4) Reset Button
Step 1: Switch off IP device by disconnecting the power cable
Step 2: Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.)
Step 3:
Reconnect the power cable while continuing to hold the reset button.
LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for another second
and turn off again. By this time the reset to default operation is already completed.
around 20 seconds from power up.
fluctuates slightly with the environment. The Power LED light will come back on and stay on after a
few more seconds. The unit will start up with factory default settings automatically.
Power On
On (3s)
5) Conduit Hole
Conduit Holes are openings where
cables pass through. There are two
conduit holes on this device, used
for different mounting angles.
TCM-7411 Hardware User's Manual
You may then release the reset button. This length of time
Off (about 15s)
About 20 Seconds
11
Restore to Default
Complete
On
Off (10~15s)
1s
The red Power
This will take
Stay On
www.acti.com