Page 1
Portable Air Conditioner PAC701W Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
Important Safety Information Improper handling can cause serious damage to the appliance and/or to the user. Please read the following safety information. Electrical Safety This unit is designed for indoor use only. Do not use the unit in extremely humid or wet environments. ...
................... 14 LEANING THE UNIT ................. 14 LEANING THE PRE FILTER ................14 REPARATION FOR TORAGE TROUBLESHOOTING ..................15 ................. 17 ROUBLESHOOTING CONTINUED SPECIFICATIONS ....................18 EDGESTAR LIMITED WARRANTY ..............19 Koldfront Portable Air Conditioner...
Introduction Thank you for purchasing this Koldfront portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
2. Air Vent 3. Handle 4. Pre-Filter 5. Air Intake 6. Water Outlet Drain 7. Castors (4) 8. Continuous Drain Water Outlet (for dehumidify mode only) 9. Air Outlet (Heat Exhaust) 10. Power Cord Back View Koldfront Portable Air Conditioner...
Window Kit Installation Instructions You must vent your portable air conditioner when running in it Preparations for installing cooling mode. Your unit includes a window exhaust kit that can be the window kit used to vent the unit out a window. Before you begin, make sure you have all the parts necessary for installation.
1. Insert the round grated adapter through the back grooved side of the window kit plate with hole. 2. Secure the grated adapter by fastening the screws from flat side of the window kit plate to the holes on the grated adapter. Koldfront Portable Air Conditioner...
Installing the window plates 3. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. CAUTION: Secure your window by using window locks.
A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops. 6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall. Koldfront Portable Air Conditioner...
Connecting the duct connector to the unit 7. Align the slots on the duct connector to the tabs and snap into the back of the unit. Connecting the duct connector to the grated adapter 8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place.
2. Connect a drain hose to the drain port. The portable air conditioner will now drain through the drain hose. Please note that this unit has no drain pump; all water will drain with gravity only, i.e., only “downhill.” Koldfront Portable Air Conditioner...
Control Panel Overview LED Display Fan Speed Button Remote Sensor Warning Light Timer Button Mode Lights Timer/Temperature Set Buttons Power Button Mode Button Fan Speed Lights Function The LED can display the ambient LED Display temperature, set temperature, and the number of hours when setting the timer.
Once the water is manually drained, the unit will operate normally. The remote control sensor receives infrared signals given by the Remote Control Sensor remote control. Koldfront Portable Air Conditioner...
Remote Control Overview The remote control is used to operate all of your portable air conditioner’s functions. Power On/Off Mode Fan Speed + Increase Timer - Decrease NOTE: Be careful not drop the Button Function remote control. Do not place Power Powers the unit on or off.
Additionally, the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose. You will be not be able to change the thermostat temperature or fan speed while in Dehumidifying Mode. Koldfront Portable Air Conditioner...
Operating the Remote continued Fan Only mode is used to circulate the air in your room. No Fan Only Mode temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the Power button on the remote.
2) Power off the unit, and clean or change the filters. 3) Unplug and carefully wind the power cord. 4) Remove the exhaust hose and duct connectors and keep them in a safe place. Koldfront Portable Air Conditioner...
Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner: Do not cover the air outlet (exhaust) while in use. Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake.
Unit may have a faulty Contact customer lights blink randomly. control panel. service. No air comes out the The unit is designed to This is normal left side of the air vent. blow air from the right. operation. Koldfront Portable Air Conditioner...
Troubleshooting continued Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all. cooling mode. cooling mode, and lower the set temperature (pg. 13). The compressor is not The compressor may take up to 3 minutes to turn on, or longer if it is...
PAC701W Voltage/Frequency AC 115V~60Hz Input Power 650W Current 6.0A Color White Dehumidifying capacity 61 Pints/Day Coolant R-410A Timer 24 Hour Dimensions 17 13/16” x 26 1/4” x13 5/16” W x H x D Weight 48.5 lbs Koldfront Portable Air Conditioner...
EdgeStar Limited Warranty One (1) Year Parts & Ninety (90) Days Labor This product is warranted by EdgeStar to be free from defective workmanship and materials, subject to any conditions set forth as follows: WHAT IS COVERED: LABOR: For a period of NINETY (90) DAYS from the date of original purchase, labor will be performed free of charge at an authorized EdgeStar repair facility.
Need help?
Do you have a question about the PAC701W and is the answer not in the manual?
Questions and answers