TANDBERG Codec 3000 MXP Reference Manual
TANDBERG Codec 3000 MXP Reference Manual

TANDBERG Codec 3000 MXP Reference Manual

Guide for system integrators
Table of Contents

Advertisement

Codec
3000
6000
MXP
Designed for custom integrations
19" mountable codecs
Expandability for future applications
Total management via serial port, embedded web
server, SNMP, Telnet, XML, HTTP / HTTPS, FTP and
on screen menu
Best possible call for each MultiSite participant with
rate matching and transcoding
URI dialling
H.323, H.320 & SIP support
TANDBERG Expressway™ Technology
Protection against network interruptions in point-
to-point and multipoint calls with automatic
downspeeding and IPLR
Standards-based embedded encryption
(AES & DES)
REFERENCE
FOR SYSTEM
INTEGRATORS
Software version F7.X
D 13887.08
MAY 2008
TANDBERG 3000
MXP
& 6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Codec 3000 MXP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TANDBERG Codec 3000 MXP

  • Page 1 6000 • URI dialling • H.323, H.320 & SIP support • TANDBERG Expressway™ Technology • Protection against network interruptions in point- to-point and multipoint calls with automatic downspeeding and IPLR • Standards-based embedded encryption (AES & DES)
  • Page 2: Finding The Information You Need

    Finding the Information You Need We recommend that you check out the Thank you for choosing TANDBERG! TANDBERG web site regularly for updated The TANDBERG Codec 3000 and Codec 6000 versions of this manual: http://www.tandberg.com/support/ have been designed to provide you with many years of documentation.php...
  • Page 3: What's New In This Version

    Use this setting with caution rect mode. Try setting this value higher if you need a continuous New in this version. TANDBERG MXP systems now support since it in a normal network will decrease the video quality. The stream of data on the receiving end.
  • Page 4 New in this version. Enables/disables the given key on the New in this version. Enables/disables the signal which is sent TANDBERG Remote Control. TANDBERG Remote Control. to the codec when grabbing the TANDBERG Remote Control. Key Number8: <On/Off> Key Layout: <On/Off> Key Cabinet: <On/Off>...
  • Page 5: Command Instructions

    & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Key Help: <On/Off> New in this version. Enables/disables the given key on the TANDBERG Remote Control (TRC4). Key MainCam: <On/Off> New in this version. Enables/disables the given key on the TANDBERG Remote Control (TRC4).
  • Page 6: Table Of Contents

    European Environmental Directives ......14 Data Port (RS 232) ............42 Waste Handling ............14 Cable wiring TANDBERG MXP ↔ PC via RS 232 ..... 42 Information for Recyclers ..........14 XACLI – the Basics ............43 Digital User Guides ............ 14 Root Commands ............
  • Page 7 Integrator ..............89 GroupEntry [1..50] ............. 122 XACLI – Special Commands – xgetxml ....... 62 IP ................89 TXAS - TANDBERG XML API Service ........63 IPMedia ..............90 GlobalEntry ..............123 Bare-bone HTTP(S) Access .......... 63 IPProtocol ..............90 IRControl ..............
  • Page 8 DialGlobalEntry ............153 TextDelete ..............163 The extswitch ............227 DialGroupEntry ............153 TextDisplay ............... 163 Interfacing to the TANDBERG WAVE II Camera ....228 DialLocalEntry ............153 VirtualMonitorReset ..........164 Command and Response Exchange Sequence .... 228 DisconnectCall ............154 VirtualMonitorSet ............
  • Page 9: Intellectual Property Rights

    This Reference Guide for System Integrators and the Products to TANDBERG web site regularly for updated which it relates contain information that is proprietary to TANDBERG versions of this manual: and its licensors. Information regarding the Products is found on the http://www.tandberg.com/support/...
  • Page 10: Disclaimer

    Every effort has been made to supply complete and accurate information in this Reference Guide for System Integrators, however, TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document. INTELLECTUAL PROPERTY RIGHTS...
  • Page 11: License Information And Patent Information

    Snprintf is distributed under the terms of the snprintf license which All or some portions of this file are derived from material licensed by contacting TANDBERG. Please contact us by using the is a Frontier Artistic style open source license.
  • Page 12: Operator Safety / Environmental Issues

    Operator Safety / Environmental Issues We recommend that you check out the For your own protection, please read the overleaf safety TANDBERG web site regularly for updated instructions completely, before operating the equipment versions of this manual: and keep this manual for future reference. The information http://www.tandberg.com/support/...
  • Page 13: Safety Instructions

    – for example near a bathtub, adaptor) specified by TANDBERG (adaptor Do not operate the apparatus in areas with kitchen sink, or laundry tub, in a wet base- is supplied with 3000 only).
  • Page 14: Environmental Issues

    Produce products that can be recycled or disposed of safely in our environment and to diminish the pressure on natural CD – which can be used with all TANDBERG products – in a at the end of product life resources, we encourage you to use the appropriate take-back variety of languages.
  • Page 15: China Rohs Table

    Environmental Issues TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS China RoHS Table D 13887.08 MAY 2008...
  • Page 16: What's In The Shipping Box

    What’s in the Shipping Box? This part of the Reference Guide for System Integrators We recommend that you check out the TANDBERG web site regularly for updated presents the contents of the shipping box to ease your versions of this manual: acceptance test as well as assist you in making sure http://www.tandberg.com/support/...
  • Page 17: Contents Of The 3000 Mxp Codec Shipping Box

    4 ISDN BRI cables (depending on region) Batteries for remote control (not included with the NET version) Rack mounting kit (II) Rack mounting kit (I) Codec 3000 MXP User registration card Split cable for Power supply non-TANDBERG WAVE II cameras Video DVI–VGA cable...
  • Page 18: Contents Of The 6000 Mxp Codec Shipping Box

    What’s in the Shipping Box? Contents of the 6000 MXP Codec Shipping Box TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Up to 4 mains cables CD with user documentation Remote control (depending on region) Batteries for remote control...
  • Page 19: Interfaces And Sockets - Codec 3000 Mxp

    Interfaces and Sockets – Codec 3000 MXP This part of the manual provides an in-depth presentation We recommend that you check out the TANDBERG web site regularly for updated of the rear panel sockets and interfaces of the Codec versions of this manual: 3000 MXP, including the audio signal levels and the http://www.tandberg.com/support/...
  • Page 20: Rear Panel Socket- And Interface Groups

    Rear Panel Socket– and Interface Groups TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS The Codec 3000 MXP comes in two flavours – with ISDN BRI sockets (upper) or with Net socket (lower). Codec 3000 PC card Camera DC power socket...
  • Page 21: Audio Sockets

    Signal type Balanced Unbalanced loudspeaker system, which may, or may not, balanced, 24V phantom audio from the far end. include the TANDBERG Digital Natural Audio powered via XLR connectors. Socket XLR-F RCA/phono Module. This output should be used when connecting a...
  • Page 22: Audio Signal Levels In Vpp And Dbu

    Interfaces and Sockets – Codec 3000 Audio signal levels in Vpp and dBu TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Microphone Inputs 1 & 2 Audio Inputs 3 & 4 Audio Outputs 1 & 2 NoTe! Audio inputs 3 & 4 are referred...
  • Page 23: Video Sockets

    Analogue Vertical Hot plug detect T.M.D.S. Clock– If your DVI cable is not long Signal Sync If you are using TANDBERG supplied monitors this will give WXGA out enough, use extension cables. when displaying graphics. Analogue Red Analogue Green Analogue Blue...
  • Page 24: Camera Socket

    Wherever applicable, the use Camera Connect the camera here. Use of Category 5 cabling or better is a TANDBERG 3000 WAVE II Camera strongly recommended! For HD camera cable or similar. applications, however, Category 7.5 is To connect a non-TANDBERG camera required.
  • Page 25: Isdn Bri Sockets

    Interfaces and Sockets – Codec 3000 ISDN BRI sockets (not applicable to 3000 MXP Net) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Tip! Wherever applicable, the use of Category 5 cabling or better is strongly recommended! For HD camera applications, however, Category 7.5 is...
  • Page 26: Net Socket

    Interfaces and Sockets – Codec 3000 Net socket (applies to 3000 MXP Net only) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS RS366 DTE → DCE Signal name Direction Description ↔ Net interface socket. 1 × X.21 / V.35 / RS449...
  • Page 27: Network Interface Sockets

    Interfaces and Sockets – Codec 3000 Network Interface Sockets TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Tip! Wherever applicable, the use of Category 5 cabling or better is PC card. Wireless LAN PC card strongly recommended! For HD camera may be inserted here.
  • Page 28: Power Socket & On/Off Switch

    Interfaces and Sockets – Codec 3000 Power Socket & On/Off Switch TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CauTioN! This equipment must be earthed! Power switch Power cord socket. Accepts 12 V DC / 4.3 A D 13887.08...
  • Page 29: Interfaces And Sockets - Codec 6000 Mxp

    Interfaces and Sockets – Codec 6000 MXP This part of the manual provides an in-depth presentation We recommend that you check out the TANDBERG web site regularly for updated of the rear panel sockets and interfaces of the Codec versions of this manual: 6000 MXP, including the audio signal levels and the http://www.tandberg.com/support/...
  • Page 30: Rear Panel Socket- And Interface Groups

