High Altitude Installations - HearthStone 8160 Owner's Manual

Euro collection gas fired direct-vent heater
Hide thumbs Also See for 8160:
Table of Contents

Advertisement

HearthStone Quality Home Heating Products, Inc.
Figure 14 – Structure Attachment Kit (side
view)
Leave the screws loose. Next, level, then slide the rear or
outer plate up tight to the wall. Using the three screws
provided, screw the steel plate to the wall framing. Once
the screws are in place and the stove is in its proper
location, use the provided allen wrench to tighten the two
screws that hold the two plates together.
H
A
IGH
LTITUDE
For installations
from 610-1370 meters altitude (2000-
4500ft) the orifice sizes (DMS) should be 38 for NG and 53
for LP. See the rating label for more information. For high
altitude installations, consult the local gas distributer or the
authority having jurisdiction for proper rating methods. If
the installer must convert the unit to adjust for varying
altitudes, the information sticker (similar to Figure 15) must
I
NSTALLATIONS
be filled out by the installer and adhered to the appliance at
the time of conversion. (
altitudes compries entre 0 et
seulment).
Figure 15 - Altitude Conversion Sticker
22
LUNO 8160 Gas-Fired Direct-Vent
Cet appareil est equipe pour des
2000pieds (0-610m)