7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
To Convert Grill Burner (on some models)
1. Remove grill grate, wave plate, flame spreader and burner
assembly. See "Install Grill Grease Trays" section for removal
instructions. Set parts aside.
2. Use a ½" deep-well socket to remove the Natural gas orifice
hood. Replace with correct grill LP gas orifice hood. See "LP
Gas Orifice Spud/Hood Chart."
A
A. Grill orifice hood location
3. Turn LP gas orifice hood down tightly onto orifice base.
4. Place Natural gas orifice hoods in plastic parts bag for future
use and keep with package containing literature.
5. Before replacing the burner assembly, loosen the screw at the
front of the burner and rotate the shutter so that the opening
is
" (8.0 mm) wide.
A. Shutter opening
B. Screw
6. Reinstall the burner assembly, flame spreader, wave plate,
and grill grate. See "Install Grill Grease Trays" section for
installation instructions.
7. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
REMEMBER: Once you have completed converting the grill,
test the range for leaks by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show,
indicating a leak. Correct any leaks found.
8. Plug in range or reconnect power.
Complete Installation
1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Refer to the "Electronic Ignition System" section for proper
burner ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
¼" (0.64 cm) to ½" (1.3 cm) long. The outer cone is not as
distinct as the inner cone. LP gas flames have a slightly
yellow tip.
3. Refer to "Complete Installation" in the "Installation
Instructions" section of this manual to complete this
procedure.
A
B

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position. Turn over the spring retainer
so the "NAT" is showing on the bottom. Snap the spring
retainer back into the cap. Reinstall the cap onto the regulator.
E
D
A. Access cap
B. Gasket
C. Gas pressure regulator
B
C
A
B
C
D. NAT position
E. LP position