    Interfaces and Sockets – Codec 6000 Rear Panel Socket– and Interface Groups TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Network interface sockets Audio sockets Video sockets Power socket and On/Off switch D 13887.08 MAY 2008...
  • Page 31: Audio Sockets

    VCR to Output impedance 680 W The phantom powering the TANDBERG Digital Natural add-on system. the system. Max input level when set to of XLR socket No. 3 can Audio Module.
  • Page 32: Audio Signal Levels In Vpp And Dbu

    Interfaces and Sockets – Codec 6000 Audio Signal Levels in Vpp and dBu TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Microphone Inputs 1, 2 & 3 Microphone Input 3 Audio Inputs 4, 5 & 6 Audio Outputs 1, 2 & 3...
  • Page 33: Video Sockets

    Analogue Vertical Hot plug detect T.M.D.S. Clock– If your DVI cable is not long Signal Sync If you are using TANDBERG supplied monitors this will give WXGA out enough, use extension cables. when displaying graphics. Analogue Red Analogue Green Analogue Blue...
  • Page 34: Net Interface Socket

    Interfaces and Sockets – Codec 6000 Net Interface Socket TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS HD D-SuB 26 pin-out External view of socket Net interface socket. 1 × X.21 / V.35 / RS449 with 1 × RS366 Call Control up to 2 Mbps...
  • Page 35: Network Interface Sockets

    Interfaces and Sockets – Codec 6000 Network Interface Sockets TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Tip! Wherever applicable, the use E1/T1 Interface ISDN PRI interface. of Category 5 cabling or better is 1 × PRI (RJ-45 Jack) Primary strongly recommended! For HD camera Rate &...
  • Page 36: Camera Sockets

    Category 7.5 is required. S-video Mini-DIN pin-out External view of socket Pin 1: Ground (Luminance) 9-pin D-SuB pin-out TANDBERG WAVE II TANDBERG HD 6000 Pin 2: Ground (Chrominance) External view of socket Camera cable pin-out Camera cable pin-out...
  • Page 37: Data Ports

    From DCE Ring indicator, Ring indicator, 1) The TANDBERG main camera is normally connected to data port 2 and pin No. 4 provides 12 V / 1 A to the main camera. Otherwise the pin-outs are the same for the two data ports.
  • Page 38: Power Socket & On/Off Switch

    Interfaces and Sockets – Codec 6000 Power Socket & On/Off Switch TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CauTioN! This equipment must be earthed! Power cord socket Accepts 100–240 V 50–60 Hz 1 A max. Power switch D 13887.08...
  • Page 39: About The Tandberg Api

    About the TANDBERG API The heart of the API is the TANDBERG API-Engine. This is We recommend that you check out the TANDBERG web site regularly for updated where all information is stored and processed. The API- versions of this manual: engine can be accessed by an easy-to-use Command Line http://www.tandberg.com/support/...
  • Page 40: Introduction

    All information is stored in a hi- actively returns updated status and configuration information to the user/ If we now look at the TANDBERG systems we can identify three main types of erarchic tree structure which is accessible control application whenever changes occur.
  • Page 41: Dataport Interface On The Classic Systems

    Interface Supported on the Classic Systems? The TANDBERG also supports the RS 232/Telnet Da- Example showing Serial Port configurations of a TANDBERG Example: To address the BaudRate element of serial port 2: taport Interface that was supported on the Classic systems.
  • Page 42: Xacli

    From DCE Clear to send, CTS The RS 232 port is a 9-pin, female, D-sub connector located on the back of the TANDBERG MXP. The port is configured From DCE Ring indicator, RI as a DCE (Data Communications Equipment). The RS 232 port is default set to 9600 baud, 8 data bits, none parity and 1 stop bit from factory.
  • Page 43: Xacli - The Basics

    By typing after connecting to the alrtvol enable los-inhibit rnumber TANDBERG MXP using RS 232/Telnet, the ansdelay encmode los-initial screensaver system will list all supported root com- audioagc encrypt los-polarity selfview mands. audiofeature encstatus...
  • Page 44: Xacli - Main Types Of Commands

    RS 232/Telnet for which it returns the information XML formatted. IMPORTANT! This command has various is specified. If connecting to the TANDBERG settings to define the formatting of the XACLI More on this can be found in xgetxml. with multiple RS 232/Telnet sessions, output.
  • Page 45: Xacli - Configuration Type Commands

    About the TANDBERG API XACLI – Configuration Type Commands TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE: About Configuration Type Commands xconfiguration ? All Configurations are organized in a hierarchic tree structure. - User Configurations - To get an overview of accessible top-level configuration elements within a...
  • Page 46: Xacli - Configuration Type Operation

    About the TANDBERG API XACLI – Configuration Type Operation TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS About Configuration Operations Configuration Help Configuration Read Three operations can be performed on To get help on configurations, type after the configuration path...
  • Page 47: Xacli - Configuration Types

    About the TANDBERG API XACLI – Configuration Types TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS About Configuration Types Format for Value Types Integer values: <x..y> The system supports the following value Defines the valid range for an integer input. x = min value, y = max value.
  • Page 48: Xacli - Command-Type - Xcommands/Xdirectory

    About the TANDBERG API XACLI – Command-type Commands – xcommands/xdirectory TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Getting an Overview Example Showing How to Get an Overview of Supported Commands To get an overview of the supported command-type commands, type ? or help after the com- mand-type command (xcommand) .
  • Page 49: Xacli - Command-Type - Issuing A Command

    If there are multiple instances of a parameter, the item number is added after the tag separated with a dot: LogTag: 6 *r/end <command-type command> <command> <parameter.item:value> <parameter.item:value>... EXAMPLE: If complete path is enabled for the RS-232/Telnet session xcommand groupentryadd name:TANDBERG localentryid.1:15 localentryid.2:57 (“xpreferences completepath on”): EXAMPLE xcom dial 558458 *r Result (status=OK): *r Result CallRef: 1...
  • Page 50: Xacli - Command-Type - Parameter Value Types

    About the TANDBERG API XACLI – Command-type Commands – Parameter Value Types TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Parameter Value Types Format for Value Types The system supports the following value types: Integer values:<x..y> • Defines the valid range for an integer input. x = min value, y = max value.
  • Page 51: Xacli - Status Type Commands

    About the TANDBERG API XACLI – Status Type Commands TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE About Status Type Commands Defining Element names, Values, Attributes, and Item No.: xstatus call 1 Call (status=Synced, type=Vtlph, protocol=H323, direction=Outgoing, logTag=1):...
  • Page 52: Xacli - Status Type - Default Formatting

    About the TANDBERG API XACLI – Status Type Commands – Default Formatting TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE showing status for a disconnected call. About Status Type Commands Formatting xstatus call 1 *s Call 1 (status=Disconnected, type=NA, protocol=NA, direction=NA, logTag=NA):...
  • Page 53: Xacli - Status Type - Complete Path Formatting

    About the TANDBERG API XACLI – Status Type Commands – Complete Path Formatting TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE About Status Type Commands Formatting xpreferences completepath on XACLI supports three different formattings for status information: xstatus call 1 •...
  • Page 54: Xacli - Status Type - Xml Formatting

    About the TANDBERG API XACLI – Status Type Commands – XML Formatting TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE About Status Type Commands Formatting xgetxml status/call[1] <Status> <Call item=”1” status=”Synced” type=”Vtlph” protocol=”H323” direction=”Outgoing” logTag=”2”> XACLI supports three different formattings for status <CallRate item=”1”>768</CallRate>...
  • Page 55: Xacli - Status Type - Addressing Status Information

    About the TANDBERG API XACLI – Status Type Commands – Addressing Status Information TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE 1 a) Addressing status information, user wants to know callrate of call 1: About Addressing Status Information...
  • Page 56: Xacli - Status Type - Exposure Options

    Exposure options should be used to limit the amount of information returned. By adding an CallRate: 768 exposure option after the address expression (XPath or TANDBERG SimplePath), the system RemoteNumber: “558458” can be instructed to return parts of the information within an element structure only.
  • Page 57: Xacli - Special Commands - Xfeedback

    About the TANDBERG API XACLI – Special Commands – xfeedback (I) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE EXAMPLE About the xfeedback Command To list the registered expression the sub-command list should User wants to deregister expression 2 in the left example:...
  • Page 58 About the TANDBERG API XACLI – Special Commands – xfeedback (II) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE. User wants to know when calls are connected NOTE! If sub-elements are removed from a status structure between transitions, the removed elements will be notified with an attribute...
  • Page 59: Xacli - Special Commands - Xpreferences

    About the TANDBERG API XACLI – Special Commands – xpreferences (I) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS About xpreferences xpreferences xpathwrite xpreferences detaillevel xpreferences xpathwrite <on/off> xpreferences detaillevel <1..2> xpreferences A command of great importance, lets the...
  • Page 60: Xpreferences Xmlstatusfeedback

    About the TANDBERG API XACLI – Special Commands – xpreferences (II) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS xpreferences xmlstatusfeedback xpreferences itemnumber xpreferences itemnumber <on/off> xpreferences xmlstatusfeedback <on/off> If xmlstatusfeedback is set to on, all status feedback will be returned All Status and Configuration elements consist of an element name and an in XML-format instead of the default XACLI status format (or complete path formatting).
  • Page 61: Xpreferences Completepath

