PEDICURE SPA USER MANUAL
Before Operating the unit, please read this manual thoroughly and retain it for future reference

RECEIVING AND INSPECTION:

PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival. It is
important that you notify the driver and insist on a notation of the damage. Make this
notation directly on the freight company's waybill or bill of lading. Failure to note damage on
the waybill or bill of lading may impede and/or prevent any claims that you may have
against the freight carrier.
If missing parts or damage is found. Please notify the carrier at once and request an
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear receipt
for goods that have been damaged in transit, you do so at your own risk and expense.
TRADEMARK DISCLAIMER
V-Spa, Elite Platinum, Mystique, Versas, Vista, Elite Ultra, Q-Spa, Sani-Drain, PureFlo, Pioneering "SMART" Pedi-Spa, Auto-Fill, AutoClean, and TT350
and Tru-Touch are the registered trademarks of Lexor, Inc. Reproduction or reuse of part or all of trademarks are expressly prohibited without written
permission from Lexor, Inc. Due to limitation of the printing process, product colors shown might look different from actual colors. Lexor will not be
responsible for any misprint of this advertisement. Lexor's footspa specification and prices may change without prior notice. Pedicure Spas are intended for
professional used only, always follow your State Board's sanitation and disinfectant guideline.
Pioneering "Smart" Pedi-Spas
 
Q-SPA
®
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q-SPA and is the answer not in the manual?

Questions and answers

Summary of Contents for Lexor Q-SPA

  • Page 1: Receiving And Inspection

    Tru-Touch are the registered trademarks of Lexor, Inc. Reproduction or reuse of part or all of trademarks are expressly prohibited without written permission from Lexor, Inc. Due to limitation of the printing process, product colors shown might look different from actual colors. Lexor will not be responsible for any misprint of this advertisement.
  • Page 2: Table Of Contents

    Table of Contents RECEIVING AND INSPECTION: ............1 SAFETY PRECAUTIONS: ................ 3 PARTS Identifying Part for Qspa Model ……………………………………………….4 INSTALLATION Spa to Spa recommended for Clearance ……………………………………….5 Wall Clearance ………………………………………………………………...…..5 Manicure Tray /Armrest/ Backrest Installation …………………...…………..6 …………. Up/Down Swinging Armrest………………………………………………………… Back rest …………………………………………………………………………………………...
  • Page 3: Safety Precautions

    If a crack in the GLASS BOWL occurs, DO NOT handle unless the proper attire and equipment is used. Discontinue use of the bowl until proper equipment is replaced. You may be held accountable for any injury that may occur. Lexor, Inc. is not liable for any injury that may occur.
  • Page 4: Identifying Part For Qspa Model

    Identifying Parts __________________________________________________________ ® Identifying Parts for Q-Spa Model Pedicure Whirlpool with Massage System 1. Head Rest Discharge On/Off Knob 13. Handbag (Purse) Hook 2. Chair Cushion with Dual Function Auto-Fill™ (Upgrade Option Only) Massage & Jet On/Off Knob 14. Tub Light 3.
  • Page 5: Installation

    Installation ________________________________________________________________ SPA to SPA RECOMMENDED CLEARANCE: Wall Clearance:...
  • Page 6: Manicure Tray /Armrest/ Backrest Installation

    Installation ________________________________________________________________ MANICURE TRAY/ ARMREST / BACK REST INSTALLATION Up/Down Swinging Armrest: 1. Plug-In the manicure trays and attach the purse hook. (1 Supplied)
  • Page 7: Back Rest

    Installation _______________________________________________________________ BACK REST: 1. To set backrest up: Lift up the backrest until a “Click” is heard. Make sure the lever is locked before operating. 2. To fold down backrest: Lift up lever handle located on the left side / bottom of Chair.
  • Page 8: Plumbing Connections

    Installation _______________________________________________________________ Plumbing Connections: Warning Before any connection, pay attention to these subjects: 1. Debris or residue may become lodged into the Hot and Cold hoses during construction, which may clog the Hot and Cold Mixer. To clean, drain a good amount of water from water hoses to bucket before connecting them to the pedicure spa.
  • Page 9: Gravity Drain

    Installation _______________________________________________________________ Gravity Drain (Under Ground): Plumbing Flow Pattern for Power Drain:...
  • Page 10: Plumbing Flow Pattern For Gravity Drain

