Fire detection & alarm system control panel (suitable for twinflexpro control panels from v1.00)

Advertisement

Fire Detection & Alarm System Control Panel
®
(Suitable for TWINFLEX
pro control panels from V1.00)
Control Panel User Guide
(TO BE RETAINED BY THE USER)
26-1028 Issue 2
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GB2426367 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fike GB2426367

  • Page 1 Fire Detection & Alarm System Control Panel ® (Suitable for TWINFLEX pro control panels from V1.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-1028 Issue 2 PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 2 Fike’s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, Fike shall be under no liability whatsoever in respect of such contents.
  • Page 3: Table Of Contents

    ® TWINFLEX pro Control Panel User Guide Contents Introduction.......................... 4 Purpose of the Guide....................4 Definitions ......................... 4 Understanding the Equipment .................. 5 System Configuration ....................6 What to do if ......................6 User Responsibilities ......................7 Introduction ....................... 7 Routine Testing ......................
  • Page 4: Introduction

    ® TWINFLEX pro Control Panel User Guide Introduction Purpose of the Guide This guide is provided to enable the person responsible for the fire alarm system (see Definitions) to operate the system, undertake their responsibilities with regard to testing and maintenance of the system, and to record events and service/maintenance visits.
  • Page 5: Understanding The Equipment

    ® TWINFLEX pro Control Panel User Guide Understanding the Equipment ® What is TWINFLEX pro? ® ® TWINFLEX pro is the name of the range of fire alarm control panels that use the associated TWINFLEX Multipoint devices which together form the fire alarm system installed in the premises. Devices may connected over up to 8 zones, depending on the capacity of the panel.
  • Page 6: System Configuration

    ® TWINFLEX pro Control Panel User Guide System Configuration The detectors and call points are arranged in zones to enable the approximate location of a fire alarm to be identified. The number of zones depends on the size and the layout of the premises, and is limited to 8 zones per control panel.
  • Page 7: User Responsibilities

    ® TWINFLEX pro Control Panel User Guide User Responsibilities Introduction The responsible person is required under BS5839 to undertake certain tasks with respect to the testing and maintenance of the fire alarm system. The responsible person should also ensure that written procedures are in place for the actions to be taken by the occupants in a fire condition, and that staff required to operate the system have received adequate training.
  • Page 8 ® TWINFLEX pro Control Panel User Guide Annual The requirements of the annual test are similar to the quarterly test except that each device on the system should be tested. Different service organisations may undertake device testing on the same visit, ie. One major service and three minor service visits per year, or they may test a percentage of the devices on each visit so that they are all tested within the 12 month period.
  • Page 9: General Operation

    ® TWINFLEX pro Control Panel User Guide General Operation Normal: Controls Enabled LED off At Access Level 1 (Normal), the main Fire Alarm Controls are disabled and the Controls Enabled LED is switched off – see Fire Alarm Controls. Control Panel Front Note : 4 Zone / 8 Zone Panel version shown General Indication LEDs Control Panel Information Window...
  • Page 10: Fire Alarm Controls

    ® TWINFLEX pro Control Panel User Guide Fire Alarm Controls Note : 4 Zone / 8 Zone Panel version shown The main Fire Alarm Controls may be enabled by turning the key switch to the controls enabled position, or by entering a valid Access code. fire alarm controls –...
  • Page 11: Access Levels And Codes

    ® TWINFLEX pro Control Panel User Guide Access Levels and Codes The menu system is divided into four access levels in order to restrict access to those who require it. For simple indication the status of the Controls Enabled light will show the level selected as follows; Access Level Description Controls...
  • Page 12: Silencing The Alarms

    ® TWINFLEX pro Control Panel User Guide Silencing the Alarms When the fire procedures have been carried out and it is safe to silence the alarm, proceed as follows. Enable the controls and then The alarm sounders should silence, but the buzzer and the fire indication lights should remain.
  • Page 13: Led Indication

    ® TWINFLEX pro Control Panel User Guide LED Indication Note : 4 Zone / 8 Zone Panel version shown The operation of the LED indication on the front of the control panel is described below. The LED indication on the panel can also be confirmed by checking the message displayed in the panel information screen or by accessing the relevant event log from the panel menu Description...
  • Page 14 ® TWINFLEX pro Control Panel User Guide SOUNDER Yellow Flashing A fault condition is present on a monitored sounder circuit. Continuous A device or an action associated with the monitored sounder circuits has been disabled. FIRE OUTPUT Yellow Flashing A fault condition is present on a monitored Relay circuit.
  • Page 15: Troubleshooting