    About the TANDBERG API XACLI – Special Commands – xpreferences (III) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS xpreferences completepath xpreferences completepath <on/off> Used to enable Complete Path formatting for all Status-type data. If set to on, the complete path to a status element will be supplied on all lines. RECOMMENDED to be used when parsing status information sent from the codec line by line.The specified formatting will also apply all feedback sent from the codec on this RS 232/Telnet session.
  • Page 62: Xacli - Special Commands - Xgetxml

    About the TANDBERG API XACLI – Special Commands – xgetxml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS EXAMPLE About xgetxml xgetxml status/ip As an alternative to the XACLI output format, XML format is <Status> supported through the root command xgetxml. The xgetxml <IP item=”1”>...
  • Page 63: Txas - Tandberg Xml Api Service

    About TANDBERG XML API Service Bare-bone HTTP(S) Access TXAS is a service provided by TANDBERG units for transmit- The bare-bone HTTP mode uses a unique URL to identify the specific request. The contents of ting and receiving (transceiving) information encoded in XML the HTTP body will be a XML document (or part of it).
  • Page 64: Configuration-Type Commands

    Configuration-type Commands This part of the manual describes the Configuration We recommend that you check out the TANDBERG web site regularly for updated information available. versions of this manual: There are two types of configuration-type commands http://www.tandberg.com/support/ documentation.php available: •...
  • Page 65: Understanding The Table Layout

    Example: xConfiguration AllowLatency: On Audio Microphones Mode: <On/Off> Turns all microphones On or Off. This is the configuration that is tied to the “Mic off” key on the TANDBERG MXP remote control. xconfiguration audio microphones mode: off Example: Audio MicrophoneMixer Mode: <Fixed/Auto>...
  • Page 66: Additionalcamera

    Example: xConfiguration AllowLatency: On Audio Microphones Mode: <On/Off> Turns all microphones On or Off. This is the configuration that is tied to the “Mic off” key on the TANDBERG MXP remote control. xconfiguration audio microphones mode: off Example: Audio MicrophoneMixer Mode: <Fixed/Auto>...
  • Page 67 Configuration-type Commands – xconfiguration / configuration.xml Audio TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Audio AutoMute: <On/Off/Unmute> When automute is set to On, the microphones will be turned off (muted) automatically at boot and at end of calls.
  • Page 68 Configuration-type Commands – xconfiguration / configuration.xml Audio TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Output Response Codec 3000 MXP Output Response Codec 6000 MXP Stereo Settings Audio Stereo: <On/Off> Turns stereo I/O mode On or Off. Out 1...
  • Page 69 If Out 1 Mode is set to Auto, the system will select analogue or digital (SPDIF) mode depending on the detected Audio Module. If 3000 MXP: x=2 a TANDBERG Digital NAM is detected, SPDIF mode will be selected, otherwise analogue mode will be selected. Setting the Out 1 Mode to either Analogue or SPDIF will override the auto-detected mode.
  • Page 70: Autoanswer

    Configuration-type Commands – xconfiguration / configuration.xml Audio — CallManager TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Audio Feedback Mode: <Normal/Fast> This configuration alters how fast the audio feedback will react. Set to Normal to allow for some distortion before the feedback response. When set to Fast, the audio feedback response will be faster but also more nervous.
  • Page 71: Callvideosource

    Enables or disables dual visca mode. If enabled, visca control will be available on the RJ11 connector on the camera. If disabled, the RJ11 connector will work as a normal daisy chain port. Applies to TANDBERG Precision HD cameras only.
  • Page 72: Cameradvi

    Mode: <Auto/Manual> Auto is the default and the recommended setting. However, in severe light conditions, you may switch mode to manual and specify explicitly which gamma table to use by setting the level. Applies to TANDBERG Precision HD cameras only.
  • Page 73: Cameratracking

    If set to Auto the Camera software will be automatically upgraded by the codec. If set to Off, camera software upgrade must be initiated manually by the command CameraForceUpgrade. NOTE! If codec software is downgraded the camera software must be downgraded manually by the command CameraForceUpgrade. Applies to TANDBERG Precision HD camera only! xconfiguration cameraswupgrade: Auto...
  • Page 74 Configuration-type Commands – xconfiguration / configuration.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Conference URI: <S: 0, 60> The SIP URI is the address to use when calling the system using SIP . xconfiguration conference sip uri: MySIP_URI...
  • Page 75 Configuration-type Commands – xconfiguration / configuration.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Conference AAC-LD-128-Threshold: <384/512/768/1152/1472/1920/2560/3072/4096> The system will not transmit AAC-LD-128 unless the call rate is equal to or above the specified threshold. xconfiguration conference aac-ld-128-threshold: 768...
  • Page 76 BillingCode: <On/Off> This configuration is only relevant when when placing calls using the TANDBERG remote control and the on screen menu. If set to on, all users must enter a code to identify themselves before dialling. The billing code will be attached to the call when the call is placed in the call log after it is disconnected. When placing calls using the command Dial, a billing code can be added to identify the call in the call log regardless of this setting.
  • Page 77: Corporatedirectory

    Specifies the path to the CorporateDirectory on the server. xconfiguration corporatedirectory path: TMS/Public/external/phonebook/PhoneBookService.asmx Example: CorporateDirectory Protocol: <HTTP/HTTPS> TANDBERG MXP systems now support secure management when communicating with the TMS (TANDBERG Management Suite). xconfiguration corporatedirectory protocol: Example: DefaultPIPPosition: <BottomLeft/BottomRight/TopLeft/TopRight> Specifies the default positioning of the PIP (Picture In Picture).
  • Page 78: Directory

    Configuration-type Commands – xconfiguration / configuration.xml Directory — ExternalManager TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Directory CallLog: <On/Off> Enable/disable Call Logs for Placed calls, Missed calls and Received calls in the Phone Book. xconfiguration directory calllog: on...
  • Page 79: Externalnetwork

    If turned on, a menu choice will appear in the services xconfiguration externalservices address: 10.47.6.75 Example: menu, and on entering this the TANDBERG unit will retrieve a default XHTML page as specified in the Exter- nal Services configuration menu. ExternalServices Path: <S: 0, 255>...
  • Page 80: Fecc

    Configuration-type Commands – xconfiguration / configuration.xml ExternalServices — G703 TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS ExternalServices Protocol: <HTTP/HTTPS> Enables/disables secure management. xconfiguration externalservices protocol: http Example: FECC Mode: <On/Off> Sets whether or not to allow the remote site to control the cameras connected to the system.
  • Page 81: H320

    Configuration-type Commands – xconfiguration / configuration.xml G703 — H323Gatekeeper TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS G703 Interface MaxChannels: <1..30/23> Indicates the maximum number of channels the codec is allowed to use on the E1/T1 interface. When E1 is selected, maximum is 30 channels. When T1 is selected, maximum is 24 channels.
  • Page 82 The system sends the Authentication ID and Password to a Gatekeeper for authentication. The authentication is a one way authentication from the endpoint system to a Gatekeeper, i.e. the endpoint is authenticated to the Gatekeeper. If the Gatekeeper indicates that no authentication is required, the endpoint will still try to register. xconfiguration h323gatekeeper authentication id: TANDBERG Example: D 13887.08...
  • Page 83: H323Prefix

    VerifyServerCertificate: <On/Off> TANDBERG MXP systems now support secure management when communicating with the TMS. For more information see the TANDBERG White Paper “Implementing Secure Management” which describes how to configure secure HTTPS between TANDBERG products. To find the document, follow the link: http://www.tandberg.com/support/ documentation.php and select White Papers.
  • Page 84: Ieee802.1X

    Configuration-type Commands – xconfiguration / configuration.xml IEEE802.1x — IMUX TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS IEEE802.1x Mode: <On/Off> Enables/disables 802.1x authentication xconfiguration ieee802.1x mode: on Example: IEEE802.1x AnonymousIdentity: <S: 0, 64> The 802.1x Anonymous ID string is to be used as unencrypted identity with EAP types that support different tunneled identity, EAP-PEAP and EAP-TTLS.
  • Page 85 Configuration-type Commands – xconfiguration / configuration.xml IMUX TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS IMUX Custom BW64R Suffix: <S: 0, 12> Defines the suffix to be used with the RS366 Custom IMUX at this restricted bandwidth. xconfiguration imux custom bw64r suffix: xxx...
  • Page 86 Configuration-type Commands – xconfiguration / configuration.xml IMUX TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS IMUX Custom BW256 Suffix: <S: 0, 12> Defines the suffix to be used with the RS366 Custom IMUX at this bandwidth. xconfiguration imux custom bw256 suffix: xxx...
  • Page 87 Configuration-type Commands – xconfiguration / configuration.xml IMUX TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS IMUX Custom BW384R Suffix: <S: 0, 12> Defines the suffix to be used with the RS366 Custom IMUX at this restricted bandwidth. xconfiguration imux custom bw384r suffix: xxx...
  • Page 88 Configuration-type Commands – xconfiguration / configuration.xml IMUX TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS IMUX Custom BW1152 Suffix: <S: 0, 12> Defines the suffix to be used with the RS366 Custom IMUX at this bandwidth. xconfiguration imux custom bw1152 suffix: xxx...
  • Page 89: Integrator

