3-WIRE
SYSTEM
CONNECTIONS
If the power cord has terminals,
place the terminals
over the existing
nuts
on the posts.
The neutral
(white or center wire on power cord) conductor
_3-WireSystem
must always
be connected
to the center (silver colored)
post of the
\ _
terminal
block.
°
Secure
in place using the nuts provided
in the partspackage.
If the
power cord does not have terminals,
use the cupped
washers
ahead of
the nuts.
Be sure the terminal block nuts are tight.
Secure the power cord in position.
Tighten the strain relief screw(s)
in order to clamp the strain relief to the
cord.
Replace
the terminal
block cover.
WARNING:
If converting
from a 4-wire electrical
system
to a 3-wire
the ground strap must be
reconnected
to the term nab
OCKsupport
to ground the aryer frame to the neutra
conauctor.
4-WIRE
SYSTEM
CONNECTIONS
Strain
Remove
the ground strap screw from the terminal
block sup-
port.
Fold the ground strap over so both ends of the ground
strap will be attached
to the center terminal
block post.
Connect
the neutral (white) conductor
of the cord to the center
(silver) post of the terminal
block.
Connect
the grounding
(green) wire of the cord to the terminal
block support
using the
ground strap screw.
Connect
the red and black wires of the cord to the outer posts
of the terminal
block.
Be sure the terminal
block nuts are on tight.
Secure
the power
cord in position.
Tighten the strain relief screw(s)
in order to
clamp the strain relief to the cord.
Replace
the terminal
block
cover.
4-Wire System with
Power Cord Attached
'\j
Folded
Neutral
Ground
VAC
120
VAC
Strain
relief
EXPORT
MODELS
Refer to the Additional
Instructions
Section.
7.
With a level, check the dryer, and make necessary
adjustments
to the level-
ing legs.
Once level, tighten
the leveling
leg locking nuts with a wrench.
8,
The dryer door direction
can be reversed.
1. If the dryer is plugged
in, unplug from electrical
service.
2. Remove
the hinge hole covers
and screws.
Move the door catch cover to the opposite
side.
3. While supporting
the door remove 2 screws
in the hinges that secure the hinges to the cabinet.
4. Remove
the door by lifting slightly
at the hinges and pulling the hinge tabs out of the hinge slots.
5. Move the following
parts to the opposite
side of the door:
2 hinges and 4 hinge screws,
4 door
screws,
door strike and screw, inner door cover plate and screw.
6. Attach the door to the opposite
side of the cabinet
using the 2 counter
sunk hinge screws.
(See below.)
7. Driving the lower hinge screw first will help to align the door and hinges.
8. Replace
the hinge hole covers
and screws
in the opposite
side.
Door Catch
,
'
[,,
,';"'t _..,,,
i
i
i rlJ
i
i
i - _1
IrPi Ili
_
i
i
i
i
_
i
i
i
i
i
i_
i
Counter Sunk Screw _
i
Door
_"Screws
Door
Page 8

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MDE5500AZW and is the answer not in the manual?

Questions and answers

Table of Contents