I
CARE OF YOUR HOME DRINKING
WATER SYSTEM
t
PREFILTER
CARTRIDGE
- You must replace
the prefilter cartridge often to protect the RO mem-
brane from being destroyed by chlorine, and/or from
plugging with sediments from the water supply. If
you have chlodne in the water, replace the cadddge
at least every 6 months. If the prefilter cartridge
plugs with sediments, water flow into the RO system
drops, slowing the making of quality RO water. The
RO membrane
may also begin
to plug with
sediments. If this happens, you may not get enough
RO water for your needs.
NOTE: The amber "FILT" light on the faucet base
will begin to flash after 6 months or 900 gallons of
product water use to tell you the filter cadridge
needs replacing:.
. ,
postfllt_
BOTTOM
END
POSTFILTER.
Always replace the postfilterat the
same time you replace the prefilter cartridge. The
postfilter gives the product water a final filtering of
any tastes and/or odors that may remain.
TO REPLACE
THE POSTFILTER
CAUTION: BE SURE TO REUEVE PRESSURE,
STEPS 1, 2 AND 3, Bo'n'OM OF PAGE 12.
1. Disconnect tubing at both ends (Fig. 9).
2. Pull the filter from the holder and remove fittings
from both ends.
3. Observing the flow arrow, on new filter, turn the
fittings (use Teflo n tape) into both ends. The
elbow fitting installs at the bottom end, or outlet.
4. Replace filter into the holder and reconnect the
tubing at both ends.
TO REPLACE THE PREFILTER CARTRIDGE
CAUTION: BE SURE TO REUEVE PRESSURE,
STEPS 1,2 AND 3, BOI'rOM OF PAGE 12.
IMPORTANT:
BE SURE YOUR
HANDS
ARE
CLEAN BEFORE WORKING ON RO SYSTEM IN-
TERNAL PARTS.
1. Remove the clamp retainers and clamp sections
(Fig. 9).
2. Separate the cap from the RO housing (no need
to disconnect tubing) and set aside.
NOTE: If the cap o-ring seal remained In the
RO housing, replace It on the cap.
3. Lift the RO cartddge and prefilter cartridge from
the housing, then separate and dispose of the
prefilter cartridge.
4. Dump water remaining in the RO housing.
5. Slide the RO cartddge INTO THE TOP END of
the new prefilter cartddge, as shown in FIG. 9,
then place into the RO housing.
NOTE: Be sure the bottom end of the preftlter Is
at the bottom, and the up arrow ( _ ) on the RO
cartridge points upward (o-ring seal end down-
ward).
6. Be sure the cap o-dng has lubrication (silicone
grease). Then, push into position and install
clamp sections and retainers.
7. Replace the electronic box batteries.., see page
14.
13