    Example: xconfiguration integrator amxbeacon mode: off Integrator Telepresence Mode: <Off/Point2Point/MultiPoint/Briefer> Only in use with TANDBERG Experia. xconfiguration integrator telepresence mode: off Example: Assignment: <DHCP/Static> Defines whether to use DHCP or Static IP assignment. NOTE! This configuration only applies to IPv4.
  • Page 90: Ipmedia

    Defines what IP protocol to use. If set to Both the system will support both IPv4 and IPv6. xconfiguration ipprotocol: both Example: IRControl Mode: <On/Off> Enables/disables the TANDBERG Remote Control. Example: xconfiguration ircontrol mode: off IRControl NumberKeyMode: <AddCall/DTMF/Presets/Manual> When pressing a number key on the remote control, while in a call, the user can decide what shall happen. The system can be configured to act automatically or manually.
  • Page 91 Configuration-type Commands – xconfiguration / configuration.xml ISDN TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS ISDN ParallelDial: <On/Off> When set to On, channels will be dialed and connected in parallel when setting up a BONDING call. When set to Off, channels will be dialled one by one, which may increase the dialling time.
  • Page 92 Configuration-type Commands – xconfiguration / configuration.xml ISDN TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS ISDN NSFTelephony Number: <0..31> Service profiles for Sprint (ref. 2): NSF Service Defines what Service Facility to use for telephony if the NSFTelephony Mode is set to On.
  • Page 93 Configuration-type Commands – xconfiguration / configuration.xml ISDN TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS ISDN L2WindowSize: <1..7> Max. No. of outstanding Iframes (ISDN Layer 2) xconfiguration isdn pri L2windowsize: Example: ISDN Interface MaxChannels: <1..30> Maximum number of channels the system may use at any given time.
  • Page 94: Keyboard

    Enables (On) or diables (Off) Kiosk mode. xconfiguration kiosk mode: on Example: Number0: <On/Off> Enable or disable the given key on the TANDBERG Remote Control, and using configuration instead of commands. Example: xconfiguration key number0: on Number1: <On/Off> Enable or disable the given key on the TANDBERG Remote Control, and using configuration instead of commands.
  • Page 95 Enable or disable the given key on the TANDBERG Remote Control, and using configuration instead of commands. xconfiguration key number9: on Example: Star: <On/Off> Enable or disable the given key (*) on the TANDBERG Remote Control, and using configuration instead of commands. Example: xconfiguration key star: on Square: <On/Off>...
  • Page 96 Enable or disable the given key (green Call key) on the TANDBERG Remote Control, and using configuration instead of commands. xconfiguration key connect: on Example: Disconnect: <On/Off> Enable or disable the given key (red End Call key) on the TANDBERG Remote Control, and using configuration instead of commands. xconfiguration key disconnect: on Example: Up: <On/Off>...
  • Page 97 Enable or disable the given key (Zoom –) on the TANDBERG Remote Control, and using configuration instead of commands. xconfiguration key zoomout: on Example: Grab: <On/Off> Enables/disables the signal which is sent to the codec when grabbing and touching the rubber lines on each side of the TANDBERG Remote Control. xconfiguration key grab: on Example: Cabinet: <On/Off>...
  • Page 98: Kiosk

    & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS FarEnd: <On/Off> Enable or disable the given key on the TANDBERG Remote Control (TRC4), and using configuration instead of commands. xconfiguration key farend: on Example: Services: <On/Off> Enable or disable the given key on the TANDBERG Remote Control (TRC4), and using configuration instead of commands.
  • Page 99 Configuration-type Commands – xconfiguration / configuration.xml Kiosk TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Kiosk LanguageMenu English: <On/Off> Enables (On) or diables (Off) language menu in English. xconfiguration kiosk languagemenu english: on Example: Kiosk LanguageMenu German: <On/Off>...
  • Page 100: Locallayout

    Logo: <On/Off> If set to On the system will display a company logo will appear in the background of the welcome menu. NOTE! The TANDBERG logo will be displayed if no other company logo is uploaded. xconfiguration logo: on Example: Duration Exponent: <10..30>...
  • Page 101: Mainvideosource

    Configuration-type Commands – xconfiguration / configuration.xml — NetProfile TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Initial: <0..65534> LoS configurations are relevant Specifies the maximum number of seconds to wait for H.221 frame alignment during call setup before asserting the LOS signal.
  • Page 102: Ntp

    Configuration-type Commands – xconfiguration / configuration.xml NetProfile — OSD TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS NetProfile [1..7] CallPrefix: <S: 0, 9> A call prefix can be added to each NetProfile. If a call prefix is added, this prefix will automatically be added in front of the number being dialled. This is useful if you have a fixed prefix for a specific service provider.
  • Page 103 Configuration-type Commands – xconfiguration / configuration.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Mode: <On/Off> Enables/disables the On Screen Display (OSD). If set to Off there will be no graphics displayed on the monitors. xconfiguration osd mode: on...
  • Page 104 Configuration-type Commands – xconfiguration / configuration.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Menu InputEditor Language: <Off/Chinese/Korean/Japanese> When the Input Editor Language is set to Chinese, Korean or Japanese the user will be able to enter Chinese/Korean/Japanese characters into an input field like the System Name or Phone Book, using the remote control.
  • Page 105: Pictureprogram

    Configuration-type Commands – xconfiguration / configuration.xml — PacketLossDownspeed TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Icon Warning: <On/Off> Enables/Disables the Warning icon. xconfiguration osd icon warning: on Example: MCUStatusLine Mode: <On/Off/Auto> If set to On the MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference.
  • Page 106: Preset

    1 duovideosource: 1 Example: tions are offset by 1. Preset [1..15] SwitchVideoSource: <0/1/2/3/4/5/6> Will switch the TANDBERG Video Switch to the given input when the preset is activated. xconfiguration preset 1 switchvideosource: 1 Example: Preset [1..15] Camera Brightness Mode: <Manual/Auto>...
  • Page 107 Configuration-type Commands – xconfiguration / configuration.xml Prest TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Preset [1..15] Camera Brightness Level: <0..16> Interpretation of the settings chosen will depend on the camera type you use. If in doubt, consult your camera’s user documentation.
  • Page 108: Qos

    Configuration-type Commands – xconfiguration / configuration.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Precedence Telephony Audio: <0/1/2/3/4/5/6/7/Auto/Off> xconfiguration qos precedence telephony audio: auto Example: Precedence Telephony Signalling: <0/1/2/3/4/5/6/7/Auto/Off> Example: xconfiguration qos precedence telephony signalling: auto Configures the different Quality...
  • Page 109 Configuration-type Commands – xconfiguration / configuration.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Precedence VideoTelephony Data: <0/1/2/3/4/5/6/7/Auto/Off> xconfiguration qos precedence videotelephony data: auto Example: Diffserv Telephony Audio: <0..63> Example: xconfiguration qos diffserv telephony audio: 15 DiffServ Telephony Signalling: <0..63>...
  • Page 110: Remoteswupgrade

    Configuration-type Commands – xconfiguration / configuration.xml RemoteSwUpgrade — SerialPort TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS RemoteSwUpgrade Mode: <On/Off> If set to On, software can be upgraded from a far end system. xconfiguration remoteswupgrade mode: on Example: RemoteSwUpgrade Password: <S: 0, 16>...
  • Page 111: Sip

    Configuration-type Commands – xconfiguration / configuration.xml SerialPort — SIP TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS SerialPort [1] Direct Buffer: <0..16384> NOTE! Port 1 Only Specifies the size of the buffer used in direct mode. Try setting this value higher if you need a continuous stream of data on the receiving end. Higher values introduces more delay.
  • Page 112: Snmp

    Configuration-type Commands – xconfiguration / configuration.xml — SNMP TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Server Type: <Auto/Nortel/Microsoft/Cisco/Siemens/Alcatel/Experimental> Enables SIP extensions and special behaviour for a SIP Server vendor. Auto: Should be used when registering to standard SIP servers like OpenSer.
  • Page 113: Startupvideosource

    If set to Off, it will not be possible to connect to the system using SSH. The Command Line Interface can be accessed using SSH (Secure Shell), which allows for secure control of the TANDBERG MXP . Example: xconfiguration SSH Mode: On D 13887.08...
  • Page 114: Streaming

    = ITU ratified way of xconfiguration streaming announcements: on Example: sending Dual Images. TANDBERG uses Dual Stream to Streaming Source: <Local/Remote/Auto> cover both these two technolo- Select streaming source as Local, Remote or Auto. If set to Auto the streaming will be voice switched. The site currently speaking will be gies.
  • Page 115: Strictpassword:

    If the switch is connected with no special configuration, selecting “main cam” in the menu will give the current input 3 Doc Cam on the switch. Default value is Off. 4 VCR Will set the logical input on the TANDBERG Video Switch to the given mode. 5 PC xconfiguration switch logicalinput 1 mode: On Example: Switch LogicalInput [1..5]...
  • Page 116: Telnet

    Configuration-type Commands – xconfiguration / configuration.xml SystemUnit — Time TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS SystemUnit DisplayName: <S: 0, 50> The Display Name part of the SIP Address (URI) xconfiguration systemunit displayname: MyDisplayNmae Example: SystemUnit Password: <S: 0, 16>...
  • Page 117: Useaslocalpcmonitor

