Cabinet Construction; Countertop Preparation - Frigidaire CFES3025LW5 Installation Instructions Manual

30" electric slide-in range
Hide thumbs Also See for CFES3025LW5:
Table of Contents

Advertisement

Available languages

Available languages

Wherelocal
codes DO NOT permit connecting the
appliance-grounding
conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 7):
1.
Disconnect tile power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
In the circuit breaker, fuse box or junction box:
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit breaker,
fuse box or junction box.
Green (or Bare
Junction
Box
Cable from Residence
Cabinet
Construction
To eliminate tile risk of burns or fire by
reaching over heated surface units, do not have cabinet
storage space above the range. If there is cabinet
storage space above range, reduce risk by installing a
range hood that projects horizontally a minimum of 5"
(1 2.7 cm) beyond the bottom of the cabinet.
_Countertop
Preparation
• The cooktop sides of the range fit over the cutout edge
of your countertop.
• If you have a square finish (flat) countertop,
no
countertop preparation is required. Cooktop sides lay
directly on edge of countertop.
• Formed front-edged
countertops
must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner
of opening (Figure 8).
• Tile countertops
may need trim cut back 3/4"(1.9
cm) from each front corner and!or rounded edge
flattened (Figure 8).
_U.L.-listed
Conduit
Connector (or CSA
(1.9 cm)
Cable from
listed)
j
311/2'_
(81 cm)
Formed or tile countertop
trimmed
%" (1.9 cm) back at
front corners
of countertop
opening.
Figure 8
Appliance
Figure 7 - 4-Wire Electrical
System
(Example: Junction Box)
• If the existing
cutout width
is greater than
30 1116"
(76,4
cm),
reduce
the
3/_,, (19
cm)
dimension.
• Countertop
must
be level.
Place a level on the
countertop,
first side to side, then front to back. If the
countertop
is not level, the range will not be level. The
oven must be level for satisfactory
baking
results.
Cooktop
sides of range fit over edges of countertop
opening
Q_
For
cutout width
of 29"
existing
(73.7 cm) (Figure 9):
2 3/t6"
(5,56
cm)
You must also clear 2 3/16"
(5.56 cm) of material
from
front
of countertop.
tl_
n
.(3,2 cm)
(76.2 cm)
311/2'
J
(81
cm)
JFormed
or tile countertop trimmed 11/4 "
(3.2 cm) back at front corners of
countertop
opening.
1%"
(3.2 cm)
Figure
9

Hide quick links:

Advertisement

Table of Contents
loading