution Cisco does not support 3rd-party DIMMs. Using non-Cisco DIMMs in the server might result in system Caution problems or damage to the motherboard.
Page 61
Fill black slots in the channels second: A2, D2, B2, E2, C2, F2 – Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized. In a • single-CPU configuration, populate the channels for CPU1 only. Cisco UCS C24 Server Installation and Service Guide 3-21 OL-26647-01z...
Page 62
Performance Mode–Prioritizes performance memory operation. If you mix low-voltage DIMMs • with standard DIMMs, the system defaults to this setting. Press F10 to save your changes and exit the setup utility. Step 5 Cisco UCS C24 Server Installation and Service Guide 3-22 OL-26647-01...
Remove the plastic air baffle that covers the DIMM slots and CPUs. Open the ejector levers at both ends of the DIMM slot, then lift the DIMM out of the slot. Install a new DIMM: Step 2 Cisco UCS C24 Server Installation and Service Guide 3-23 OL-26647-01z...
Page 64
Replace PCIe riser 1 to it slot. See Replacing a PCIe Riser, page 3-33. Replace the top cover. Replace the server in the rack, replace cables, and then power on the server by pressing the Power button. Cisco UCS C24 Server Installation and Service Guide 3-24 OL-26647-01...
Additional CPU-Related Parts To Order With RMA Replacement Motherboards When a return material authorization (RMA) of the motherboard or CPU is done on a Cisco UCS C-series server, there are additional parts that might not be included with the CPU or motherboard spare bill of materials (BOM).
Caution between the motherboard and the CPU. Do not attempt this procedure without the required tools, which are included with each CPU option kit. If you do not have the tool, you can order a spare (Cisco PID UCS-CPU-EN-PNP). To install or replace a CPU heatsink and CPU, follow these steps:...
Page 67
Use the tool as shown in Figure 3-14 to grasp the protective cap and then pivot to remove the cap. Figure 3-14 Protective Cap Removal Tool Cisco UCS C24 Server Installation and Service Guide 3-27 OL-26647-01z...
Page 68
Make sure that the tabs on the tool are fully seated in the slots on the pedestal. Press the top button on the tool to grasp and lock in the CPU. Lift the tool and CPU straight up off the pedestal. Cisco UCS C24 Server Installation and Service Guide 3-28 OL-26647-01...
Page 69
Apply an alcohol-based cleaning solution to the old thermal pad and let it soak for a least 15 seconds. Wipe all of the old thermal pad off the old heatsink using a soft cloth that will not scratch the heatsink surface. Cisco UCS C24 Server Installation and Service Guide 3-29 OL-26647-01z...
Page 70
Alternate tightening each screw evenly to avoid damaging the heatsink or CPU. Note Replace the top cover. Replace the server in the rack, replace cables, and then power on the server by pressing the Power button. Cisco UCS C24 Server Installation and Service Guide 3-30 OL-26647-01...
If you removed PCIe riser 1, replace it to its slot. See Replacing a PCIe Riser, page 3-33. Replace the top cover. Replace the server in the rack, replace cables, and power on the server by pressing the Power button. Cisco UCS C24 Server Installation and Service Guide 3-31 OL-26647-01z...
Page 72
PCIe riser 1 CPU 1 SYS FAN2 Port 1 SYS FAN3 PCIe riser 2 CPU 2 SYS FAN4 Port 0 PSU 1 (bottom) PSU 2 (top) RTC battery holder on motherboard – Cisco UCS C24 Server Installation and Service Guide 3-32 OL-26647-01...
If you removed a card from the old PCIe riser, install the card to the new riser (see Replacing a PCIe Card, page 3-35). Position the PCIe riser over its socket on the motherboard and over its alignment points in the chassis (see Figure 3-20). Cisco UCS C24 Server Installation and Service Guide 3-33 OL-26647-01z...
Page 74
PCIe riser 2 CPU 2 SYS FAN4 Port 0 PSU 1 (bottom) PSU 2 (top) PCIe riser 1 alignment point locations (three) 2 PCIe riser 2 alignment point locations (two) Cisco UCS C24 Server Installation and Service Guide 3-34 OL-26647-01...
Installing or Replacing Server Components Replacing a PCIe Card Cisco supports all PCIe cards qualified and sold by Cisco. PCIe cards not qualified or sold by Cisco are Caution the responsibility of the customer. Although Cisco will always stand behind and support the C-Series rack-mount servers, customers using standard, off-the-shelf, third-party cards must go to the third-party card vendor for support if any issue with that particular third-party card occurs.
4. Slot 1 can operate when the server is in standby power mode. Replacing a PCIe Card Note If you are installing a Cisco UCS Virtual Interface Card, there are prerequisite considerations. See Special Considerations for Cisco UCS Virtual Interface Cards, page 3-38.
Page 77
Replace the server in the rack, replace cables, and then power on the server by pressing the Power button. If you replaced a RAID controller card, continue with Restoring RAID Configuration After Replacing a RAID Controller, page C-21. Cisco UCS C24 Server Installation and Service Guide 3-37 OL-26647-01z...
2. See note below. 3. The Cisco UCS VIC1225T is not supported for UCS integration at this time. Cisco UCS VIC P81E is not supported in the following server versions: C24 LFF (12-drive) or Note C24 16HDD (16-drive direct-connect backplane).
Page 79
ROMs for the onboard NICs to be booted from are enabled in the BIOS Setup Utility. Disable other option ROMs that are not needed to create sufficient memory space for the onboard NICs. Cisco UCS C24 Server Installation and Service Guide 3-39...
Page 80
Physically remove any unused PCIe cards. If the system has one or more Cisco virtual interface cards (VICs) installed, disable the PXE boot on the VICs that are not required for the system boot configuration by using the Network Adapters page in the CIMC WebUI to free up some 16-bit I/O resources.
Use a screwdriver to tighten the captive thumbscrew that secures the cage to the chassis floor. – Reconnect the cable from the RAID controller to the new SCPM. Replace the top cover. Cisco UCS C24 Server Installation and Service Guide 3-41 OL-26647-01z...
Page 82
Captive thumbscrew on SCPM cage SCPM holders with SCPMs installed (up to two) SuperCap power module (SCPM) SCPM cage removed from server SCPM holder SCPM cage with holders and SCPMs installed (up to two) Cisco UCS C24 Server Installation and Service Guide 3-42 OL-26647-01...
Enabling a Pre-Loaded Cisco USB Flash Drive Virtual Drive Each of the VDs on the pre-loaded Cisco USB flash drive can be separately enabled or hidden from the host. The default as shipped from the factory is for all VDs to be hidden.
Page 84
Booting a Pre-Loaded Cisco USB Flash Drive Virtual Drive When you want to access the Cisco SCU or Cisco HUU software, you boot its VD with a one-time boot option. When you want to boot the hypervisor (HV) VD, you boot it with a permanent boot order selection.
Monitoring and Managing a Cisco USB Flash Drive You can monitor and manage your installed Cisco USB Flash Drive by using the CIMC GUI interface or the CLI interface. See the Cisco UCS C-Series Rack-Mount Server Configuration Guide or the Cisco UCS C-Series Rack-Mount Server CLI Configuration Guide in the documentation roadmap linked below.
Scroll to USB Port: Internal, press Enter, and then select either Enabled or Disabled from the pop-up Step 5 menu. Press F10 to save and exit the utility. Step 6 Cisco UCS C24 Server Installation and Service Guide 3-46 OL-26647-01...
On the BIOS Setup utility screen, select the Advanced tab. Select Trusted Computing to open the TPM Security Device Configuration screen. Change TPM SUPPORT to Enabled. Press F10 to save your settings and reboot the server. Cisco UCS C24 Server Installation and Service Guide 3-47 OL-26647-01z...
Likewise, Intel TXT provides for a sealed portion of storage where sensitive data such as encryption keys can be kept, helping to shield them from being compromised during an attack by malicious code. To enable the TXT feature, follow these steps: Cisco UCS C24 Server Installation and Service Guide 3-48 OL-26647-01...
Page 89
Watch during bootup for the F2 prompt, and then press F2 to enter BIOS setup. Select the Advanced tab. Select Intel TXT(LT-SX) Configuration and verify that TXT Support, VT-d Support, and VT Support are Enabled. Cisco UCS C24 Server Installation and Service Guide 3-49 OL-26647-01z...
Printed circuit board on module Motherboard header Retention feature on module Retention feature in installed position For more information about using the module and embedded RAID, see Embedded MegaRAID Controller, page C-5. Cisco UCS C24 Server Installation and Service Guide 3-50 OL-26647-01...
Printed circuit board on module Motherboard header Retention feature on motherboard header Retention feature in installed position For more information about using the module and embedded RAID, see Embedded MegaRAID Controller, page C-5. Cisco UCS C24 Server Installation and Service Guide 3-51 OL-26647-01z...
If you shut down the server, press the Power button to return the server to main power mode. Figure 3-27 Removing and Replacing Power Supplies PCIe 4 PCIe 3 PCIe 1 PSU 2 PCIe 5 PCIe 2 PSU 1 Power supply handle Power supply release lever Cisco UCS C24 Server Installation and Service Guide 3-52 OL-26647-01...
3.4 in. (8.76 cm) Width (including slam-latches) 16.9 in. (43.00 cm) Depth 26.0 in. (66.05 cm) Weight (fully loaded) Small Form Factor: 47.2 lbs. (21.4 Kg) Large Form Factor: 53.2 lbs. (24.1 Kg) Cisco UCS C24 Server Installation and Service Guide OL-22326-01...
The power specifications for the two power supply options are listed in the following sections: 450W Power Supply, page A-2 • 650W Power Supply, page A-3 • You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/ 450W Power Supply Table A-2 lists the specifications for each 450W power supply (Cisco part number UCSC-PSU-450W).
Appendix A Server Specifications Environmental Specifications 650W Power Supply Table A-3 lists the specifications for each 650W power supply (Cisco part number UCSC-PSU-650W). Table A-3 Power Supply Specifications Description Specification AC input voltage range 90 to 264 VAC self-ranging Low range: 100 VAC to 120 VAC nominal...
Page 96
Appendix A Server Specifications Environmental Specifications Cisco UCS C24 Server Installation and Service Guide OL-22326-01...
Power Cord, 250 VAC 10 A M 2511 Plug Europe SFS-250V-10A-ID Figure B-5 Power Cord, 250 VAC 16A EL-208 Plug South Africa, United Arab Emirates, India SFS-250V-10A-IS Figure B-6 Power Cord, 250 VAC 10 A SI32 Plug Israel Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Cabinet Jumper Power Cord, 250 VAC 10 A, C13-C14 Connectors CAB-C13-C14-2M Figure B-14 Cabinet Jumper Power Cord, 250 VAC 10 A, C13-C14 Connectors CAB-C13-C14-AC Figure B-15 Cabinet Jumper Power Cord, 250 VAC 10 A, C13-C14 Connectors Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Cordset rating: 10 A, 250 V/500V Length: 2500mm Connector: Plug: EL 701C EL 206 (IEC 60320/C15) A.S. 3112-2000) Figure B-3 SFS-250V-10A-CN Cordset rating 10A, 250V Plug: (2500 mm) EL 218 (CCEE GB2009) Connector: EL 701 (IEC60320/C13) Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 100
Figure B-5 SFS-250V-10A-ID Cordset rating 16A, 250V Plug: (2500mm) EL 208 Connector: EL 701 Figure B-6 SFS-250V-10A-IS Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 101
MP232-R Connector: IEC 60320 C15 Figure B-9 CAB-9K10A-UK Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C Plug: EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 102
Figure B-11 CAB-N5K6A-NA Cordset rating: 10 A, 250 V Length: 8.2 ft Plug: NEMA 6-15P Connector: IEC60320/C13 Figure B-12 CAB-9K12A-NA Cordset rating 13A, 125V (8.2 feet) (2.5m) Plug: Connector: IEC60320/C15 NEMA 5-15P Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 103
CAB-C13-C14-2M, Jumper Power Cord (2 m) Cordset rating 10A, 250V (2.0 m) Connector: Plug: HS10S SS10A Figure B-15 CAB-C13-C14-AC, Jumper Power Cord (3 m) Cordset rating 10A, 250V (3.0 m) Connector: Plug: HS10S SS10A Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 104
Appendix B Power Cord Specifications Supported Power Cords and Plugs Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
SuperCap Power Modules (RAID Backup Units), page C-3 • • Embedded MegaRAID Controller, page C-5 • RAID Controller Cabling, page C-17 • Restoring RAID Configuration After Replacing a RAID Controller, page C-21 For More Information, page C-21 • Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Page 106
The cables in this section apply to both single- and dual-CPU configurations. Note Table C-1 lists the RAID options for the small form factor (SFF) versions of the server. Table C-1 Cisco UCS C24 Small Form Factor RAID Options SuperCap RAID Power Levels...
RAID Controller Considerations Mixing Drive Types in RAID Groups Table C-2 lists the RAID options for the large form factor (LFF) version of the server. Table C-2 Cisco UCS C24 Large Form Factor RAID Options SuperCap Maximum Power RAID Levels...
Disable SCU storage support in BIOS. Install card. Install cables. HW RAID Not applicable Not allowed Onboard SCU Storage support is Disabled in BIOS Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Enabling the Integrated RAID Controller in the BIOS, page C-8 • Disabling the Integrated RAID Controller in the BIOS, page C-8 • Launching the LSI Embedded RAID Configuration Utility, page C-9 • Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
For example, you cannot configure a three-drive array into RAID 0 and RAID 5 VDs. Unlike RAID 0, 1, and 5, you cannot create multiple RAID 10 VDs from the same array. A single RAID 10 VD uses up the entire array. Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
Note The Cisco PID UCSC-RAID-ROM5= includes the SCU upgrade ROM module. The Cisco PID UCSC-RAID-ROM55= includes the SCU upgrade ROM module and the RAID 5 key. To install a SCU upgrade ROM jumper, follow these steps: Locate the SCU_ROM header (see Figure C-1).
Step 1 Select the Advanced tab, then South Bridge. Step 2 Set Onboard SATA Controller to Disabled. Step 3 Step 4 Press F10 to save your changes and exit the utility. Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
This section contains the following topics: Downloading the LSI MegaSR Drivers, page C-10 • • Microsoft Windows Driver Installation, page C-10 • Linux Driver Installation, page C-12 Cisco UCS C24 Server Installation and Service Guide OL-26647-01...
See the following URL: http://www.cisco.com/cisco/software/navigator.html Click Unified Computing and Servers in the middle column. Click Cisco UCS C-Series Rack-Mount Standalone Server Software in the right-hand column. Click your model of server in the right-hand column. Click Unified Computing System (UCS) Drivers.
Page 115
Properties. On the Driver tab, click Update Driver to open the Update Device Driver wizard, and then follow the Step 4 wizard instructions to update the driver. Cisco UCS C24 Server Installation and Service Guide C-11 OL-26647-01...
MegaRAID stack. Note The LSI MegaSR drivers that Cisco provides for Red Hat Linux and SUSE Linux are for the original GA versions of those distributions. The drivers do not support updates to those OS kernels. Preparing Physical Installation Diskettes For Linux This section describes how to prepare physical Linux installation diskettes from the driver image files, using either the Windows operating system or the Linux operating system.
Page 117
Under Red Hat Linux and SuSE Linux, you can use a driver diskette utility to create disk images from image files. Perform the following steps to create the driver update disk: Download the Cisco UCS C-Series drivers ISO, as described in Downloading the LSI MegaSR Drivers,...
Page 118
Diskettes For Linux, page C-12. Then return to Step 4 of this procedure. To install from a virtual floppy disk: Download and save the Cisco UCS C-Series drivers ISO, as • described in Downloading the LSI MegaSR Drivers, page C-10.
Page 119
Then return to Step 4 of this procedure. • To install from a virtual floppy disk: Download and save the Cisco UCS C-Series drivers ISO, as described in Downloading the LSI MegaSR Drivers, page C-10. Then continue with the next step.
Page 120
The following message appears: LSI Soft RAID Driver Updates added. Step 15 At the menu, select the driver update medium and press the Back button. Step 16 Continue and complete the installation process by following the prompts. Cisco UCS C24 Server Installation and Service Guide C-16 OL-26647-01...
RAID Controller Cabling RAID Controller Cabling This section includes the following topics: Cable Routing, page C-17 • Cisco UCS C24 Server RAID Cabling Instructions, page C-18 • Cable Routing The RAID controller connectors in this server are shown in Figure C-2.
The server is orderable in three different versions, each with one of three different front panel/backplane configurations: Cisco UCS C24 (small form-factor (SFF) drives, with 24-drive backplane and expander). • Holds up to twenty-four 2.5-inch hard drives or solid state drives.
Connect mini-SAS cable 2 from the card connector SAS2 to the drives 5–8 connectors on the backplane. Step 4 Connect the cable 2 SGPIO connector labeled, “S2” to its backplane connector. Cisco UCS C24 Server Installation and Service Guide C-19 OL-26647-01...
Connect mini-SAS cable 1 from connector SAS1 on the card to the SAS1 connector on the expander. Step 1 Connect mini-SAS cable 2 from connector SAS2 on the card to the SAS2 connector on the expander. Step 2 Cisco UCS C24 Server Installation and Service Guide C-20 OL-26647-01...
For more information about using the Embedded MegaRAID software to configure your disk arrays, see LSI Embedded MegaRAID Software User Guide. Full LSI documentation is also available: LSI MegaRAID SAS Software User’s Guide (for LSI MegaRAID) • Cisco UCS C24 Server Installation and Service Guide C-21 OL-26647-01...
Page 126
Appendix C RAID Controller Considerations For More Information http://www.cisco.com/en/US/docs/unified_computing/ucs/3rd-party/lsi/mrsas/userguide/LSI_MR_SAS_SW_UG.pdf Cisco UCS C24 Server Installation and Service Guide C-22 OL-26647-01...
The Cisco UCS integration instructions have been moved to the integration guides found here: Cisco UCS C-Series Server Integration with UCS Manager Guides Refer to the guide that is for the version of Cisco UCS Manager that you are using. Cisco UCS C24 Server Installation and Service Guide...