    Configuration-type Commands – xconfiguration / configuration.xml Time — Video TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Time TimeFormat: <24H/12H> Specifies the time format to use. xconfiguration time timeformat: 24h Example: Time DaylightSavings: <On/Off> Enables/Disables Daylight Savings. xconfiguration time daylightsavings: on Example: UseAsLocalPCMonitor: <On/Off>...
  • Page 118 Configuration-type Commands – xconfiguration / configuration.xml Video TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Video Inputs Source [1..6] Quality: <Motion/Sharpness> When encoding and transmitting video there will be a tradeoff between high resolution and high framerate. For some video sources it is more important to transmit high framerate than high resolution and vice versa.
  • Page 119 If DVIResolution is Auto and AllowHD720p is on, the system will allow HD720p (1280x720) to be considered when determining the best output resolu- tion, even if the attached monitor’s support for this resolution has not been tested and verified by TANDBERG.
  • Page 120 Configuration-type Commands – xconfiguration / configuration.xml Video TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Video Outputs Letterbox: <On/Off> This setting will only take effect on video displayed in full screen. When set to On, the system will use horizontal black bars to compensate for aspect ratio mismatch between a wide output and a narrow input.
  • Page 121: Vnc

    Configuration-type Commands – xconfiguration / configuration.xml Video — VNC TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Video Outputs DVI [1..x] Mode: <On/Off> x = 2 on 6000 MXP Turns On/Off the DVI outputs. NOTE! We recommend that you turn off video all unused video outputs.
  • Page 122: Localentry - Groupentry

    Configuration-type Commands – xdirectory / directory.xml LocalEntry — GroupEntry TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS LocalEntry [1..200] Name: <S: 0, 48> The local entry’s name. xdirectory localentry 26 name: john doe Example: LocalEntry [1..200] Number: <S: 0, 60>...
  • Page 123: Globalentry

    Configuration-type Commands – xdirectory / directory.xml GlobalEntry TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS GlobalEntry [1..400] Name: <S: 0, 48> The global entry’s name. Example: xdirectory globalentry 26 name: john doe GlobalEntry [1..400] Number: <S: 0, 60> The global entry’s number.
  • Page 124: Configuration Storage Levels

    Configuration Storage Levels You may reset configuration settings to their default We recommend that you check out the TANDBERG web site regularly for updated values. Whether a specific configuration command will be versions of this manual: affected by the reset command depends on two things;...
  • Page 125: Understanding The Table Layout

    PictureProgram [1..4] Window [1..6] Picture: <LocalMain/LocalDuo/Current/Previous/Duo/RemoteMain/RemoteDuo/JPEG/ TandbergMonitor1/TandbergMonitor2/None> reset (1, 2, and 3). D 13887.X3 AUGUST 2006 An exhaustive TIP! description of the API Configuration Command structure can be found in the section Corresponding Storage Level The TANDBERG API D 13887.08 MAY 2008...
  • Page 126 Configuration Storage Levels AdditionalCamera — Audio MicrophoneMixer Mode TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: AdditionalCamera Type: <0..4> AlertSpeaker Mode: <On/Off> AlertTone Telephony: <1..10> AlertTone VideoTelephony: <1..10> AlertTone Volume: <0..15> AllowLatency: <On/Off> Audio AGC AUX: <On/Off>...
  • Page 127 Configuration Storage Levels Audio Microphones Mode — Camera [1..13] WhiteBalance Level TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Audio Microphones Mode: <On/Off> Audio Outputs Line [1..3] Level: <1..16> Audio Outputs Line [1..3] Mode: <On/Off> Audio Outputs Line 1 Type: <Analog/SPDIF/Auto>...
  • Page 128 Configuration Storage Levels Camera [1..13] WhiteBalance Mode — Conference H263 TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Camera [1..13] Whitebalance Mode: <Manual/Auto> CameraDVI Mode: <On/Off/Auto> CameraSleep Mode: <On/Off> CameraSwUpgrade: <Auto/Off> CameraTracking Speed: <Slow/Normal/Fast> Conference AAC-LD: <On/Off>...
  • Page 129 Configuration Storage Levels Conference H264 — ExternalNetwork Clocking TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Conference H264: <On/Off> Conference H264RCDO: <On/Off> Conference H323Alias E164: <E164: 0, 30> Conference H323Alias ID: <S: 0, 49> Conference H331: <On/Off>...
  • Page 130 Configuration Storage Levels ExternalNetwork DTRPulse — H323Prefix TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: ExternalNetwork DTRPulse: <On/Off> ExternalServices Address: <S: 0, 64> ExternalServices Mode: <On/Off> ExternalServices Path: <S: 0, 255> FECC Mode: <On/Off> FeedbackFilter Call: <0..10>...
  • Page 131: Http Mode - Ipprotocol

    Configuration Storage Levels HTTP Mode — IPProtocol TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: HTTP Mode: <On/Off> HTTPS Mode: <On/Off> IdReport H323: <H323Id/E164Alias/IPAddress> IEEE802.1x AnonymousIdentity: <S: 0, 64> IEEE802.1x EAP-MD5: <On/Off> IEEE802.1x EAP-PEAP: <On/Off> IEEE802.1x EAP-TTLS: <On/Off>...
  • Page 132 Configuration Storage Levels IRControl NumberKeyMode — ISDN PRI Interface Search TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: IRControl NumberKeyMode: <AddCall/DTMF/Presets/Manual> IRControl Mode: <On/Off> ISDN BRI Alert: <On/Off> ISDN BRI AutoActivation: <Off/Selected/All> ISDN BRI ChanId: <On/Off>...
  • Page 133 Configuration Storage Levels ISDN PRI L2WindowSize — LocalLayout Toggle TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: ISDN PRI L2WindowSize: <1..7> ISDN PRI NSFTelephony Mode: <On/Off> ISDN PRI NSFTelephony Number: <0..31> ISDN PRI NSFVideoTelephony Mode: <On/Off>...
  • Page 134 Configuration Storage Levels Logo — OptionKey Features TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Logo: <On/Off> LoS Duration Exponent: <10..30> LoS Duration Offset: <0..65534> LoS Inhibit: <0..65534> LoS Initial: <0..65534> LoS Polarity: <Positive/Negative> LoS Retry: <0..65534>...
  • Page 135 Configuration Storage Levels OSD Icon BadNetwork — Preset [1..15] Camera Autofocus TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: OSD Icon BadNetwork: <On/Off> OSD Icon Encryption: <On/Off> OSD Icon MicOff: <On/Off> OSD Icon OnAir: <On/Off> OSD Icon Telephone: <On/Off>...
  • Page 136 Configuration Storage Levels Preset [1..15] Camera Brightness — RemoteSwUpgrade Password TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Preset [1..15] Camera Brightness Level: <0..16> Preset [1..15] Camera Brightness Mode: <Manual/Auto> Preset [1..15] Camera Focus: <0..65534> Preset [1..15] Camera Pan: <-32768..32767>...
  • Page 137 Configuration Storage Levels RTP MTU — SSH Mode TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: RTP MTU: <400..1400> RTP Ports: <Static/Dynamic> Screensaver Delay: <1..480> Screensaver Mode: <On/Off> SelfViewOnStartup: <On/Off> SerialPort [1..2] BaudRate: <1200/2400/4800/9600/19200/38400/57600/115200> SerialPort [1..2] DataBits: <7/8>...
  • Page 138 Configuration Storage Levels StartupVideoSource — UseAsLocalPCMonitor TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: StartupVideoSource: <0/1/2/3/4/5/6> StillImageSource: <0/1/2/3/4/5/6> Streaming Address: <S: 0, 64> Streaming AllowRemoteStart: <On/Off> Streaming Announcements: <On/Off> Streaming Hops: <0..255> Streaming Password: <S: 0, 16>...
  • Page 139: Video Inputs Source [1..6] Name - Vnc Password

    Configuration Storage Levels Video Inputs Source [1..6] Name — VNC Password TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Storage Level: Configuration: Video Inputs Source [1..6] Name: <S: 0, 16> Video Inputs Source [1..6] Quality: <Motion/Sharpness> Video Outputs AllowHD720p: <On/Off>...
  • Page 140: Command Information Tables

    Command Information Tables This part of the manual describes the Command We recommend that you check out the TANDBERG web site regularly for updated Information available. versions of this manual: http://www.tandberg.com/support/ documentation.php...
  • Page 141: Understanding The Table Layout

    – see the column Example for an illustration of this. Empty lines in the examples provided may have been removed to save space in the tables. D 13887.X3 AUGUST 2006 An exhaustive TIP! description of the API structure can be found in the section The TANDBERG API D 13887.08 MAY 2008...
  • Page 142: Alerttonetest

    Command Information AlertToneTest — AudioTestSignal TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand alerttonetest tone:5 AlertToneTest None Cause: <1…> Command used to Tone(r): <1..10> *r Result (status=OK):...
  • Page 143: Boot

    Command Information Boot — CallMuteOutgoing TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand boot parameterrestore: on Boot None As above. Command used to ParameterRestore: <On/Off> *r Result (status=OK): reboot the system.
  • Page 144: Callsetaudiotp

    None As above Command used to Camera(r): <1..13> *r Result (status=OK): initiate software *r/end upgarde of the TANDBERG Precision HD Camera. Should only be used after downgrade of the TANDBERG MXP Codec software or if the configuration CameraSwUpgrade is set to Off. When the...
  • Page 145: Cameramove