    Installation _______________________________________________________________ Plumbing Flow Pattern for Gravity Drain: HOT AND COLD WATER SUPPLY LINES Carefully connect ½” ID supply hoses (not provided) to fresh water sources. Shut-off valves (not provided) should be utilized. Valves should be placed outside the tub for easy access. Before water line connections, please follow below: Determine if your spa chair is used for a new construction of a salon or a replacement spa chair.
  • Page 11: Connectiong Drain System

    Installation _____________________________________________________________ CONNECT DRAIN WITH POWER DRAIN (PUMP) OR GRAVITY DRAIN (NO PUMP) Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate traps. Connect drain to meet local plumbing codes. Rubber connection to the drain should be removable for easy service and should not be permanent to prevent damages.
  • Page 12: Spa Specification

    Electrical Switches One (1) electro-mechanical knob for the Drain. Rated at 5A contact. Installation should be made with connection at the external interface parts. Plug & Play Installation Please consult with your local plumber. Safety Q-Spa® Pedicure Spa is UL listed.
  • Page 13: Operation And Care

    Operation and Care _______________________________________________________ OPERATION AND CARE INSTRUCTIONS Manual Operation (For Non Auto-Fill™/Drain Models): Filling Close the Drain Stopper by turning the Drain Knob counterclockwise. Utilizing the single lever hot/cold mixer faucet located on the front of the Pedicure Spa, fill the tub to the water level above the whirlpool jet at least 1 inch.
  • Page 14: Auto Operation

    Operation and Care _______________________________________________________ Auto Operation: (Upgraded Option) Auto-Fill™ Models: Automatic Auto-Fill™ cycle: Water will automatically turn-off when optimal water level is detected by 2 sensors It is followed with the immediate start of Whirlpool jet for a duty cycle of thirty (30) minutes. The Auto-Fill™ cycle is safely protected by 2 sensors, 3-minute time out and can be extended with a manually operative shut-off valve located at the front panel.
  • Page 15 Operation and Care _______________________________________________________ Auto-Fill™ / Jet Switch: (Dual-functional momentary switch located on the right side of the front panel) 1. To turn water on: Turn knob clockwise for 1 second and release. Water will fill up to reach the sensor level and activate the whirlpool jets to proceed a running duration of thirty (30) minutes automatically.
  • Page 16: Jet Cover Removal & Installation

    Jet Cover & Impeller _______________________________________________________ JET COVER REMOVAL & INSTALLATION: 1. Turn Counterclockwise to remove. Turn Clockwise to install.
  • Page 17: Jet Housing Removal & Installation

    Jet Cover & Impeller _______________________________________________________ JET HOUSING REMOVAL & INSTALLATION 1. Turn clockwise to remove motor. Turn counterclockwise to install motor.
  • Page 18: Top Massage Chair Basic Installation

    Operation and Care ______________________________________________________________ MASSAGE SYSTEM & REMOTE CONTROLLER: 1. Press Auto Button to start Auto mode. Press again to turn off massage. Auto and Manual mode will run for duration of 20min. 2. Press any button (Rolling/Spot, Kneading, Tapping, Combine) to enter Manual mode. 3.
  • Page 19 Operation and Care _______________________________________________________ NOTE : If the Massage Chair is not provided, then the end-user will need to install a UL listed and cUL/CSA certified massage chair with a suitable Class 2 Power Supply. TOP MASSAGE CHAIR BASIC INSTALLATION INSTRUCTIONS: Fig.2 Fig.1 Install seat cushion with 2 screw-Knobs...
  • Page 20: Safety Requirements For Pedicure Spas

    WARNING ou must always refer to your state or local guidelines for cleaning requirements Overnight soaking with overdosed Chlorine may damage rubber part in basin CLEANING PROCEDURE IS REQUIRED BY STATE BOARDS Note: *** A cleaning log should be kept with each pedicure spa *** Each State will have slight differences in cleaning policies, please check with your state’s Bureau of Barbering and Cosmetology or Regulatory Authority for specific details.
  • Page 21 FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND/OR WARRANTY WILL BE NULL. YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE SAFELY. UL SAFETY RECOGNIZED FOR UNITED STATES AND CANADA. LEXOR INC.14800 GOLDENWEST ST., WESTMINSTER, CA 92683, USA CUSTOMER CARE: TEL: 1-800-559-3630 FAX: 1-714-622-1740 www.lexor.com ©2012 All Rights reserved.