Table 4.22 Mode Select Parameters: Control Mode Parameters - Fujitsu MAU3147RC SERIES Technical Manual

Serial attached scsi interface specifications
Hide thumbs Also See for MAU3147RC SERIES:
Table of Contents

Advertisement

(7) Control mode parameters (page code = 0A)
The page descriptor format of this MODE SELECT parameter is shown in Table
4.22.

Table 4.22 MODE SELECT parameters: control mode parameters

Bit
Byte
0
1
2
Default
Variable
3
Default
Variable
4
Default
Variable
5
6-7
Default
Variable
8-9
Default
Variable
10-11
Default
Variable
The parameters defined on this page control the operations of the tagged queuing
function and statistical information function.
C141-C009
7
6
5
0
0
0
TST
0
0
0
0
0
0
Queue Algorithm Qualifier
0
0
0
1
1
1
Reserve
RAC
Reserved
d
0
0
0
0
0
0
Ready Aer Holdoff Period
Extended Self-Test Completion Time
4.1 Control/Sense Commands
4
3
2
0
1
0
X'0A' (Page Length)
(Reserved)
0
0
0
0
0
0
Reserved
0
0
0
1
0
0
SWP
RAERP UAAER
0
0
0
0
0
0
X'00' (Reserved)
X'0000'
X'0000'
Busy Timeout Period
X'0000'
X'0000'
X'xxxx'
X'0000'
1
0
1
0
GLTSD
RLEC
0
0
1
1
Qerr
DQue
0
0
0
0
EAERP
P
0
0
0
0
4-51

Advertisement

Table of Contents
loading