Size E Single Phase Power Installation
Figure 3-14 Size E Single Phase 230/460VAC Power Connections
Single phase 3 wire Connections
L1
Note 1
* Circuit
Breaker
Note 3
A1
B1
*Optional
Note 4
Line
Reactor
A2
B2
Note 3
L1
Series 15H
Control
MN715
Figure 3-13 Jumper Configuration
Place JP1 on the High Voltage Circuit Board across pins 1 and 2.
JP1
Pins 1 & 2 = Single Phase
Pins 2 & 3 = Three Phase
L2
Earth
Notes:
L2
L3
1.
2.
Baldor
3.
4.
1
Single phase 2 wire Connections
L1 Neutral
* Circuit
Breaker
A1
*Line
Reactor
A2
See "Protective Devices" described previously in this section.
Use same gauge wire for Earth ground as is used for L1, L2 and L3.
Metal conduit should be used. Connect conduits so the use of a
Reactor or RC Device does not interrupt EMI/RFI shielding.
See Line/Load Reactors described previously in this section.
See Recommended Tightening Torques in Section 6.
L1
L2
* Fuse
Connection
A1
B1
Note 1
*
Optional components
not provided with control.
Receiving & Installation 3-17