    Focus: <0..65534> Focus value. NOTE! The supported values for pan, tilt, zoom, focus will depend on the type of camera in use. For example: Sony cameras have value ranges different from TANDBERG cameras. xcommand camerareconfigure CameraReconfigure Re-configures all None None...
  • Page 146: Cameratrackingstart

    Upgrade camera or *r Result (status=OK): video switch with new Addresses the specific camera or *r/end software. The software TANDBERG Video Switch. must be put on a folder Camera software files are named named either /tmp or s01692.pkg. /user. Video Switch software files are Currently only upgrading named s51200.pkg.
  • Page 147: Conferencedisconnect

    Command Information ConferenceDisconnect — ConferenceTerminate TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand ConferenceDisconnect ConferenceDisconnect None As above Command used to None *r Result (status=OK): disconnect all calls...
  • Page 148: Corpdirsearch

    Command Information CorpDirSearch TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand corpdirsearch CorpDirSearch None As above Command to search With no parameters specified the *r Result (status=OK): for contacts in the result will show the first 40 catalogs.
  • Page 149: Corpdirgetnext

    Command Information CorpDirGetNext TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand corpdirgetnext path:138 query: CorpDirGetNext None As above After having used the With no parameters specified the...
  • Page 150: Corpdirgetprevious

    Command Information CorpDirGetPrevious TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand corpdirgetprevious path:138 CorpDirGetPrevious None As above After having used the With no parameters specified the...
  • Page 151: Defaultvaluesset

    Command Information DefaultValueSet TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand defaultvaluesset level:2 DefaultValuesSet None As above Command used to reset Level: <1..3> *r Result (status=OK):...
  • Page 152: Dial

    Command Information Dial TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand dial number:123 callrate:256 Dial As above Command used to dial Number: <S: 0, 60> CallRef: <1..11>...
  • Page 153: Dialglobalentry

    Command Information DialGlobalEntry — DialLocalEntry TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand dialglobalentry globalentry- DialGlobalEntry As above Command used to dial a GlobalEntryId(r): <1..400> CallRef: <1..11>...
  • Page 154: Disconnectcall

    Command Information DisconnectCall — FECCFocus TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand disconnectcall call:9 DisconnectCall None As above Command used to Call: <1..11> *r Result (status=OK): disconnect a call.
  • Page 155: Feccmove

    Command Information FECCMove — FeedbackDeregister TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand feccmove direction:right FECCMove None As above Command used Direction(r): <up/Down/Right/Left/ *r Result (status=OK): to issue a Far End In/Out/FocusIn/FocusOut>...
  • Page 156: Feedbackregister

    Command Information FeedbackRegister — FloorRequest TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand feedbackregister url:http://10. FeedbackRegister As above Command used to ID: <1..3> ID: <1..3> 47.14.185:8000 instruct the system to ID for the registration.
  • Page 157: Floortosite

    KeyDown None As above Command used to Key(r): <0/1/2/3/4/5/6/7/8/ *r Result (status=OK): emulate pressing a key 9/*/#/Connect/Disconnect/ *r/end on the TANDBERG MXP up/Down/Right/Left/Selfview/ remote control without Layout/Phonebook/Cancel/ releasing it. The KeyDown MicOff/Presentation/Volumeup/ command should be VolumeDown/OK/ZoomIn/ followed by a KeyRelease ZoomOut/Grab>...
  • Page 158: Keyrelease

    KeyPress None As above Command used to Key(r): <0/1/2/3/4/5/6/7/8/ *r Result (status=OK): emulate pressing a 9/*/#/Connect/Disconnect/ *r/end key on the TANDBERG up/Down/Right/Left/Selfview/ MXP remote control Layout/Phonebook/Cancel/ for a short while. This MicOff/Presentation/Volumeup/ command needs no VolumeDown/OK/ZoomIn/ release command. ZoomOut/Grab>...
  • Page 159: Localentryadd

    Command Information LocalEntryAdd — MessageBoxDelete TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand localentryadd name:”John Galt” LocalEntryAdd As above Command used to Name: <S: 0, 48>...
  • Page 160: Messageboxdisplay

    Command Information MessageBoxDisplay — PresetActivate TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand messageboxdisplay title:Welcome MessageBoxDisplay None As above Command used to add a Title(r): <S: 0, 40>...
  • Page 161: Presetclear

    Command Information PresetClear — ScreensaverActivate TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand presetclear number:4 PresetClear None As above Command used to clear Number(r): <0..14> *r Result (status=OK): a preset previously The preset to clear.
  • Page 162: Screensaverdeactivate

    Command Information ScreensaverDeactivate — SiteViewEnd TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand screensaverdeactivate ScreensaverDeactivate None As above Command used to None *r Result (status=OK): deactivate screensaver.
  • Page 163: Spidautoconfigure

    Command Information SPIDAutoConfigure — TextDisplay TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand spidautoconfigure SPIDAutoConfigure None As above Command used to None *r Result (status=OK): initiate automatic *r/end configuration of SPIDs.
  • Page 164: Virtualmonitorreset

    Command Information VirtualMonitorReset — VirtualMonitorSet TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Description Parameters Result parameters Result parameters Example when OK when error xcommand virtualmonitorreset virtual- VirtualMonitorReset None As above Command used to VirtualMonitor(r): <1..4> monitor:2 reset a VirtualMonitor.
  • Page 165: Status Information Tables

    Status Information Tables This part of the manual describes the Status information We recommend that you check out the TANDBERG web site regularly for updated available. versions of this manual: There are three types of status information available: http://www.tandberg.com/support/ documentation.php •...
  • Page 166: Understanding The Table Layout

    Status Information Understanding the Table Layout TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS The status element listed means logical on this page Status Information Conference TANDBERG 3000 & 6000 REFERENCE USER GUIDE FOR SYSTEM INTEGRATORS The status element...
  • Page 167: Audio

    Status Information – xstatus /xstatus.xml Audio TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Audio AudioModule: None / NAMI / NAMII / Digital NAM / mDNAM Inputs Microphone [1..3]: Active: True / False Line [1..3]: Active: True / False...
  • Page 168: Bri

    Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Unknown / True / False) BRI [1..6] (ready= Unknown / True, the following will be included: If ready = Channel [1..2] BChannel status=Idle / Calling / Answering / Proceeding / Connect / Disconnecting /...
  • Page 169 Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example: *s BRI 1 (ready=True): Channel 1 (type=BChannel, status=Idle): / Channel 2 (type=BChannel, status=Disconnected): CallingNumber: “8770” CauseLocation: 0 ChannelCause: 41 ConnectionTime: 258 *s/end *s BRI 2 (ready=True): Channel 1 (type=BChannel, status=Connect): CallingNumber: “8770”...
  • Page 170: Call

    Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS (status=Disconnected / CallIDLE / Dialing / Alerting / Proceeding / EstablOut / EstablIn / AwaitInCnf / Connected / Disconnecting / Await2ndnr / ClearOut / ClearIn / Syncing / Capex / Synced / Unframed, Call [1..10]...
  • Page 171 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Inactive If status = the following will be included <Nothing> Active If status = the following will be included Protocol: G711 / G722 / G722.1 / G728 / AAC-LD Rate: 16...
  • Page 172 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Dialing / Alerting / Proceeding / EstablOut / EstablIn / AwaitInCnf / Connected / Disconnecting / Await2ndnr / ClearOut / ClearIn / Syncing / Capex / Synced / Unframed...
  • Page 173 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Protocol: G711 / G722 / G722.1 / G728 /AAC-LD Rate: Video [1..2] Active / Inactive): (status = Inactive If status = the following will be included: <Nothing>...
  • Page 174 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example (see previous page for the status information applicable): *s Call 1 (status=Synced, type=Vtlph, protocol=H320, direction=Outgoing, logTag=3): CallRate: 384 Bonding: On RemoteNumber 1: “8776”...
  • Page 175 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Dialing / Alerting / Proceeding / EstablOut / EstablIn / AwaitInCnf / Connected / Disconnecting / Await2ndnr / ClearOut / ClearIn / Syncing / Capex / Synced / Unframed...
  • Page 176 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS PacketsDropped*: Appears with incoming calls only Example: *s Call 1 (status=Synced, type=Tlph, protocol=H323, direction=Incoming, logTag=5): CallRate: 64 RemoteNumber: “5020019” IncomingNumber: “5020059” IncomingSubAddress: “” Mute: Off...
  • Page 177 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Dialing / Alerting / Proceeding / EstablOut / EstablIn / AwaitInCnf / Connected / Disconnecting / Await2ndnr / ClearOut / ClearIn / Syncing / Capex / Synced / Unframed...
  • Page 178 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Active If status = the following will be included: Protocol: G711 / G722 / G722.1 / G728 / AAC-LD Rate: RemoteIPAddress*: LocalIPAddress*: Encryption* On /...
  • Page 179 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS If status = the following will be included: Type: DES / AES-128 RSVP*: On / Off DynamicRate*: TotalPackets*: PacketLoss*: Jitter*: PacketsDropped*: Appears for incoming calls only...
  • Page 180 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example: *s Call 1 (status=Synced, type=Vtlph, protocol=H323, direction=Incoming, logTag=6): CallRate: 768 RemoteNumber: “5020019” IncomingNumber: “5020059” IncomingSubAddress: “” Mute: Off Microphone: On Duration: 10 MuteOutgoing: Off...
  • Page 181 Status Information – xstatus /xstatus.xml Call TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS TotalPackets: 817 PacketLoss: 0 Jitter: 0 PacketsDropped: 0 Video 2 (status=Inactive): / Data (status=Inactive): / Channels 2 (type=Outgoing): Rate: 768 Restrict: Off Encryption (status=On): Type: AES-128 CheckCode: “C442803A9A470B7F”...
  • Page 182: Camera

