REMOTE CONTROL FUNCTIONS

The remote control is the interface between the user and the
high- -wall systems. Commands are entered by the user to control
the system. Any command that has been entered with the remote
control will remain in the memory until it is changed by the user
or the batteries are replaced.
NOTE: When entering commands, point the remote control in
the direction of the LED display on the front panel. The
will appear for a short period of time on the remote control
when the command is entered. The unit will only emit an
audible beep when the signals are received correctly.
ON/OFF:
Press this button to turn unit on and off.
MODE:
Each time this button is pressed, a mode is selected in a sequence
that goes from AUTO, COOL, DRY, FAN and HEAT*, as shown
below:
AUTO
COOL DRY FAN
NOTE: *Only models with heating function.
AUTO mode is the default setting at start- -up. In AUTO mode, the
set temperature will not e displayed on the LCD, and the unit will
automatically select the suitable operation mode to provide comfort
based on parameters set from the factory.
—:
Press this button once to decrease the setpoint by 1_F. If the button
is pressed for more than two seconds, the setpoint decreases rapidly
in increments of 1_F. In AUTO mode, set temperature is not
adjustable.
+
:
Press this button to increase the setpoint by 1_F. If the button is
pressed for more than two seconds, the setpoint increases rapidly
in increments of 1_F. In AUTO mode, set temperature is not
adjustable.
FAN:
This button is used to set the fan speed in the following sequence
Fan Speeds: Low
:
The horizontal swing button can be used to have the louvers swing
continuously, or to move the louvers to a predetermined position.
To move the louvers continuously:
S
Press
button to start the swing function. Press
again to stop the swing function.
To move the louvers to a predetermined position:
S
Press + button and
unit is off. The
will blink for two seconds.
S
Now, pressing the
louvers to positions shown below.
OPER
HEAT*
Medium
High
button at the same time while the
button changes the horizontal
HEALTH|SAVE:
HEALTH is not available, SAVE is available on unit sizes 18K and
24K.
When SAVE (right- -hand side of button) is pressed, SE is displayed
and the unit goes into SAVE operation mode (set point defaults to
80_F/27_C). Press SAVE button again to cancel function. During
SAVE operation, the temperature and fan speed is not adjustable.
X- -FAN:
Pressing X- -FAN button in COOL or DRY mode will activate the
DRY function and the X- -FAN icon will be displayed. When this
function is activated, the indoor fan will continue to run for 10
minutes in order to dry the indoor coil after the unit is turned off.
X- -FAN is not available in AUTO, FAN and HEAT mode.
TEMP:
The unit will display the set point temperature. Pressing the TEMP
button once will display the room temperature (measured by return
air sensor). After 5 seconds, the set point will be displayed again.
TIMER:
This function will allow the user to set the unit to run for a number
of hours and be off for a number of hours, on a continuous basis.
The time OFF and ON can be set from 0.5 hours to 24 hours in
half hour increments, within a one minute accuracy.
Setting the Timer ON Time:
system OFF, press the "TIMER" button. Within 5 seconds, use the
"+" and "- -" buttons to set the TIMER ON hours. The range of
hours is from 0.5 to 24 hours, in half hour increments. Press the
"TIMER" button again to save the setting.
Setting the Timer OFF Time:
system ON, press the "TIMER" button within 5 seconds, use the
"+" and "- -" button to set the Timer OFF hours. The range of hours
is 0.5 to 24 hours, in half hour increments. Press the "TIMER"
button again to save the setting.
NOTE:
1. Once the Time ON time is set to a number of hours, and
the Time OFF time is set to a number of hours, the system
will operate on and off at those set times. It will continue
until the hours ON and OFF are changed or the timer func-
tion is turned OFF.
2. To Turn OFF timer function, simply press the "TIMER"
button again, clearing the timer function from the remote
control display.
TURBO:
Press this button to activate/deactivate the TURBO function. The
TURBO function enables the unit to reach the set temperature
quicker by running at higher fan speeds.

SLEEP MODE:

This mode is used to conserve energy and can be used when the
unit is in the COOL, HEAT or DRY mode only.
In Cool Mode: Push the SLEEP button. After 1 hour, the set
point will be raised by 1.8_F (1_C). After another hour, the set
point will be raised by another 1.8_F (1_C) and the fan will run
in low speed.
The SLEEP mode will be cancelled when the SLEEP button is
pushed again.
In Heat Mode: Same as cooling mode but set points will be
lowered by 1.8_F (1_C) and the HEAT icon will disappear from
the display panel.
LIGHT:
This function will allow the user to turn the display ON or OFF
on the front panel.
Press the light icon
to turn the indoor unit front panel ON or
OFF. The remote control will display the Light Icon
Combination of "+" and "- -" Buttons:
Press "+" and "- -" buttons simultaneously to lock or unlock the
keypad. If the remote control is locked,
case, pressing any button,
the keypad is unlocked.
7
With the remote control and
With the remote control and
.
is displayed. In this
blinks three times to acknowledge