    ® TWINFLEX pro Control Panel User Guide Troubleshooting Problem Possible Cause Remedial Action Enter Access Level 2A (User) or Access Unable to silence Panel not in Access Level 2A (User) Level 2B (Supervisor) - see section on alarms or Access Level 2B (Supervisor) operation.
  • Page 16: Advanced Operation

    ® TWINFLEX pro Control Panel User Guide Advanced Operation Access Level 1 (Normal): Controls Enabled LED off At Access Level 1 (Normal), the main Fire Alarm Controls are disabled and the following System Controls will only be accessible if a fire, fault or disablement is active on the panel: NORMAL 1.
  • Page 17: Access Level 2A (User)

    ® TWINFLEX pro Control Panel User Guide Access Level 2A (User): Controls Enabled LED on At Access Level 2A (User), the main Fire Alarm Controls are enabled, and the following System Controls are accessible: USER (8737) 1. View Current Events 1.
  • Page 18 ® TWINFLEX pro Control Panel User Guide 1. View Current Events 4. Current Warnings The Active Log will display any current warnings. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. Press the ESC key to exit the menu.
  • Page 19: Access Level 2B (Supervisor)

    ® TWINFLEX pro Control Panel User Guide Access Level 2B (Supervisor ): Controls Enabled LED flashing slowly At Access Level 2B (Supervisor), the main Fire Alarm Controls are enabled, and the following System Controls are accessible SUPR (7877) 1. View Current Events 1.
  • Page 20 ® TWINFLEX pro Control Panel User Guide 1. View Current Events 1. Current Fires The Active Log will display any current fires. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. Press the ESC key to exit the menu.
  • Page 21 ® TWINFLEX pro Control Panel User Guide 2. Test Modes 1. Test Cntrls & Disp 3. Test Buzzer The Test buzzer function toggles on and off to ensure correct buzzer operation. The test light will illuminate while this action is taken. 2.
  • Page 22 ® TWINFLEX pro Control Panel User Guide 2. Test Modes 2. Test Zone 3. System Test The System Test function allows the entire system to operate in a simple one- man walk test mode. On triggering a device the device LED operates and the event is recorded into the event log, all the assigned sounders operate for 10 seconds and the control panel indicates an alarm.
  • Page 23 ® TWINFLEX pro Control Panel User Guide 3. Enable/ Disable 5. Network Comms This function is not currently available. 4. Set Time and Date This allows the time and date to be adjusted. Use the UP AND DOWN keys to move the cursor between options and the alphanumeric keypad to enter the time and/or date.
  • Page 24: Log Book

    ® TWINFLEX pro Control Panel User Guide LOG BOOK Record all fire and fault events, whether or not an engineer was called Event Log Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 25 ® TWINFLEX pro Control Panel User Guide Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 26 ® TWINFLEX pro Control Panel User Guide Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 27 ® TWINFLEX pro Control Panel User Guide Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 28 ® TWINFLEX pro Control Panel User Guide Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 29 ® TWINFLEX pro Control Panel User Guide Time Zone/Device Event Action Initials PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor...
  • Page 30: Fire Alarm System Notice

    ® TWINFLEX pro Control Panel User Guide FIRE ALARM SYSTEM NOTICE To Enable the Control Panel Keys You may gain access to the fire alarm controls by inserting the key turning ¼ turn or by entering the USER code (default 8737). The ‘Controls Enabled’ LED should then be illuminated.
  • Page 31: Fire Alarm User Notice

    ® TWINFLEX pro Control Panel User Guide FIRE ALARM USER NOTICE Note The Fire alarm system installed in this building has ‘Alarm Confirmation’ technology to help eliminate false alarms. Please read and understand the following information in order to make the most use of the system Operation When the detector within your area activates it will initially only operate the sounders within your...
  • Page 32: Installation Details

    ® TWINFLEX pro Control Panel User Guide Installation Details This section should be completed by the commissioning engineer at handover. Name of Responsible Person: ……….….………………………………………………………..…………. Name and Address of Installation: …………………..……………...………………………………………. .…………………………………………………………….………………………………………………………. Ref. No. (if applicable): ……….………………………………………………………………………………… Date of Handover: ……….…………………………………………………………………………………...