    Status Information – xstatus /xstatus.xml Camera TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Camera [1..13] (connected = True / False): Type: Pan: Tilt: Zoom: Focus: Example: *s Camera 1 (connected=True): Type: WaveII ID: “0c0e0006” SoftwareID: “” Pan: 647...
  • Page 183: Cameraswupgrade

    Status Information – xstatus /xstatus.xml CameraSWUpgrade TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CameraSWUpgrade (status = N/A): Example: *s CameraSwUpgrade (status=NA): / *s/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 184: Cameratracking

    Status Information – xstatus /xstatus.xml CameraTracking TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CameraTracking (status = On / Off): On / Off If status = the following will be included: <Nothing> Example: *s CameraTracking (status=Off): / *s/end *s CameraTracking (status=On): /...
  • Page 185: Conference

    Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Conference (type = Idle / PointToPoint / PointToMultiSite / MultiSite): Idle If type = the following will be included: <Nothing> Example: *s Conference (type=Idle): /...
  • Page 186 Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS If status = the following will be included: CallRef [1..11]: 0..11 LoudestParticipant: CallRef: 0..11 NumberOfSites: 1..191 MCUSiteList: Site [1..191]: MCUID: TerminalID: Name: CallRef: LocalSite:...
  • Page 187 Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example: *s Conference (type=PointToMultisite): Calls: CallRef 1: 1 DuoVideo (status=None): / LoudestParticipant: CallRef: 1 NumberOfSites: 3 MCUSiteList: Site 1: MCUID: 85 TerminalID: 3 Name: “Boardroom1”...
  • Page 188 Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS CallRef: 0..11 Floor: None / FloorRequest / FloorAssign Current: CallRef: 0..11 Previous: CallRef: 0..11 OutgoingPicture [1..3] Current / Previous / Duo): (name = Current / Previous / Duo...
  • Page 189 Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS View: MCUID: TerminalID: Example *s Conference (type=Multisite): Calls: CallRef 1: 1 CallRef 2: 2 DuoVideo (status=Ready): / LoudestParticipant: CallRef: 2 Floor: None Current: CallRef: 2...
  • Page 190 Status Information – xstatus /xstatus.xml Conference TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Continued from the previous page: Name: “john.doe.150” CallRef: 2 Site 3: MCUID: 1 TerminalID: 4 Name: “john.doe.mxp” CallRef: 0 LocalSite: Self: MCUID: 1 TerminalID: 4...
  • Page 191: Ethernet

    Status Information – xstatus /xstatus.xml Ethernet TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Ethernet: MacAddress: Speed: 10half / 10full / 100half / 100full Example: *s Ethernet: MacAddress: “00:50:60:01:85:F1” Speed: 100full *s/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 192: Externalmanager

    Status Information – xstatus /xstatus.xml ExternalManager TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS ExternalManager: Address: Protocol: HTTP / HTTPS URL: Example: *s ExternalManager: Address: “10.47.6.75” Protocol: HTTP URL: “tms/public/external/management/SystemManagementService.asmx” *s/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 193: Externalnetwork

    Status Information – xstatus /xstatus.xml ExternalNetwork TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS ExternalNetwork (ready = True / False): False If ready = the following will be included: <Nothing> True If ready = the following will be included:...
  • Page 194: Farendinformation

    Status Information – xstatus /xstatus.xml FarEndInformation TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS FarEndInformation: FECC On / Off) (status = If status = the following will be included: <Nothing> T140: SString: Example: *s FarEndInformation: FECC (status=Off): / T140: Off...
  • Page 195 Status Information – xstatus /xstatus.xml FarEndInformation TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example: *s FarEndInformation: FECC (status=On): NumberOfPresets: 15 NumberOfSources: 5 Source 1: Name: “main cam” Capabilities: “ptzfms” Source 2: Name: “aux” Capabilities: “ms” Source 3: Name: “doc cam”...
  • Page 196: Feedback

    Status Information – xstatus /xstatus.xml Feedback TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Feedback [1..3] (status = On / Off): If status = the following will be included: <Nothing> Example: *s Feedback 1 (status=Off): / *s/end If status =...
  • Page 197: G703

    Status Information – xstatus /xstatus.xml G703 TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS G703 (ready = True / False) False If ready = the following will be included: Layer1Alarm: RedAlarm / YellowAlarm / BlueAlarm True If ready = the following will be included: Channel [1..24 / 31]...
  • Page 198: H323Gatekeeper

    Status Information – xstatus /xstatus.xml H323Gatekeeper TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS H323Gatekeeper Required / Discovering / Discovered / Authenticating / Authenticated / Registering / Registered / Rejected / Inactive) (status = Inactive If status = the following will be included: <Nothing>...
  • Page 199 Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Address: SubnetMask: Gateway: Adress [1..2] NA / IPv4 / IPv6): (type = DNS: Server [1..5]: Address: Domain: Name: Example: *s IP Address: “10.47.11.179” SubnetMask: “255.255.248.0” Gateway: “10.47.8.1”...
  • Page 200: Ntp

    Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS NTP: Address: Example: *s NTP: Address: “10.0.0.2” *s/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 201: Pri

    Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS PRI (ready = True / False) False If ready = the following will be included: Layer1Alarm: RedAlarm / YellowAlarm / BlueAlarm Example: *s PRI (ready=False): Layer1Alarm: RedAlarm...
  • Page 202 Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Example: *s PRI (ready=True): BChannelsTotal: 8 BChannelsFree: 8 H0ChannelsFree: 1 Channel 1 (type=BChannel, status=Connect): CallingNumber: “6700” ConnectionTime: 18 Channel 2 (type=BChannel, status=Idle): / Channel 3 (type=BChannel, status=Disconnected): CallingNumber: “6700”...
  • Page 203 Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Channel 10 (type=BChannel, status=Disconnected): CallingNumber: “08733” CauseLocation: 0 ChannelCause: 16 ConnectionTime: 120 Channel 11 (type=BChannel, status=Disconnected): CallingNumber: “08733” CauseLocation: 0 ChannelCause: 16 ConnectionTime: 56 Channel 12 (type=BChannel, status=Disconnected): CallingNumber: “08733”...
  • Page 204: Remoteswupgrade

    Status Information – xstatus /xstatus.xml RemoteSwUpgrade TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS RemoteSwUpgrade (status = NA / Started / Checking / Completed / Aborted / NotValid / RestoringSettings / Failed/WrongPassword / Granted / NoDataLink / WrongFormat / ErrorWrite / WrongReleaseKey / Incompatible / FileToo-...
  • Page 205: Screensaver

    Status Information – xstatus /xstatus.xml Screensaver TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Screensaver (status = On / Off) If status = the following will be included: <Nothing> Example: *s Screensaver (status=On): / *s/end If status = the following will be included:...
  • Page 206: Sip

    Status Information – xstatus /xstatus.xml TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Server Inactive / DNSFailed / Timeout / NoConnectionTCP / NoConnectionTLS / Active / Unknown) (status = Inactive If status = the following will be included: <Nothing>...
  • Page 207: Softwareupgrade

    Status Information – xstatus /xstatus.xml SoftwareUpgrade TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS SoftwareUpgrade (status = NA / Started / Checking / Completed / Aborted / NotValid / RestoringSettings / Failed) Started If status = the following will be included:...
  • Page 208: Switch

    Status Information – xstatus /xstatus.xml Switch TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Switch (connected = True / False): Input: Format: Sync: Sync 1: Sync 2: Sync 3: Sync 4: Example: *s Switch (connected=True): Input: 1 Format: 1280X720p60...
  • Page 209 Status Information – xstatus /xstatus.xml SystemUnit TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS SystemUnit: ProductType: ProductId: Uptime: Software: Version: Name: ReleaseDate: Configuration: Telephony: VideoTelephony: TotalBandwidth ISDNBandwidth: LANBandwidth: PresenterOption: True/False MultisiteOption: True/False StreamingSupport: True/False Encryption: True/False Hardware: SerialNumber:...
  • Page 210: Systemunit

    REFERENCE GUIDE FOR SYSTEM INTEGRATORS DataPorts: AudioInputs: Settop: True/False TV-Standard: PAL/NTSC TemperatureCelcius: TemperatureFahrenheit: Example: *s SystemUnit: ProductType: “TANDBERG Codec” ProductId: “TANDBERG 6000MXP PORTABLE” Uptime: 10136 Software: Version: “F4.0Beta2 NTSC” Name: “s50000” ReleaseDate: “2005-11-17” Configuration: Telephony: 5 VideoTelephony: 5 TotalBandwidth: 6144 ISDNBandwidth: 1920 LANBandwidth: 4096...
  • Page 211: Virtualmonitor

