Gas Supply; Installation; Pressure Regulator Location - Electrolux EI30DS55JS1 Installation Instructions Manual

30" dual fuel slide-in range with an electric oven and a gas cooktop
Hide thumbs Also See for EI30DS55JS1:
Table of Contents

Advertisement

Available languages

Available languages

Cabinet
Construction
To eliminate the risk of burns or fire by
reaching over heated surface units, do not have cabinet
storage space above the range. If there is cabinet
storage space above range, reduce risk by installing a
range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinet.
Countertop
Preparation
• The cooktop sides of the range fit over the cutout edge
of your countertop.
• If you have a square finish
(flat) countertop,
no
countertop preparation is required. Cooktop sides lay
directly on edge of countertop.
• Formed front-edged
countertops
must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner
of opening (Figure 7).
• Tile countertops
may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened (Figure 7).
Min.
(1.9 cm)
Cutout
"-_.,.._
_
Width
y_>__
(81 cm)
Formed
or tile
countertop
trimmed
%" (1 9 cm)
back
at
front
corners
of countertop
......
(1 _ cm)
Figure 7
opening.
!
• If the existing
cutout
width
is greater
than
30 1/16"
(76,4
cm),
reduce
the
3A" (1.9
cm)
dimension.
• Countertop
must
be level.
Place a level on the
countertop,
first side to side, then front to back. If the
countertop
is not level, the range will not be level. The
oven must be level for satisfactory
baking
results.
Cooktop
sides of range fit over edges of countertop
opening.
For existing cutout width of 29" (73.7 cm) (Figure 8):
2 3/16"
2 3/16"
_
(5.56 cm)
Gas Supply-
Installation
When shipped from the factory, this unit is designed to
operate on 4"(10,16 cm) water column (1.0 kPa) Natural
gas manifold pressure. A convertible pressure regulator is
connected to the range manifold and MUST be connected
in series with the gas supply line. To access the regulator,
remove the drawer.
For proper
operation,
the maximum inlet pressure to
the regulator should be no more than 14"(35,56 cm) of
water column pressure (3.5 kPa).
The inlet pressure to the regulator must be at least 1 " (.25
kPa) greater than the regulator manifold pressure setting.
The regulator is set for 4"(10,16 cm) water column (1.0
kPa) Natural gas manifold pressure; the inlet pressure must
be at least 5"(12.60 cm) water column (1.25 kPa) Natural
gas. For LP/Propane gas, the regulator must be set for
10"(25,4 cm) water column (2.5 kPa) manifold pressure;
the inlet pressure must be at least 11 "(27,9 cm) water
column (2.75 kPa).
The supply line should be equipped with an approved
shutoff valve (see Figure 11). This valve should be located
in the same room as the range and should be in a location
that allows ease of opening and closing. Do not block
access to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance. Open the shutoff valve in
the gas supply line. Wait a few minutes for gas to move
through the gas line.
The gas supply between the shutoff valve and the regulator
may be connected by rigid piping or by A.G.A./C.G.A.-
approved flexible metallic union-connected piping where
local codes permit use.
The gas supply piping can be through the side wall of the
right cabinet. The right side cabinet is an ideal location for
the main shutoff valve.
Connection
to Pressure
Regulator
The regulator is already installed on the appliance.
Do not make the connection too tight. The
regulator is die cast. Overtightening may crack the regulator
resulting in a gas leak and possible fire or explosion.
3o,,J
(76.2 cm)
311/2"
(80 cm)
k"
Fi_8
Formed
or tile
countertop
trimmed
11/4" (3.2
cm) back at front
corners
of countertop
_-
opening.
PRESSURE REGULATOR LOCATION
Figure 9
I
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents