Turn off the electrical power supply and close the manual gas shutoff valve 
and the manual water control valve before servicing. 
WARNING 
• Clean the cold‐water inlet filter. (Refer to diagram below) 
• Be sure that all openings for combustion and ventilation air are not blocked. 
• The venting system should be checked annually for any leaks, corrosion, blockages or damage. 
• The burner should be checked annually for dust, lint, grease or dirt. 
• Keep  the  area  around  the  water  heater  clear.  Remove  any  combustible  materials,  gasoline  or  any 
flammable vapors and liquids. 
• In accordance with all local codes and common safety practices, Water discharged from the pressure 
relief vale can cause severe burns instantly from scalding.  DO NOT touch the pressure relief valve. 
• If the relief valve discharges periodically, it may be due to thermal expansion in a closed water supply 
system. Contact the water supplier or local plumbing inspector on how to correct this situation. 
• Visual check of burner flames (see below) through the burner window in the burner assembly located 
at the middle of the water heater. 
 
 
 
 
Blue flame 
 
 
Satisfactory 
The manufacturer recommends having the unit checked once a year or as necessary by a licensed 
technician. If repairs are needed, any repairs should be done by a licensed technician. 
 
UNIT DRAINING and FILTER CLEANING
 
1. Close the manual gas shut off valve. 
2. Turn  off  power  to  the  unit  and  wait  a  couple  of 
seconds. Turn on again. 
3. Wait 30 seconds, and then turn off power to the unit, 
yet again. 
4. Close the water shut off valve. 
5. Open  all  hot  water  taps  in  the  house.  When  the 
residual  water  flow  has  ceased,  close  all  hot  water 
taps. 
6. Have  a  bucket  or  pan  to  catch  the  water  from  the 
unit's drain plugs. Unscrew the two drain plugs (Large 
and small) to drain all the water out of the unit.  
7. Wait  a  few  minutes  to  ensure  all  water  has 
completely drained from unit. 
8. Clean the filter: Check the water filter located within 
the cold inlet. With a tiny brush, clean the water filter 
of  any  debris  which  may  have  accumulated  and 
reinsert the filter back into the cold water inlet. 
9. Securely screw the drain plugs back into place. Hand‐ 
tighten only. 
MAINTENANCE AND SERVICE 
Flame 
blowing up 
Unsatisfactory 
36
Red or Yellow 
flame 
Drain Plug 
with Filter 
(Large) 
Drain Plug 
(Small) 
 
Page
 Normal Operation 
Unsatisfactory 
 
Gas Valve 
Water Valve 