    Status Information – xstatus /xstatus.xml VirtualMonitor TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS VirtualMonitor [1..4]: Layout Full / 2Split / 2+1Split / 3+1Split / 4Split / 5+1Split, persistent = On/Off): (type = Window [1..6]: Picture: LocalMain / LocalDuo / Current /Previous / Duo / RemoteMain / RemoteDuo / JPEG / Still / None CallRef: 1..11...
  • Page 212: Warning

    Status Information – xstatus /xstatus.xml Warning TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Warning [1..10] (status = NA / Active) If status = the following will be included: <Nothing> Example: *s Warning 7 (status=NA): / *s/end Active If status =...
  • Page 213: Call

    Status Information – xhistory / xhistory.xml Call TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Call [1..20] type = Tlph Vtlph protocol = ISDN H320 H323 direction = Incoming Outgoing If type = and protocol = and direction = the following will be included: <Nothing>...
  • Page 214: Call - Disconnectcause

    Status Information – xhistory / xhistory.xml Call - DisconnectCause TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS DisconnectCause may show as a result of the xhistory Call command and indicates the reason why the call was disconnected. See Call for an overview of the xhistory Call command.
  • Page 215: Call - Disconnectcausevalues

    Status Information – xhistory / xhistory.xml Call - DisconnectCauseValue (1:3) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS DisconnectCauseValue may show as a result of the xhistory Call com- munication user is temporarily not addressable at any user-network mand and contains additional information to the DisconnectCause result.
  • Page 216 Status Information – xhistory / xhistory.xml Call - DisconnectCauseValue (2:3) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Cause No. 31 - Normal, Unspecified Cause No. 57 - Bearer Capability Not Authorized indicated in the diagnostic. This cause is used to report a normal event only when no other cause in This cause indicates that the user has requested a bearer capability the normal class applies.
  • Page 217 Status Information – xhistory / xhistory.xml Call - DisconnectCauseValue (3:3) TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Cause No. 81 - Invalid Call Reference Value This cause indicates that the equipment sending this cause has equipment sending the cause to process the message.
  • Page 218: Authenticationfailure

    Status Information – xevent /xevent.xml AuthenticationFailure TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS AuthenticationFailure Service: RemoteIPAddress: Uptime: Example: Polling: *e AuthenticationFailure: Service: / RemoteIPAddress: / Uptime: / *e/end Feedback: *e AuthenticationFailure: Service: FTP RemoteIPAddress: “10.47.11.82:1459” Uptime: 417490 *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 –...
  • Page 219: Calldisconnected

    Status Information – xevent /xevent.xml CallDisconnected TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CallDisconnected: CallRef: LogTag: Example: Polling: *e CallDisconnected: CallRef: / LogTag: / *e/end Feedback: *e CallDisconnected: CallRef: 2 LogTag: 11 *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 –...
  • Page 220: Callsuccessful

    Status Information – xevent /xevent.xml CallSuccessful TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS CallSuccessful: CallRef: LogTag: Protocol: Direction: CallRate: RemoteNumber: Encryption: Incoming: Outgoing: Example: Polling: *e CallSuccessful: CallRef: / LogTag: / Protocol: / Direction: / CallRate: / RemoteNumber: /...
  • Page 221: Downspeedingfinished

    Status Information – xevent /xevent.xml DownspeedingFinished TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS DownspeedingFinished: CallRef: LogTag: Rate: Example: Polling: *e DownspeedingFinished: CallRef: / LogTag: / Rate: / *e/end Feedback: *e DownspeedingFinished: CallRef: 3 LogTag: 7 Rate: 384 *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 –...
  • Page 222: Messageboxresult

    Status Information – xevent /xevent.xml MessageBoxResult TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS MessageBoxResult: Button: Example: Polling: *e MessageBoxResult: Button: / *e/end Feedback: *e MessageBoxResult: Button: 1 *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 223: Packetlossdownspeed

    Status Information – xevent /xevent.xml PacketlossDownSpeed TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS PacketlossDownSpeed: CallRef: LogTag: Example: Polling: *e PacketlossDownSpeed: CallRef: / LogTag: / *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 224: Sstring

    Status Information – xevent /xevent.xml SString TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS SString: Example: Polling: *e SString: / *e/end Feedback: *e SString: “Testing SString” *e/end Status information followed by a will not be shown unless Detailed Level has been set to 2 – see XACLI –...
  • Page 225: Systemactivity

    Status Information – xevent /xevent.xml SystemActivity TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS SystemActivity: Service: RemoteIPAddress: Uptime: Description: Example: Polling: *e SystemActivity: Service: / RemoteIPAddress: / Uptime: / Description: / *e/end Feedback: *e SystemActivity: Service: FTP RemoteIPAddress: “Unknown”...
  • Page 226: Controlling External Cameras

    TANDBERG web site regularly for updated control system, and that you want to be able to control versions of this manual: these cameras using the TANDBERG remote or from the http://www.tandberg.com/support/ remote site using FECC (Far End Camera Control). To do documentation.php...
  • Page 227: Extcam Protocol Basics

    If a far end video switch end that you have switched video source with the TANDBERG remote or from the remote site with what you have in your control system. command is received, it will be routed to the your control system.
  • Page 228: Interfacing To The Tandberg Wave Ii Camera

    Interfacing to the TANDBERG WAVE II Camera TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS The TANDBERG WAVE II camera uses a RS-232 control interface responses (messages) have the following format: Command and Response Exchange Sequence that resembles the Sony VISCA protocol.
  • Page 229 Controlling External Cameras > Interfacing to the TANDBERG WAVE II Camera Commands TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Message Comment Autofocus on 81 01 04 38 02 FF Manual focus on 81 01 04 38 03 FF...
  • Page 230 Controlling External Cameras > Interfacing to the TANDBERG WAVE II Camera Commands TANDBERG 3000 & 6000 cont... REFERENCE GUIDE FOR SYSTEM INTEGRATORS Command Message Comment Bright exp on 81 01 04 3E 02 FF Bright exp off 81 01 04 3E 03 FF...
  • Page 231: Connecting To The Camera

    Controlling External Cameras Interfacing to the Precision HD Camera TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS This document describes how to communicate with the Precision Identification Brightness, Iris, Gain HD camera using the VISCA protocol. The Wave 2 interface was...
  • Page 232: Tandberg Video Switch

    HD http://www.tandberg.com/support/ cameras and provides support for third party HD cameras. documentation.php This section of the Reference User Guide explains the TANDBERG Video Switch basics as well as how to set up different daisy chained solutions.
  • Page 233: Unpacking The Video Switch

    Just add them to the chain of cameras in the diagram shown overleaf, 4 Rubber Feet but make sure the added sources appear after the TANDBERG HD Precision cameras in the chain 1 HD Camera cable (1 m) for 6000MXP Codec (i.e.
  • Page 234: Connecting The Video Switch

    Mic.1 Mic.2 DC in Audio out TANDBERG 3000 MXP Codec TANDBERG 6000 MXP Codec DB 9 – RJ 45 To upgrade the software of the Precision HD camera, connect the camera directly to the main camera socket of the Codec (the socket that otherwise is used when connecting the Video Switch to the Codec).
  • Page 235 This diagram shows the additional connections needed to expand from using up to four TANDBERG Precision HD cameras (see previous page) to also include up to three TANDBERG WAVE II cameras (i.e. up to seven cameras in total). Connect Video Switch power supply as shown overleaf.
  • Page 236 Control Control   RCA – RCA RJ 45 – DB 9 SONY Mini DIN Precision HD RJ 11 TANDBERG 6000 MXP Codec 1 DTR 1 GND 2 DSR 2 Not Used 3 TXD 3 TXD Video in PC DVI-I in Audio in 2.
  • Page 237: Installation Of The Video Switch

    To select physical input 3 on the codec, use xconfiguration nected. MainVideoSource: 3, as usual. To see inputs on the switch, select co- Will switch the TANDBERG Video Switch to the given input when the dec input 1 with xconfiguration MainVideoSource: 1 and select switch xcommand CameraReconfigure preset is activated.
  • Page 238: Communicating With The Video Switch

    CAM_Power 8x 01 04 00 0p ff p = 2: Power on. p = 3: Power off. The TANDBERG Video Switch (TVS) uses a RS-232 prefixed with FE 01. Replies from the secondary control interface that resembles the Sony VISCA chain will also be prefixed with FE 01.
  • Page 239: Configuration Commands

    TANDBERG Video Switch Communicating with the Video Switch TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS Configuration Commands Inquiries Messages starting with 8x-01-40-<00..1f> are configuration commands. Messages starting with 8x- 09... Command Command Packet Comments Command set Command Packet...
  • Page 240: Disclaimer And Safety Instructions

    TANDBERG. other hazards, and will void the warranty. Refer all servicing to qualified service personnel. TANDBERG reserves the right to amend any of the information given in Dust this document in order to take account of new developments.
  • Page 241: Product Declaration

    TANDBERG Video Switch Product Declaration TANDBERG 3000 & 6000 REFERENCE GUIDE FOR SYSTEM INTEGRATORS ( A Class product declaration) (We declare here that the subject product is A Class ITE product, and the following statement is clearly marked in the user...
  • Page 242 Philip Pedersens vei 22, 1366 Lysaker, Norway Telephone: +47 67 125 125 Fax: +47 67 125 234 Video: +47 67 117 777 E-mail: tandberg@tandberg.com...

This manual is also suitable for:

Codec 6000 mxp

Table of Contents